Installation

About the Installation Procedure

Installation Procedure Overview

Preparing for Server Installation

Server Physical Specifications

Space Requirements

Electrical Power Requirements

Environmental Requirements

Ventilation and Cooling

Agency Compliance

Shipping Inventory

Tools and Equipment Needed for Installation

ESD and Safety Precautions

Optional Component Installation

About Server Features and Components

Server Components

Front Panel Status Indicators, Connectors, and Drives

Back Panel Status Indicators, Connectors, Drives, and PCIe Slots

Server Management Software Overview

Getting Server Firmware and Software Updates

Firmware and Software Updates

Firmware and Software Access Options

Software Releases

Getting Firmware and Software From MOS or PMR

Installing Updates Using Other Methods

Installing the Server Into a Rack

Installation Prerequisites

Rack Requirements

Safety Precautions When Rackmounting the Server

Rackmount Kit Contents

Stabilize the Rack for Installation

Install Mounting Brackets

Mark the Rackmount Location

Attach Tool-less Slide-Rail Assemblies

Install the Server Into the Slide-Rail Assemblies

Install the Second-Generation Cable Management Arm

Remove the Second-Generation Cable Management Arm

Install the First-Generation Cable Management Arm

Verify Operation of Slide-Rails and CMA

Cabling the Server

Rear Cable Connections and Ports

Ethernet Ports

Attaching Data Cables to the Server

Connect the Data Cables

Connecting Power Cords to the Server

Connect the Power Cords

Connecting to Oracle ILOM

Oracle ILOM Hardware and Interfaces

Network Defaults

Logging In to Oracle ILOM Using a Local Serial Connection

Logging In to Oracle ILOM Using a Remote Ethernet Connection

Accessing the Host Console Through Oracle ILOM

Troubleshooting the Service Processor Connection

Setting Up Software and Firmware Using Oracle System Assistant

Accessing Oracle System Assistant

Setting Up Software and Firmware Using Oracle System Assistant

Set Up Software and Firmware Using Oracle System Assistant

Setting Up an Operating System and Drivers

Configuring Server Drives for OS Installation

RAID Configuration Tools

RAID Configuration Requirements

Configuring Storage Drives Into RAID Volumes Using Oracle System Assistant

Configuring RAID Using the BIOS RAID Configuration Utilities

Configuring the Preinstalled Oracle Solaris 11.1 Operating System

Preinstalled Oracle Solaris 11.1 Image BIOS Boot Mode Restriction

Preinstalled Operating System RAID Limitations

Operating System Options

Oracle Solaris 11.1 Configuration Worksheet

Configure the Preinstalled Oracle Solaris 11.1 Operating System

Oracle Solaris 11.1 Operating System Documentation

Configuring the Preinstalled Oracle Linux 6. x Operating System

Preinstalled Oracle Linux Image BIOS Boot Mode Restriction

Oracle Linux 6.x Configuration Worksheet

Configure the Preinstalled Oracle Linux 6.x Operating System

Registering Oracle Linux and Activating Automatic Update

Oracle Linux 6.x Operating System Documentation

Configuring the Preinstalled Oracle VM 3.2 Software

Preinstalled Oracle VM Image BIOS Boot Mode Restriction

Preinstalled Oracle VM Server and Oracle VM Manager Compatibility Requirements

Oracle VM Server Configuration Worksheet

Configure the Preinstalled Oracle VM Server

Updating Oracle VM Software

Oracle VM Documentation

Controlling System Power

Powering Off the Server for Orderly Shutdown

Powering Off the Server for Immediate Shutdown

Reset the Server

Troubleshooting Installation Issues

Installation Troubleshooting

Technical Support Information Worksheet

Locating the System Serial Number

Site Planning Checklists

Preparation Checklists

Oracle Solaris Installation

About Oracle Solaris Operating System Installs

Oracle Solaris OS Installation Task Map

Supported Operating Systems

Selecting the Console Display Option

Selecting the Boot Media Option

Selecting the Installation Target Option

Oracle Solaris OS Installation Options

Oracle System Assistant Overview

Preparing to Install the Operating System

Setting Up BIOS

Configuring RAID

Installing the Oracle Solaris Operating System

Before You Begin

Installing Oracle Solaris on a Single System Using Oracle System Assistant

Installing the Oracle Solaris 10 or 11 Operating System on a Single System Using Media

