Oracle ASR Fault Coverage for
Storage Products: Virtual Storage Manager (VSM)
E37207-11
This document covers Oracle ASR Solaris fault coverage information for qualified Virtual Storage Manager (VSM) products. Click the links below for details about your specific platform:
Oracle is continuously analyzing and improving the ASR fault rules to enhance the Oracle support experience. This includes adding, modifying and removing rules to focus on actionable events from ASR assets while filtering non-actionable events. ASR is designed to enhance the process of creating and resolving Service Requests and is not a replacement for system monitoring. As such, the ASR fault coverage documents represent specific faults that Oracle can automate, not parts that are monitored. The ASR Manager includes a feature to integrate the ASR Service Request creation event into your existing monitoring system. This is described in the ASR Manager documentation on http://oracle.com/asr ... Documentation.
Rule ID |
Product |
Rule Name |
Source |
Knowledge Link |
Description |
Action |
Severity |
History |
Last Update Date |
Reason |
---|---|---|---|---|---|---|---|---|---|---|
72273 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.2A02_VSM45 |
ILOM |
Not Available |
Fault code: 2A02 - Diagnostics failure during IML |
CASE |
2 |
|
28-Apr-14 |
|
72276 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.2113_VSM45 |
ILOM |
Not Available |
Fault code: 2113 - Incorrect file count in DIR FD. |
CASE |
3 |
|
|
|
72279 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3300_VSM45 |
ILOM |
Not Available |
Fault code: 3300 - The adt timer popped on a write cmd before the adt transfer finished. |
CASE |
3 |
|
|
|
72282 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3330_VSM45 |
ILOM |
Not Available |
Fault code: 3330 - The adt timer popped on a write cmd before the adt transfer finished. |
CASE |
3 |
|
|
|
72285 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3500_VSM45 |
ILOM |
Not Available |
Fault code: 3500 - The DC function has timed out during a read operation and the hardware has been reset. |
CASE |
2 |
|
11-Aug-14 |
|
72291 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3545_VSM45 |
ILOM |
Not Available |
Fault code: 3545 - A compressor-detected channel parity error has occurred on the DC hardware during a write operation. |
CASE |
2 |
|
|
|
72294 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3546_VSM45 |
ILOM |
Not Available |
Fault code: 3546 - FSC3546_DC_WT_VIRT_CRC_ERR_ON_IEA2 |
CASE |
2 |
|
|
|
72300 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3659_VSM45 |
ILOM |
Not Available |
Fault code: 3659 - A Control Bus Check 1 report generated by the Control Bus hardware performing the Check 1 recovery. |
CASE |
2 |
|
|
|
72303 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3663_VSM45 |
ILOM |
Not Available |
Fault code: 3663 - A DRAM leaf failure event was filed by the memory leaf logic and was recovered by ECC logic. |
CASE |
3 |
|
|
|
72306 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3802_VSM45 |
ILOM |
Not Available |
Fault code: 3802 - An IUP received a micro-second counter error interrupt |
CASE |
3 |
|
|
|
72312 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7342_VSM45 |
ILOM |
Not Available |
Fault code: 7342 - New spare count indicates 2 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72315 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7343_VSM45 |
ILOM |
Not Available |
Fault code: 7343 - New spare count indicates 3 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72318 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7344_VSM45 |
ILOM |
Not Available |
Fault code: 7344 - New spare count indicates 4 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72321 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7345_VSM45 |
ILOM |
Not Available |
Fault code: 7345 - New spare count indicates 5 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72324 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7346_VSM45 |
ILOM |
Not Available |
Fault code: 7346 - New spare count indicates 6 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72327 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7347_VSM45 |
ILOM |
Not Available |
Fault code: 7347 - New spare count indicates 7 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72330 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7348_VSM45 |
ILOM |
Not Available |
Fault code: 7348 - New spare count indicates 8 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72333 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7349_VSM45 |
ILOM |
Not Available |
Fault code: 7349 - New spare count indicates 9 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72336 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.734A_VSM45 |
ILOM |
Not Available |
Fault code: 734A - New spare count indicates 10 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72339 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.734B_VSM45 |
ILOM |
Not Available |
Fault code: 734B - New spare count indicates 11 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72342 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.734C_VSM45 |
ILOM |
Not Available |
Fault code: 734C - New spare count indicates 12 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72345 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.734D_VSM45 |
ILOM |
