JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Server X4-2 HTML Documentation Collection
search filter icon
search icon

Document Information

Using This Documentation

Getting the Latest Software and Firmware

About This Documentation

Related Documentation

Feedback

Access to Oracle Support

Installation

About the Installation Procedure

Installation Procedure Overview

Preparing for Server Installation

Server Physical Specifications

Space Requirements

Electrical Power Requirements

Environmental Requirements

Ventilation and Cooling

Agency Compliance

Shipping Inventory

Tools and Equipment Needed for Installation

ESD and Safety Precautions

Optional Component Installation

About Server Features and Components

Server Components

Front Panel Status Indicators, Connectors, and Drives

Back Panel Status Indicators, Connectors, and PCIe Slots

Server Management Software Overview

Getting Server Firmware and Software Updates

Firmware and Software Updates

Firmware and Software Access Options

Software Releases

Getting Firmware and Software From MOS or PMR

Installing Updates Using Other Methods

Installing the Server Into a Rack

Installation Prerequisites

Rack Requirements

Safety Precautions When Rackmounting the Server

Rackmount Kit Contents

Stabilize the Rack for Installation

Install Mounting Brackets

Mark the Rackmount Location

Attach Tool-less Slide-Rail Assemblies

Install the Server Into the Slide-Rail Assemblies

Install the Second-Generation Cable Management Arm

Remove the Second-Generation Cable Management Arm

Install the First-Generation Cable Management Arm

Verify Operation of Slide-Rails and CMA

Cabling the Server

Rear Cable Connections and Ports

Ethernet Ports

Attaching Data Cables to the Server

Connecting Power Cords to the Server

Connecting to Oracle ILOM

Oracle ILOM Hardware and Interfaces

Network Defaults

Logging In to Oracle ILOM Using a Local Serial Connection

Logging In to Oracle ILOM Using a Remote Ethernet Connection

Accessing the Host Console Through Oracle ILOM

Troubleshooting the Service Processor Connection

Setting Up Software and Firmware Using Oracle System Assistant

Accessing Oracle System Assistant

Setting Up Software and Firmware Using Oracle System Assistant

Setting Up an Operating System and Drivers

Configuring Server Drives for OS Installation

RAID Configuration Tools

RAID Configuration Requirements

Configuring Storage Drives Into RAID Volumes Using Oracle System Assistant

Configuring RAID Using the BIOS RAID Configuration Utilities

Configuring the Preinstalled Oracle Solaris 11.1 Operating System

Preinstalled Oracle Solaris 11.1 Image BIOS Boot Mode Restriction

Preinstalled Operating System RAID Limitations

Operating System Options

Oracle Solaris 11.1 Configuration Worksheet

Configure the Preinstalled Oracle Solaris 11.1 Operating System

Oracle Solaris 11.1 Operating System Documentation

Configuring the Preinstalled Oracle Linux 6.x Operating System

Preinstalled Oracle Linux Image BIOS Boot Mode Restriction

Oracle Linux 6.x Configuration Worksheet

Configure the Preinstalled Oracle Linux 6.x Operating System

Registering Oracle Linux and Activating Automatic Update

Oracle Linux 6.x Operating System Documentation

Configuring the Preinstalled Oracle VM 3.2 Software

Preinstalled Oracle VM Image BIOS Boot Mode Restriction

Preinstalled Oracle VM Server and Oracle VM Manager Compatibility Requirements

Oracle VM Server Configuration Worksheet

Configure the Preinstalled Oracle VM Server

Updating Oracle VM Software

Oracle VM Documentation

Controlling System Power

Powering Off the Server for Orderly Shutdown

Powering Off the Server for Immediate Shutdown

Reset the Server

Troubleshooting Installation Issues

Installation Troubleshooting

Technical Support Information Worksheet

Locating the System Serial Number

Site Planning Checklists

Preparation Checklists

Oracle Solaris Installation

About Oracle Solaris Operating System Installs

Oracle Solaris OS Installation Task Map

Supported Operating Systems

Selecting the Console Display Option

Selecting the Boot Media Option

Selecting the Installation Target Option

Oracle Solaris OS Installation Options

Oracle System Assistant Overview

Preparing to Install the Operating System

Setting Up BIOS

Configuring RAID

Installing the Oracle Solaris Operating System

Before You Begin

Installing Oracle Solaris on a Single System Using Oracle System Assistant

Installing the Oracle Solaris 10 or 11 Operating System on a Single System Using Media