Oracle VM Installation

About Oracle VM Installs

Oracle VM Installation Task Map

Supported Oracle VM Software

Selecting the Console Display Option

Selecting the Boot Media Option

Selecting the Installation Target Option

Oracle VM Installation Options

Oracle System Assistant Overview

Preparing to Install Oracle VM

Verify the BIOS Factory Defaults

Disable VT-d and SR-IOV in BIOS

Configuring RAID

Installing Oracle VM

Before You Begin

Installing Oracle VM on a Single System Using Oracle System Assistant

Installing Oracle VM on a Single System Using Media

Post Installation Tasks for Oracle VM

Configuring Network Interfaces

NIC Connectors

Linux Installation

About Linux Operating System Installs

Supported Linux Operating Systems

Oracle Unbreakable Enterprise Kernel for Linux

Selecting the Console Display Option

Selecting the Boot Media Option

Selecting the Installation Target Option

Linux OS Installation Options

Oracle System Assistant Overview

Preparing to Install the Operating System

Setting Up BIOS

Configuring RAID

Installing a Linux Operating System

Installing a Linux OS on a Single System Using Oracle System Assistant

Installing Oracle Linux on a Single System Using Media

Installing Red Hat Enterprise Linux on a Single System Using Media

Installing SUSE Linux Enterprise Server on a Single System Using Media

Configuring Network Interfaces

NIC Connectors

Windows Installation

About Microsoft Windows Server Operating System Installs

Windows OS Installation Task Map

Supported Windows Operating Systems

SAS PCIe HBAs Requiring LSI Mass Storage Driver for Windows Server 2008 SP2

Selecting the Console Display Option

Selecting the Boot Media Option

Selecting the Installation Target Option

Windows OS Installation Options

Oracle System Assistant Overview

Preparing to Install the Operating System

Setting Up BIOS

Configuring RAID

Installing a Windows Server Operating System

Before You Begin

Installing Windows Server on a Single System Using Oracle System Assistant

Installing Windows Server on a Single System Using Media

Post Installation Tasks for Windows Server

Supplemental Software Component Options

Installing Device Drivers and Supplemental Software

Configuring Intel NIC Teaming

VMware ESXi Installation

About VMware ESXi Installs

VMware ESXi Installation Task Map

Supported VMware ESXi Software

Selecting the Console Display Option

Selecting the Boot Media Option

Selecting the Installation Target Option

VMware ESXi Installation Options

Preparing to Install VMware ESXi

Setting Up BIOS

Configuring the VMware ESXi 5.0 Software or the Server Hardware to Support Network Connections

Configuring RAID

Installing VMware ESXi

Before You Begin

Installing VMware ESXi on a Single System Using Media

Post Installation Tasks for VMware ESXi

Configure Network Adapter Settings

Determine the MAC Address of a Connected Server Network Port

Update the VMware ESXi Software

Manage VMware ESXi Resources

Configuring Network Interfaces

NIC Connectors

Service

About the Sun Server X4-2L

Product Description

About Controls and Connectors

About Server and Component Status Indicators

About System Components

Troubleshooting the Server

Service Troubleshooting Task List

Diagnostic Tools

Gather Service Information

Locate the Server Serial Number

Inspecting the System

Preparing for Service

Safety Precautions

Safety Symbols

Electrostatic Discharge Safety

FRU TLI Auto-Update

Required Tools

Preparing the Server for Component Replacement

Servicing CRUs That Do Not Require Server Power-Off

Servicing Storage Drives and Rear Drives (CRU)

Servicing Fan Modules (CRU)

Servicing Power Supplies (CRU)

Servicing CRUs That Require Server Power-Off

Servicing the DIMMs (CRU)

Servicing PCIe Cards (CRU)

Servicing the SAS Expander Module (CRU)

Servicing the Air Baffle (CRU)

Servicing the DVD Drive (CRU)

Servicing the Internal USB Flash Drives (CRU)

Servicing the Battery (CRU)

Servicing FRUs

Servicing Processors (FRU)

Selecting the Correct Processor Removal/Replacement Tool

Remove a Processor

Install a Processor

Servicing the Front and Rear Storage Drive Backplanes (FRU)