Not Available |
Fault code: 734D - New spare count indicates 13 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72348 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.734E_VSM45 |
ILOM |
Not Available |
Fault code: 734E - New spare count indicates 14 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72351 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.734F_VSM45 |
ILOM |
Not Available |
Fault code: 734F - New spare count indicates 15 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72354 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7350_VSM45 |
ILOM |
Not Available |
Fault code: 7350 - New spare count indicates 16 or more broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72360 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7420_VSM45 |
ILOM |
Not Available |
Fault code: 7420 - When reading data from a power ASIC the data returned failed parity check. |
CASE |
2 |
|
|
|
72363 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7464_VSM45 |
ILOM |
Not Available |
Fault code: 7464 - IXB has detected a bad battery during a battery integrity test. |
CASE |
3 |
|
|
|
72366 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7596_VSM45 |
ILOM |
Not Available |
Fault code: 7596 - FSC 7596 (CAT3) Warm boot, FIP reset |
CASE |
2 |
|
|
|
72369 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.8804_VSM45 |
ILOM |
Not Available |
Fault code: 8804 - The Qlogic ISP2310 reported a system error. |
CASE |
3 |
|
|
|
72372 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.8940_VSM45 |
ILOM |
Not Available |
Fault code: 8940 - The FIP processor reported a fatal error condition by asserting a Critical Interrupt. |
CASE |
3 |
|
|
|
72375 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.305A_VSM45 |
ILOM |
Not Available |
Fault code: 305A - The hardware detects a virtual field CRC error on data received during an ADT read data transfer. |
CASE |
2 |
|
|
|
72378 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.32C0_VSM45 |
ILOM |
Not Available |
Fault code: 32C0 - An ICE CIP memory parity check 2 error was detected. |
CASE |
3 |
|
|
|
72381 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.32CB_VSM45 |
ILOM |
Not Available |
Fault code: 32CB - CIP detected check2 error occurred with recovery code of no recovery. |
CASE |
3 |
|
|
|
72384 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.32CF_VSM45 |
ILOM |
Not Available |
Fault code: 32CF - A CIP detected check2 error occurred and the recovery is to recognize a unit check. |
CASE |
3 |
|
|
|
72387 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.32E0_VSM45 |
ILOM |
Not Available |
Fault code: 32E0 - A CIP detected check2 error occurred and the recovery is to recognize a unit check for a PPRC secondary channel only. |
CASE |
3 |
|
|
|
72390 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.32E4_VSM45 |
ILOM |
Not Available |
Fault code: 32E4 - An VCF4 VIFA4 FPGA Configuration SRAM CRC check 2 error was detected. |
CASE |
3 |
|
|
|
72393 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.389E_VSM45 |
ILOM |
Not Available |
Fault code: 389E - Check 1 recovery hardware was unable to recover from a control bus write failure after retries. |
CASE |
2 |
|
|
|
72396 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.38BE_VSM45 |
ILOM |
Not Available |
Fault code: 38BE - Check 1 recovery hardware was unable to recover from a control bus read failure after retries. |
CASE |
2 |
|
|
|
72399 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.38C3_VSM45 |
ILOM |
Not Available |
Fault code: 38C3 - The address for an access to data memory was not within data memory boundaries. |
CASE |
2 |
|
|
|
72402 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.38DB_VSM45 |
ILOM |
Not Available |
Fault code: 38DB - A data parity error was detected by the PowerPC processor on an access to the L2 cache. |
CASE |
3 |
|
|
|
72405 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3931_VSM45 |
ILOM |
Not Available |
Fault code: 3931 - Hot channel interrupt |
CASE |
2 |
|
|
|
72408 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E00_VSM45 |
ILOM |
Not Available |
Fault code: 3E00 - Drive Declared Broken |
CASE |
3 |
|
|
|
72417 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E40_VSM45 |
ILOM |
Not Available |
Fault code: 3E40 - Conditional Capacity FSC: Production Partition in Subsystem is out of Conditional Capacity. |
CASE |
2 |
|
|
|
72426 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E5F_VSM45 |
ILOM |
Not Available |
Fault code: 3E5F - Spares needed |
CASE |
1 |
|
|
|
72477 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E73_VSM45 |
ILOM |
Not Available |
Fault code: 3E73 - The Emperor Destage Task could not write data to a drive in a Redundancy Group. |
CASE |
3 |
|
|
|
72480 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.72A6_VSM45 |
ILOM |
Not Available |
Fault code: 72A6 - A corrupted version of the config.cfg file was found. |
CASE |
2 |
|
|
|
72483 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.73D8_VSM45 |
ILOM |
Not Available |
Fault code: 73D8 - Drive RTD in maint mode |
CASE |
3 |
|
|
|
72489 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.741F_VSM45 |
ILOM |
Not Available |
Fault code: 741F - During serial communications to an IFES after a preset number of bits are clocked out onto the bus an interrupt is triggered FEP timed out while waiting for this interrupt. |
CASE |
2 |
|
|
|