Oracle VM Installation

About Oracle VM Installs

Oracle VM Installation Task Map

Supported Oracle VM Software

Selecting the Console Display Option

Selecting the Boot Media Option

Selecting the Installation Target Option

Oracle VM Installation Options

Oracle System Assistant Overview

Preparing to Install Oracle VM

Verify the BIOS Factory Defaults

Disable VT-d and SR-IOV in BIOS

Configuring RAID

Installing Oracle VM

Before You Begin

Installing Oracle VM on a Single System Using Oracle System Assistant

Installing Oracle VM on a Single System Using Media

Post Installation Tasks for Oracle VM

Configuring Network Interfaces

NIC Connectors

Linux Installation

About Linux Operating System Installs

Supported Linux Operating Systems

Oracle Unbreakable Enterprise Kernel for Linux

Selecting the Console Display Option

Selecting the Boot Media Option

Selecting the Installation Target Option

Linux OS Installation Options

Oracle System Assistant Overview

Preparing to Install the Operating System

Setting Up BIOS

Configuring RAID

Installing a Linux Operating System

Installing a Linux OS on a Single System Using Oracle System Assistant

Installing Oracle Linux on a Single System Using Media

Installing Red Hat Enterprise Linux on a Single System Using Media

Installing SUSE Linux Enterprise Server on a Single System Using Media

Configuring Network Interfaces

NIC Connectors

Windows Installation

About Microsoft Windows Server Operating System Installs

Windows OS Installation Task Map

Supported Windows Operating Systems

SAS PCIe HBAs Requiring LSI Mass Storage Driver for Windows Server 2008 SP2

Selecting the Console Display Option

Selecting the Boot Media Option

Selecting the Installation Target Option

Windows OS Installation Options

Oracle System Assistant Overview

Preparing to Install the Operating System

Setting Up BIOS

Configuring RAID

Installing a Windows Server Operating System

Before You Begin

Installing Windows Server on a Single System Using Oracle System Assistant

Installing Windows Server on a Single System Using Media

Post Installation Tasks for Windows Server

Supplemental Software Component Options

Installing Device Drivers and Supplemental Software

Configuring Intel NIC Teaming

VMware ESXi Installation

About VMware ESXi Installs

VMware ESXi Installation Task Map

Supported VMware ESXi Software

Selecting the Console Display Option

Selecting the Boot Media Option

Selecting the Installation Target Option

VMware ESXi Installation Options

Preparing to Install VMware ESXi

Setting Up BIOS

Configuring the VMware ESXi 5.0 Software or the Server Hardware to Support Network Connections

Configuring RAID

Installing VMware ESXi

Before You Begin

Installing VMware ESXi on a Single System Using Media

Post Installation Tasks for VMware ESXi

Configure Network Adapter Settings

Determine the MAC Address of a Connected Server Network Port

Update the VMware ESXi Software

Manage VMware ESXi Resources

Configuring Network Interfaces

NIC Connectors

Service

About the Sun Server X4-2

Product Description

About Controls and Connectors

About Server and Component Status Indicators

About System Components

Troubleshooting the Server

Service Troubleshooting Task List

Diagnostic Tools

Gather Service Information

Locate the Server Serial Number

Inspecting the System

Preparing for Service

Safety Precautions

FRU TLI Auto-Update

Safety Symbols

Electrostatic Discharge Safety

Required Tools

Preparing the Server for Component Replacement

Servicing CRUs That Do Not Require Server Power-Off

Servicing Storage Drives (CRU)