Remove the Storage Drive Backplane for Eight-Drive and Twelve-Drive Systems

Install the Storage Drive Backplane for Eight-Drive and Twelve-Drive Systems

Remove the Storage Drive Backplane for Twenty-Four Drive Systems

Install the Storage Drive Backplane for Twenty-Four Drive Systems

Remove the Storage Drive Backplane for Rear-Mounted Storage Drives

Install the Storage Drive Backplane for Rear-Mounted Storage Drives

Servicing the Front LED/USB Indicator Modules (FRU)

Remove the Left LED Indicator Module

Install the Left LED Indicator Module

Remove the Right LED/USB Indicator Module

Install the Right LED/USB Indicator Module

Servicing Cables (FRU)

Remove Storage Drive Cables From a SAS/SATA Configuration

Install Storage Drive Cables in a SAS/SATA Configuration

Servicing the Motherboard Assembly (FRU)

Remove the Motherboard Assembly

Install the Motherboard Assembly

Returning the Server to Operation

Server Filler Panel Requirements

Remove and Install Filler Panels

Install the Server Top Cover

Install the Fan Assembly Door

Remove Antistatic Measures

Reinstall the Server Chassis in the Rack

Return the Server to the Normal Rack Position

Reconnect Power and Data Cables

Power On the Server

Identifying the Server Ports

Gigabit-Ethernet Ports

Network Management Port

Serial Management Port

Video Connector

USB Ports

Setting Up BIOS Configuration Parameters

Managing the BIOS Configuration

Accessing the BIOS Setup Utility

Using Legacy or UEFI BIOS

Using BIOS for Resource Allocation

Common BIOS Setup Utility Tasks

BIOS Setup Utility Menu Options

BIOS Main Menu Selections

BIOS Advanced Menu Selections

BIOS IO Menu Selections

BIOS Boot Menu Selections

UEFI Driver Control Menu Selections

BIOS Save & Exit Menu Selections

Monitoring Components and Identifying SNMP Messages

Monitoring Component Health and Faults Using Oracle ILOM

Monitoring System Components

Identifying SNMP Trap Messages

Generic Host Events

Environmental Events

Hard Disk Drive Events

Power Events

Fan Events

Memory Events

Entity Presence Events

Physical Presence Events

Index

Install the Motherboard Assembly

  1. Attach an antistatic wrist strap to your wrist, and then to a metal area on the chassis.

    See Take Antistatic Measures.

  2. Carefully lift and place the motherboard assembly into the chassis [1].

    Tilt the motherboard to the right side to fit under the power supply assembly, level the motherboard and place it into the server chassis, then slide it to the rear of the server to engage the mushroom-shaped standoffs.


    Figure 93 Installing the Motherboard Assembly

    image:Figure showing the motherboard assembly being installed in the server.
  3. Install the mid-wall into the chassis.
    1. Lift and place the mid-wall into the chassis [2].
    2. Using a No. 2 Phillips screwdriver, tighten the four green captive screws that secure the mid-wall to the bottom of the chassis [3].
    3. Using a No. 2 Phillips screwdriver, insert and tighten the two screws on each side of the chassis to secure the mid-wall in the chassis [4].
  4. Reconnect the server intrusion switch cable to the motherboard [5].
  5. Reconnect the signal cable from the storage drive backplane to the motherboard [5].

    See Servicing the Front and Rear Storage Drive Backplanes (FRU).

  6. Reconnect the ribbon cables from left and right LED/USB indicator modules to the motherboard [6].

    See Servicing the Front LED/USB Indicator Modules (FRU).

  7. To reinstall components, follow these instructions:

    Caution

    Caution - When reinstalling power supplies, it is important to reinstall them into the slots from which they were removed during the motherboard removal procedure; otherwise, the server FRU top-level indicator (TLI) data might be lost. When a server requires service, the FRU TLI is used by Oracle to verify that the warranty for the server has not expired. For more information on the server FRU TLI, see FRU TLI Auto-Update.


  8. Return the server to operation.
    1. Install the top cover.

      See Install the Server Top Cover.

    2. Return the server to the normal rack position.

      See Return the Server to the Normal Rack Position.

    3. Reconnect the power cords to the power supplies, and power on the server.

      See Reconnect Power and Data Cables and Power On the Server. Verify that the AC OK LED is lit.


    Note - IMPORTANT: After replacing the motherboard, you might need to manually program the product serial number (PSN) into the new motherboard. This is necessary because the motherboard is a secondary member of a select group of components for maintaining the PSN for service entitlement, and if you replace more than one of the quorum members during any given service procedure, a secondary quorum member might need to be programmed with the PSN.


Related Information