72492 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.748F_VSM45 |
ILOM |
Not Available |
Fault code: 748F - MON has detected a bad blower in the penguin. |
CASE |
3 |
|
|
|
72495 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.74AF_VSM45 |
ILOM |
Not Available |
Fault code: 74AF - Three of the four Penguin fans are indicating that they are failing. |
CASE |
2 |
|
|
|
72498 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.765F_VSM45 |
ILOM |
Not Available |
Fault code: 765F - Third level recovery has started. Customer data will not be accessible until recovery completes. |
CASE |
2 |
|
|
|
72501 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.776B_VSM45 |
ILOM |
Not Available |
Fault code: 776B - The ISP Maintenance Bus task has detected an IUP which has entered a Double Check 0 state. |
CASE |
2 |
|
|
|
72504 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.776C_VSM45 |
ILOM |
Not Available |
Fault code: 776C - The ISP Maintenance Bus task has detected an IUP which has entered a halted state. |
CASE |
2 |
|
|
|
72510 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.79EE_VSM45 |
ILOM |
Not Available |
Fault code: 79EE - Failed FRU (Fenced) |
CASE |
3 |
|
|
|
72513 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.79F0_VSM45 |
ILOM |
Not Available |
Fault code: 79F0 - Power offline/lost – Region 0 |
CASE |
3 |
|
|
|
72516 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.79F1_VSM45 |
ILOM |
Not Available |
Fault code: 79F1 - Power offline/lost – Region 1 |
CASE |
3 |
|
|
|
72525 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7A50_VSM45 |
ILOM |
Not Available |
Fault code: 7A50 - FSC 7A50 (CAT1): Device Degraded |
CASE |
3 |
|
|
|
72528 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7B22_VSM45 |
ILOM |
Not Available |
Fault code: 7B22 - This is an FSC reserved for automated testing of the PSA task. |
CASE |
2 |
|
|
|
72531 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7B4E_VSM45 |
ILOM |
Not Available |
Fault code: 7B4E - ISP SCSI hard drive 0 has been fenced. |
CASE |
2 |
|
|
|
72534 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7B4F_VSM45 |
ILOM |
Not Available |
Fault code: 7B4F - ISP SCSI hard drive 1 has been fenced. |
CASE |
2 |
|
|
|
72537 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7C24_VSM45 |
ILOM |
Not Available |
Fault code: 7C24 - This power supply is not producing any output. |
CASE |
2 |
|
|
|
72540 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7C54_VSM45 |
ILOM |
Not Available |
Fault code: 7C54 - Used only in failure reports reporting a proc copy switch completed on the new-master and the reason for the switch |
CASE |
3 |
|
|
|
72543 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7C59_VSM45 |
ILOM |
Not Available |
Fault code: 7C59 - The slave ISP is not operational and should be replaced. |
CASE |
2 |
|
|
|
72546 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7E92_VSM45 |
ILOM |
Not Available |
Fault code: 7E92 - The environmental monitoring task has determined that the N_INT power supply failure line from the logic card cage power supply in power zone 0 is no longer supplying power to the system. |
CASE |
2 |
|
|
|
72549 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7E93_VSM45 |
ILOM |
Not Available |
Fault code: 7E93 - The environmental monitoring task has determined that the N_INT power supply failure line from the logic card cage power supply in power zone 1 is no longer supplying power to the system. |
CASE |
2 |
|
|
|
72552 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7E99_VSM45 |
ILOM |
Not Available |
Fault code: 7E99 - PDU shows power supplied to logic card cage power supply fans has tripped a current limiting device. |
CASE |
2 |
|
11-Aug-14 |
|
72555 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7EB1_VSM45 |
ILOM |
Not Available |
Fault code: 7EB1 - The environmental monitoring system indicates that the PDU AC sensor shows that AC is missing in power zone 1 but that the logic card cage power supply in the zone 1 is still showing AC as being present. |
CASE |
2 |
|
|
|
72558 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7EBB_VSM45 |
ILOM |
Not Available |
Fault code: 7EBB - One ISP card senses a bad blower and the other does not. Suspect FRUs - ISP card, blower cable, motherboard. |
CASE |
3 |
|
|
|
72561 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.881D_VSM45 |
ILOM |
Not Available |
Fault code: 881D - The expression for an 'Assert' has evaluated to FALSE. |
CASE |
3 |
|
|
|
72564 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.882B_VSM45 |
ILOM |
Not Available |
Fault code: 882B - This indicates the VFCC detected an error during a Link Buffer transaction. |
CASE |
3 |
|
|
|
72567 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.883B_VSM45 |
ILOM |
Not Available |
Fault code: 883B - The Qlogic ISP2300 responds to a send iu that indicated a FC_TIMEOUT condition. |
CASE |
3 |
|
|
|
72573 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.898B_VSM45 |
ILOM |
Not Available |
Fault code: 898B - A recoverable PPC Machine Check Exception has occurred. |
CASE |
3 |
|
|
|
72576 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.8B01_VSM45 |
ILOM |
Not Available |
Fault code: 8B01 - An error was detected by a FIP and signaled to the IUP via the Check-2 facility. |
CASE |
3 |
|
|
|
72579 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.8E3D_VSM45 |
ILOM |
Not Available |