Servicing Fan Modules (CRU)

Servicing Power Supplies (CRU)

Servicing CRUs That Require Server Power-Off

CRU Locations

Servicing the DIMMs (CRU)

Servicing PCIe Risers (CRU)

Servicing PCIe Cards (CRU)

Servicing the DVD Drive (CRU)

Servicing the Internal USB Flash Drives (CRU)

Servicing the Battery (CRU)

Servicing FRUs

FRU Locations

Servicing Processors (FRU)

Selecting the Correct Processor Removal/Replacement Tool

Remove a Processor

Install a Processor

Servicing the Disk Backplane (FRU)

Disk Backplane Configurations

Remove the Disk Backplane

Install the Disk Backplane

Servicing the Front Indicator Module (FRU)

Remove the Front Indicator Module

Install the Front Indicator Module

Servicing the Motherboard (FRU)

Remove the Motherboard

Install the Motherboard

Servicing the SAS Cables (FRUs)

Remove Storage Drive SAS Cables

Install Storage Drive SAS Cables

Returning the Server to Operation

Removing and Installing Server Filler Panels

Install the Server Top Cover

Remove Antistatic Measures

Reinstall the Server Chassis Into the Rack

Return the Server to the Normal Rack Position

Reconnect Data Cables and Power Cords

Power On the Server

Identifying the Server Ports

Gigabit Ethernet Ports

Network Management Port

Serial Management Port

Video Connector

USB Ports

Setting Up BIOS Configuration Parameters

Managing the BIOS Configuration

Accessing the BIOS Setup Utility

Using Legacy or UEFI BIOS

Using BIOS for Resource Allocation

Common BIOS Setup Utility Tasks

BIOS Setup Utility Menu Options

BIOS Main Menu Selections

BIOS Advanced Menu Selections

BIOS IO Menu Selections

BIOS Boot Menu Selections

UEFI Driver Control Menu Selections

BIOS Save & Exit Menu Selections

Monitoring Components and Identifying SNMP Messages

Monitoring Component Health and Faults Using Oracle ILOM

Monitoring System Components

Identifying SNMP Trap Messages

Index

Remove a Processor


Caution

Caution - Processors should be removed only by an Oracle qualified service technician.



Caution

Caution - Processor removal and replacement must be done using the correct removal/replacement tool; otherwise, damage might result to the processor or the processor socket. For information on how to select the correct removal/replacement tool, see Selecting the Correct Processor Removal/Replacement Tool.



Caution

Caution - Be careful not to touch the processor socket pins. The processor socket pins are very fragile. A light touch can bend the processor socket pins and damage the board beyond repair. Always use the processor removal/replacement tool to remove and replace the processor.


  1. Prepare the server for service.
    1. Power off the server and disconnect the power cords from the power supplies.

      See Powering Down the Server.

    2. Extend the server to the maintenance position.

      See Extend the Server to the Maintenance Position.

    3. Attach an antistatic wrist strap to your wrist, and then to a metal area on the chassis.

      See Take Antistatic Measures.

    4. Remove the server top cover.

      Remove the Server Top Cover.

  2. Identify the location of the faulty processor by pressing the Fault Remind button on the motherboard.

    Note - When the Fault Remind button is pressed, a LED located next to the Fault Remind button lights green to indicate that there is sufficient voltage present in the fault remind circuit to light any fault LEDs that were lit due to a failure. If this LED fails to light when you press the Fault Remind button, it is likely that the capacitor powering the fault remind circuit has lost its charge. This can happen if the Fault Remind button is pressed for a long time with fault LEDs lit or if power has been removed from the server for more than 15 minutes.


    The processor fault LEDs are located next to the processor(s).

    • If the processor fault LED is off, then the processor is operating properly.

    • If the processor fault LED is on (amber), then the processor is faulty and should be replaced.


