OPS Failing fault.ops.chassis.voltage.fail on FRU /SYS/MB at Component /SYS/MB (18070361)

If you have upgraded the system firmware to version 9.1.1, you might see error messages like the following in the SP log, especially after you power cycle the server.

2014-01-08/23:20:03 ereport.chassis.voltage-unc-ghi@/SYS/MB
                    detector = /SYS/MB/V_+12V_3V3_STBY_OBPS
                    hidden = true
                    reading = 11.9141
                    threshold = 11.844

Additionally, if you use fmdump -eV, you might see an ereport titled ereport.chassis.voltage-unc-ghi@SYS/MB for detector /SYS/MB/V_+12V_3V3_STBY_OBPS.


Caution

Caution  -  Do not power cycle the server if you have removed the power supply in PS0 or if you have removed the power cord from PS0. The server will not boot under these conditions.


Workaround: You can safely ignore these messages and ereports. However, the messages are retained in the SP log.