Fault code: 8E3D - A FIP coldstart occurred and the IUP is taking the one time SNO to capture the FIP statesave. |
CASE |
2 |
|
|
|
72582 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.8E4A_VSM45 |
ILOM |
Not Available |
Fault code: 8E4A - VTDFM has encountered an unrecoverable error in a VTV |
CASE |
2 |
|
|
|
72585 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.8E4B_VSM45 |
ILOM |
Not Available |
Fault code: 8E4B - VTDFM has encountered an unrecoverable error in a VTV. |
CASE |
2 |
|
|
|
72588 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.8FEE_VSM45 |
ILOM |
Not Available |
Fault code: 8FEE - Nearlink ERA handling detected a condition requiring the RTD to be forced offline. |
CASE |
3 |
|
|
|
72591 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.9203_VSM45 |
ILOM |
Not Available |
Fault code: 9203 - Data assurance check |
CASE |
1 |
|
|
|
72597 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.B612_VSM45 |
ILOM |
Not Available |
Fault code: B612 - The CTR function was driving the ADT bus when an error occurred or the CTR function was in use as a slave when it encountered an error that the ADT function on the IFF didn't. |
CASE |
2 |
|
|
|
72600 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.B705_VSM45 |
ILOM |
Not Available |
Fault code: B705 - ESSI received a status packet from the ISF that had an invalid serial number. |
CASE |
3 |
|
|
|
72603 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.B827_VSM45 |
ILOM |
Not Available |
Fault code: B827 - The IFF has sent an Alert Loop Down unsolicited status indicating that the FC Loop is down. |
CASE |
2 |
|
|
|
72606 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.B828_VSM45 |
ILOM |
Not Available |
Fault code: B828 - The IFF has sent an Alert Loop Boot unsolicited status indicating that the FC Loop transitioned to a boot state. |
CASE |
2 |
|
|
|
72609 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.B834_VSM45 |
ILOM |
Not Available |
Fault code: B834 - The IFF has sent an Alert Loop Heartbeat unsolicited status indicating that an IFES has stopped responding to heartbeats sent by the IFF. |
CASE |
2 |
|
|
|
72612 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.B90C_VSM45 |
ILOM |
Not Available |
Fault code: B90C - Failed Drive |
CASE |
3 |
|
|
|
72615 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.B90D_VSM45 |
ILOM |
Not Available |
Fault code: B90D - Failed Drive |
CASE |
3 |
|
|
|
72618 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BA03_VSM45 |
ILOM |
Not Available |
Fault code: BA03 - An IFF card has been asynchronously isolated from the FC loop. |
CASE |
3 |
|
|
|
72621 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BA04_VSM45 |
ILOM |
Not Available |
Fault code: BA04 - Request to fence an FCBE drive because it is present on one FC Loop but bypassed from the other. |
CASE |
3 |
|
|
|
72624 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BA05_VSM45 |
ILOM |
Not Available |
Fault code: BA05 - Failed Drive |
CASE |
3 |
|
|
|
72627 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BA06_VSM45 |
ILOM |
Not Available |
Fault code: BA06 - Failed Drive |
CASE |
3 |
|
|
|
72630 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BA07_VSM45 |
ILOM |
Not Available |
Fault code: BA07 - IFES card failed |
CASE |
2 |
|
|
|
72633 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BA08_VSM45 |
ILOM |
Not Available |
Fault code: BA08 - IFES card failed |
CASE |
2 |
|
|
|
72636 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BA11_VSM45 |
ILOM |
Not Available |
Fault code: BA11 - An IFF has not sent the IUP a Command Buffer Available interrupt within the specified time. |
CASE |
2 |
|
|
|
72639 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BA12_VSM45 |
ILOM |
Not Available |
Fault code: BA12 - An ISF has not returned an abort tag status packet to the IUP within the specified time period. |
CASE |
3 |
|
|
|
72642 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BA13_VSM45 |
ILOM |
Not Available |
Fault code: BA13 - An IFF NMI has occurred that was forced by the IFF's internal hardware error detection circuitry. |
CASE |
3 |
|
|
|
72645 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BA15_VSM45 |
ILOM |
Not Available |
Fault code: BA15 - ESI code received unsolicited status packet from IFF indicating IFF took an NMI. |
CASE |
2 |
|
05-Nov-14 |
|
72648 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BB09_VSM45 |
ILOM |
Not Available |
Fault code: BB09 - ESI timed out waiting for the ISF boot diagnostics to return status. |
CASE |
3 |
|
|
|
72651 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BB0A_VSM45 |
ILOM |
Not Available |
Fault code: BB0A - ESI received bad or corrupt status from the ISF boot diagnostics. |
CASE |
3 |
|
|
|
72654 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BB0C_VSM45 |
ILOM |
Not Available |
Fault code: BB0C - The ISF returned status indicating the boot diagnostic tests failed. |
CASE |
3 |
|
|
|
72660 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.C313_VSM45 |
ILOM |
Not Available |
Fault code: C313 - Device Degraded |
CASE |
2 |
|
|
|
72669 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.D00C_VSM45 |
ILOM |
Not Available |
Fault code: D00C - Failed Drive |
CASE |
3 |
|
|
|
72672 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.D00E_VSM45 |
ILOM |
Not Available |