      Note - Processor 0 (P0) is on the left side when viewing the server from the front.



    image:Figure showing the location of the processor fault LEDs.
  3. Gently press down on the top of the heatsink to counteract the pressure of the captive spring-loaded screws that secure the heatsink to the motherboard and loosen the four Phillips captive screws in the heatsink for the processor [1].

    Using a No. 2 Phillips screwdriver, turn the screws counterclockwise alternately one and one half turns until they are fully removed.


    image:Figure showing how to remove the heatsink and open the processor ILM assembly.
  4. To separate the heatsink from the top of the processor, gently twist the heatsink left and right, while pulling upward, and then lift off the heatsink and place it upside down on a flat surface [1].

    A thin layer of thermal grease separates the heatsink and the processor. This grease acts as an adhesive.


    Note - Do not allow the thermal grease to contaminate the work space or other components.


  5. Use an alcohol pad to clean the thermal grease from the underside of the heatsink.

    Be careful not to get the thermal grease on your fingers.


    Caution

    Caution - Failure to clean the heatsink prior to removing the processor could result in the accidental contamination of the processor socket or other components. Also, be careful not to get the grease on your fingers as this could result in contamination of components.


  6. Disengage the processor ILM assembly hinge lever on the right side of the processor socket (viewing the server from the front) by pushing down on the lever and moving it to the side away from the processor, and then rotating the lever upward [2].
  7. Disengage the processor ILM assembly load lever on the left side of the processor socket (viewing the server from the front) by pushing down on the lever and moving it to the side away from the processor, and then rotating the lever upward [2].
  8. To lift the processor ILM assembly load plate off of the processor socket, rotate the ILM hinge lever on the right side of the processor toward the closed position (the ILM load plate is lifted up as the hinge lever is lowered toward the closed position) and carefully swing the ILM load plate to the fully open position [3].

    Caution

    Caution - Whenever you remove a processor, you should replace it with another processor and reinstall the processor heatsink; otherwise, the server might overheat due to improper airflow. For instructions for installing a processor, see Install a Processor.


  9. To remove the processor from the processor socket, acquire the correct processor removal/replacement tool and perform the following steps:

    Caution

    Caution - Before removing the processor, ensure that you are using the correct color-coded processor removal/replacement tool. For information on how to select the correct processor removal/replacement tool, see Selecting the Correct Processor Removal/Replacement Tool.


    1. Locate the button in the center of the top of the processor removal/replacement tool and press it to the down position (see Removing a Processor [1]).
    2. Properly position the tool over the processor socket and lower it into place over the processor socket [2].

      To properly position the tool over the processor socket, rotate the tool until the green or pink triangle (depending on which color-coded tool is being used) on the side of the tool is facing the front of the server and it is over the left side of the processor socket when viewing the server from the front.

    3. Press the release lever on the tool to release the center button and engage the processor [3].

      An audible click indicates that the processor is engaged.

    4. Grasp the tool by the sides and remove it from the server [4].
    5. Turn the tool upside down and verify that it contains the processor [5].
    6. While holding the processor tool up side down, press the center button on the tool to release the processor [5].
    7. Carefully grasp the processor by the front and back edges, lift it out of the tool and place it with the circuit side down (the installed orientation) on a clean antistatic mat [6].

      Caution

      Caution - Ensure that the antistatic mat is clean and free of debris; otherwise, the processor pins might be damaged.


    8. Carefully clean the thermal grease off the top of the processor.

      Caution

      Caution - The following figure shows the green color-coded processor removal/replacement tool. If you are removing a 12-core processor, you must use the pink color-coded processor removal/replacement tool; otherwise, damage might result to the processor or the processor socket. For information on how to select the correct processor removal/replacement tool, see Selecting the Correct Processor Removal/Replacement Tool.



      Figure 61 Removing a Processor

      image:Figure showing how to use the processor remove/replace tool to remove the processor.
Related Information