Fault code: D00E - A FCAL link level IOCB command failed because the target sent or requested less data than expected. |
CASE |
3 |
|
|
|
72675 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.D01B_VSM45 |
ILOM |
Not Available |
Fault code: D01B - Failed Drive |
CASE |
3 |
|
|
|
72678 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.D01D_VSM45 |
ILOM |
Not Available |
Fault code: D01D - Failed Drive |
CASE |
3 |
|
|
|
72681 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.D039_VSM45 |
ILOM |
Not Available |
Fault code: D039 - Failed Drive |
CASE |
3 |
|
|
|
72684 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.D057_VSM45 |
ILOM |
Not Available |
Fault code: D057 - Failed Drive |
CASE |
3 |
|
|
|
72687 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.D075_VSM45 |
ILOM |
Not Available |
Fault code: D075 - Failed Drive |
CASE |
3 |
|
|
|
72690 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.D078_VSM45 |
ILOM |
Not Available |
Fault code: D078 - Failed Drive |
CASE |
3 |
|
|
|
72693 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.D082_VSM45 |
ILOM |
Not Available |
Fault code: D082 - Failed Drive |
CASE |
3 |
|
|
|
72696 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.DC10_VSM45 |
ILOM |
Not Available |
Fault code: DC10 - The IFF hardware reported a fatal error condition by asserting a Critical Interrupt. |
CASE |
3 |
|
|
|
72702 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F301_VSM45 |
ILOM |
Not Available |
Fault code: F301 - The caller of cc_generate_fsc passed in a parameter which indicates that the calling function timed out waiting for a response from cache hardware. |
CASE |
2 |
|
|
|
72705 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F30A_VSM45 |
ILOM |
Not Available |
Fault code: F30A - Analysis of cache status in cc_generate_fsc indicates an ADT Overrun involving backend port occurred |
CASE |
2 |
|
|
|
72708 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F31B_VSM45 |
ILOM |
Not Available |
Fault code: F31B - cc_generate_fsc indicates that an ADT Overrun involving a |
CASE |
3 |
|
|
|
72711 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F31C_VSM45 |
ILOM |
Not Available |
Fault code: F31C - backend port occurred. |
CASE |
2 |
|
|
|
72714 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F31E_VSM45 |
ILOM |
Not Available |
Fault code: F31E - The analysis of cache status and state done in cc_generate_fsc indicates that a link level timeout was detected in the ACPORT MAC. Possible failing FRUs: ACMI, ANV, AVM |
CASE |
2 |
|
|
|
72720 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F401_VSM45 |
ILOM |
Not Available |
Fault code: F401 - ACPORT MAC receive layer has detected a protocol error during reception of a packet. Possible failing FRUs: ACMI, AVM, ANV |
CASE |
2 |
|
|
|
72723 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F403_VSM45 |
ILOM |
Not Available |
Fault code: F403 - ACPORT MAC received a packet out of sequence. Possible failing FRUs: ACMI, AVM, ANV |
CASE |
2 |
|
|
|
72726 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F406_VSM45 |
ILOM |
Not Available |
Fault code: F406 - AMPORT MAC receive layer has detected an invalid CRC for a received packet on a Primary access. |
CASE |
2 |
|
|
|
72729 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F407_VSM45 |
ILOM |
Not Available |
Fault code: F407 - AMPORT MAC receive layer has detected an invalid CRC for a received packet on an Alternate access. |
CASE |
2 |
|
|
|
72732 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F40A_VSM45 |
ILOM |
Not Available |
Fault code: F40A - SDRAM controller associated with the primary cache access detected an uncorrectable EDAC error on a read. |
CASE |
2 |
|
|
|
72735 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F40B_VSM45 |
ILOM |
Not Available |
Fault code: F40B - SDRAM controller associated with the alternate cache access detected an uncorrectable EDAC error on a read. |
CASE |
2 |
|
|
|
72738 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F411_VSM45 |
ILOM |
Not Available |
Fault code: F411 - SDRAM controller associated with the primary cache access detected an LPW error. |
CASE |
2 |
|
|
|
72741 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F4C2_VSM45 |
ILOM |
Not Available |
Fault code: F4C2 - Device Degraded |
CASE |
3 |
|
|
|
72744 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F500_VSM45 |
ILOM |
Not Available |
Fault code: F500 - The caller of cc_generate_pfa passed in a parameter which indicates that the calling function detected a User Handled Check 1 while accessing the ADT count register. |
CASE |
2 |
|
|
|
72747 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F502_VSM45 |
ILOM |
Not Available |
Fault code: F502 - The caller of cc_generate_pfa passed in a parameter which indicates that the calling function detected a User Handled Check 1 while accessing the UPDR register. |
CASE |
2 |
|
|
|
72750 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F520_VSM45 |
ILOM |
Not Available |
Fault code: F520 - The analysis of cache status and state done in cc_generate_fsc indicates that a 1 bit error was detected during a read operation and it was corrected. |
CASE |
3 |
|
|
|
72753 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.32CC_VSM45 |
ILOM |
Not Available |
Fault code: 32CC - Either status frame or command response frame was sent, but the accept command is still pending. |
CASE |
3 |
|
04-Apr-14 |
|
72756 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.33C7_VSM45 |
ILOM |
Not Available |
Fault code: 33C7 - An ICE port selection check 2 error was detected during a write adt. |
CASE |
3 |
|
04-Apr-14 |
|
72759 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3653_VSM45 |
ILOM |
Not Available |
Fault code: 3653 - A failure event was detected in one of the eight ports that receive shared memory write packets. |
CASE |
3 |
|
04-Apr-14 |
|
72762 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.38B0_VSM45 |
ILOM |
Not Available |
Fault code: 38B0 - chk0 occurred, shared memory access was attempted when interface was fenced due to content error. |
CASE |
3 |
|
04-Apr-14 |
|
72765 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.71C7_VSM45 |
ILOM |
Not Available |
Fault code: 71C7 - packet stream or an operational port detected an incorrect sequence of headers and content words. |
CASE |
3 |
|
04-Apr-14 |
|
72768 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.74D9_VSM45 |
ILOM |
Not Available |
Fault code: 74D9 - FIML detected that the IUP boot code halted and there is no status data in the FIFO. |
CASE |
3 |
|
04-Apr-14 |
|
72771 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.74DD_VSM45 |
ILOM |
Not Available |
Fault code: 74DD - FIML has received an failure message from the IUP boot code. The FIFO will contain error status. |
CASE |
3 |
|
04-Apr-14 |
|
72774 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7503_VSM45 |
ILOM |
Not Available |
Fault code: 7503 - FIML did not receive a response to the establish communications message. |
CASE |
3 |
|
04-Apr-14 |
|
72777 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.75B3_VSM45 |
ILOM |
Not Available |
Fault code: 75B3 - A device interface card failed an unfence due to a hardware error returned by VFN to FEN. |
CASE |
3 |
|
04-Apr-14 |
|
72783 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7C5A_VSM45 |
ILOM |
Not Available |
Fault code: 7C5A - The alternate ISP has taken a fatal error. |
CASE |
3 |
|
04-Apr-14 |
|
72786 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7E98_VSM45 |
ILOM |
Not Available |
Fault code: 7E98 - Power to logic card cage power supply fans has tripped a current limiting device within the PDU. |
CASE |
3 |
|
04-Apr-14 |
|
72789 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7EA7_VSM45 |
ILOM |
Not Available |
Fault code: 7EA7 - The PDU on side 1 shows that thermal switch 1, on the IHP card, is closed. |
CASE |
3 |
|
04-Apr-14 |
|
72792 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.8844_VSM45 |
ILOM |
Not Available |
Fault code: 8844 - An SB-2 CRC error was detected during an ADT write operation. |
CASE |
3 |
|
04-Apr-14 |
|
72795 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BA0B_VSM45 |
ILOM |
Not Available |
Fault code: BA0B - IFF card failed ESI controlled restart after having NMI or similar prob. Most likely IFF HW prob. |
CASE |
3 |
|
04-Apr-14 |
|
72798 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.D034_VSM45 |
ILOM |
Not Available |
Fault code: D034 - This indicates that at the end of a data sector the CRC remainders are not zero (CRC Check 0). |
CASE |
3 |
|
04-Apr-14 |
|
72810 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.38BB_VSM45 |
ILOM |
Not Available |
Fault code: 38BB - Bus transaction stalled for a period between one and two of the intervals programmed. |
CASE |
3 |
|
04-Apr-14 |
|
72813 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.8635_VSM45 |
ILOM |
Not Available |
Fault code: 8635 - Check 1: Attempt to access a region of the address space at which no memory or registers reside. |
CASE |
3 |
|
04-Apr-14 |
|
72816 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.8AFF_VSM45 |
ILOM |
Not Available |
Fault code: 8AFF - FSC8XXX_FIP_HIGH |
CASE |
3 |
|
04-Apr-14 |
|
72819 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F31D_VSM45 |
ILOM |
Not Available |
Fault code: F31D - Cache status in cc_generate_fsc indicates invalid node number via the \"Alternate\" memory card path. |
CASE |
3 |
|
04-Apr-14 |
|
72822 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.9571_VSM45 |
ILOM |
Not Available |
Fault code: 9571 - none |
CASE |
3 |
|
04-Apr-14 |
|
72825 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.32C1_VSM45 |
ILOM |
Not Available |
Fault code: 32C1 - ICE ECB address parity check 2 error was detected. |
CASE |
3 |
|
04-Apr-14 |
|
72828 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.38EA_VSM45 |
ILOM |
Not Available |
Fault code: 38EA - FSC38EA_PROC_DETECTED_L1_DATA_CACHE_ERROR |
CASE |
3 |
|
04-Apr-14 |
|
72831 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.DC33_VSM45 |
ILOM |
Not Available |
Fault code: DC33 - none |
CASE |
3 |
|
04-Apr-14 |
|
72834 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F30C_VSM45 |
ILOM |
Not Available |
Fault code: F30C - Cache status in cc_generate_fsc indicates that ADT Underrun involving a backend port occurred. |
CASE |
3 |
|
04-Apr-14 |
|
72837 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F402_VSM45 |
ILOM |
Not Available |
Fault code: F402 - ACPORT MAC receive layer has detected an invalid CRC for a received packet. |
CASE |
3 |
|
04-Apr-14 |
|
72840 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F410_VSM45 |
ILOM |
Not Available |
Fault code: F410 - SDRAM controller associated with the primary cache access detected an LPW error. |
CASE |
3 |
|
04-Apr-14 |
|
72843 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F480_VSM6 |
ILOM |
Not Available |
Fault code: F480 - none |
CASE |
3 |
|
04-Apr-14 |
|
72846 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F489_VSM45 |
ILOM |
Not Available |
Fault code: F489 - none |
CASE |
3 |
|
04-Apr-14 |
|
72849 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F582_VSM45 |
ILOM |
Not Available |
Fault code: F582 - none |
CASE |
3 |
|
04-Apr-14 |
|
72852 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.9900_VSM45 |
ILOM |
Not Available |
Fault code: 9900 - IUP initiated offload request to send a MEM to offload this debug data in the corresponding \"T\" file |
CASE |
3 |
|
04-Apr-14 |
|
72855 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.210D_VSM45 |
ILOM |
Not Available |
Fault code: 210D - Indicates a file descriptor (FD) is marked in use, is NOT being used by any file in any directory. |
CASE |
3 |
|
28-Apr-14 |
|
72858 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.776A_VSM45 |
ILOM |
Not Available |
Fault code: 776A - All Maintenance Bus paths from a particular ISP have fenced. GFR of ISP is needed. |
CASE |
2 |
|
28-Apr-14 |
|
79744 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3657_VSM45 |
ILOM |
Not Available |
Fault code: 3657 - A failure event was detected when either the cache data or the cache tag data had bad parity. |
CASE |
2 |
|
|
|
79747 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.38E9_VSM45 |
ILOM |
Not Available |
Fault code: 38E9 - PROC DETECTED L1 INST CACHE ERROR |
CASE |
3 |
|
23-Sep-15 |
|
79750 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E60_VSM45 |
ILOM |
Not Available |
Fault code: 3E60 - Spares Alert FSC: No Useable Spares in Subsystem. |
CASE |
2 |
|
|
|
79753 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F400_VSM45 |
ILOM |
Not Available |
Fault code: F400 - Connection Request Word received by ACPORT MAC receive layer did not have BREAK bit set, which indicates that the packet was truncated. |
CASE |
2 |
|
|
|
79756 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7600_VSM45 |
ILOM |
Not Available |
Fault code: 7600 - An ISP has detected a Check 0 occurred during a Warm Boot. |
CASE |
3 |
|
04-Apr-14 |
|
79759 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F305_VSM45 |
ILOM |
Not Available |
Fault code: F305 - Analysis of cache status and state indicates major ACMI Card problems (ACMI Internal Error). |
CASE |
3 |
|
04-Apr-14 |
|
79762 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F306_VSM45 |
ILOM |
Not Available |
Fault code: F306 - Analysis of cache status and state indicates ADT Parity Error involving the frontend port occurred. |
CASE |
3 |
|
04-Apr-14 |
|
79765 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.F307_VSM45 |
ILOM |
Not Available |
Fault code: F307 - Analysis of cache status and state indicates ADT Parity Error involving the backend port occurred. |
CASE |
3 |
|
04-Apr-14 |
|
72507 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.79A5_VSM45 |
ILOM |
Not Available |
Fault code: 79A5 - Log overflow |
COMPLEX |
3 |
Modified |
27-May-14 |
|
76203 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.73F8_VSM45 |
ILOM |
Not Available |
Fault code: 73F8 - The ISP has detected that the amount of ISP disk space available has reached a minimum threshold of either less that 30Mb or less than 200 file handles left. |
COMPLEX |
3 |
Modified |
10-Aug-15 |
|
72288 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3509_VSM45 |
ILOM |
Not Available |
Fault code: 3509 - A virtual field CRC error has occurred on the decompressor CRC checker during a read operation. |
NO_CASE |
|
|
11-Aug-14 |
|
72309 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7341_VSM45 |
ILOM |
Not Available |
Fault code: 7341 - New spare count indicates 1 broken drives exist in the subsystem at this time. |
NO_CASE |
|
|
|
|
72357 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7358_VSM45 |
ILOM |
Not Available |
Fault code: 7358 - 90 day code notice |
NO_CASE |
|
|
|
|
72411 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E01_VSM45 |
ILOM |
Not Available |
Fault code: 3E01 - Broken Drive is being Reconstructed (started). |
NO_CASE |
|
|
|
|
72414 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E02_VSM45 |
ILOM |
Not Available |
Fault code: 3E02 - Broken Drive has completed Reconstruction. |
NO_CASE |
|
|
|
|
72420 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E41_VSM45 |
ILOM |
Not Available |
Fault code: 3E41 - Conditional Capacity FSC: Production Partition Conditional Capacity Low Threshold Reached. |
NO_CASE |
|
|
|
|
72423 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E42_VSM45 |
ILOM |
Not Available |
Fault code: 3E42 - Conditional Capacity FSC: Production Partition Conditional Capacity Low Threshold Reached. |
NO_CASE |
|
|
|
|
72432 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E61_VSM45 |
ILOM |
Not Available |
Fault code: 3E61 - Spares Alert FSC: 1 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72435 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E62_VSM45 |
ILOM |
Not Available |
Fault code: 3E62 - Spares Alert FSC: 2 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72438 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E63_VSM45 |
ILOM |
Not Available |
Fault code: 3E63 - Spares Alert FSC: 3 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72441 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E64_VSM45 |
ILOM |
Not Available |
Fault code: 3E64 - Spares Alert FSC: 4 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72444 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E65_VSM45 |
ILOM |
Not Available |
Fault code: 3E65 - Spares Alert FSC: 5 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72447 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E66_VSM45 |
ILOM |
Not Available |
Fault code: 3E66 - Spares Alert FSC: 6 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72450 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E67_VSM45 |
ILOM |
Not Available |
Fault code: 3E67 - Spares Alert FSC: 7 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72453 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E68_VSM45 |
ILOM |
Not Available |
Fault code: 3E68 - Spares Alert FSC: 8 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72456 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E69_VSM45 |
ILOM |
Not Available |
Fault code: 3E69 - Spares Alert FSC: 9 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72459 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E6A_VSM45 |
ILOM |
Not Available |
Fault code: 3E6A - Spares Alert FSC: 10 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72462 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E6B_VSM45 |
ILOM |
Not Available |
Fault code: 3E6B - Spares Alert FSC: 11 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72465 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E6C_VSM45 |
ILOM |
Not Available |
Fault code: 3E6C - Spares Alert FSC: 12 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72468 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E6D_VSM45 |
ILOM |
Not Available |
Fault code: 3E6D - Spares Alert FSC: 13 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72471 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E6E_VSM45 |
ILOM |
Not Available |
Fault code: 3E6E - Spares Alert FSC: 14 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72474 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.3E6F_VSM45 |
ILOM |
Not Available |
Fault code: 3E6F - Spares Alert FSC: 15 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72519 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7A00_VSM45 |
ILOM |
Not Available |
Fault code: 7A00 - Power back online – Region 0 |
NO_CASE |
|
|
|
|
72522 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.7A01_VSM45 |
ILOM |
Not Available |
Fault code: 7A01 - Power back online – Region 0 |
NO_CASE |
|
|
|
|
72570 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.88A0_VSM45 |
ILOM |
Not Available |
Fault code: 88A0 - A Virtual Field CRC error was detected during an ADT read operation |
NO_CASE |
|
|
|
|
72594 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.9501_VSM45 |
ILOM |
Not Available |
Fault code: 9501 - Host link HW error detected causing link reset & host access terminated. Link recovered & restarted. |
NO_CASE |
|
|
11-Aug-14 |
|
72657 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.C210_VSM45 |
ILOM |
Not Available |
Fault code: C210 - Not in FSC dictionary |
NO_CASE |
|
|
28-Apr-14 |
|
72663 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.C5A2_VSM45 |
ILOM |
Not Available |
Fault code: C5A2 - Not in FSC dictionary |
NO_CASE |
|
|
28-Apr-14 |
|
72666 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.C611_VSM45 |
ILOM |
Not Available |
Fault code: C611 - Not in FSC dictionary,diagnostic code only |
NO_CASE |
|
|
11-Aug-14 |
|
72699 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.DC11_VSM45 |
ILOM |
Not Available |
Fault code: DC11 - Not in FSC dictionary,diagnostic code only |
NO_CASE |
|
|
11-Aug-14 |
|
72861 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.ASRM.BB05_VSM45 |
ILOM |
Not Available |
Fault code: BB05 - ISF returned status indicating the Control Store RAM test failed. Unfence of the ISF was failed. |
NO_CASE |
|
|
28-Apr-14 |
|
49222 |
VSM4,VSM5 |
79A5 Add to SR |
79A5 Add to SR |
|
For each FSC79A5 event, first check if open SR for same serial and for 79A5-> If open SR found, append event info to open SR and exit-> If no open SR, check for any previous 79A5 events within past 7 days--> If no previous events in past 7 days, ignore event (do not create SR), and exit--> If one or more previous events in past 7 days, open SR and transfer to TSC, and exit |
DATA_PROCESSING |
|
|
|
|
49223 |
VSM4,VSM5 |
79A5 srclosed |
79A5 srclosed |
|
For each FSC79A5 event, first check if open SR for same serial and for 79A5-> If open SR found, append event info to open SR and exit-> If no open SR, check for any previous 79A5 events within past 7 days--> If no previous events in past 7 days, ignore event (do not create SR), and exit--> If one or more previous events in past 7 days, open SR and transfer to TSC, and exit |
DATA_PROCESSING |
|
|
|
|
Rule ID |
Product |
Rule Name |
Source |
Knowledge Link |
Description |
Action |
Severity |
History |
Last Update Date |
Reason |
---|---|---|---|---|---|---|---|---|---|---|
72271 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.2A02_VSM45 |
SDP |
Not Available |
Fault code: 2A02 - Diagnostics failure during IML |
CASE |
2 |
|
28-Apr-14 |
|
72274 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.2113_VSM45 |
SDP |
Not Available |
Fault code: 2113 - Incorrect file count in DIR FD. |
CASE |
3 |
|
|
|
72277 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3300_VSM45 |
SDP |
Not Available |
Fault code: 3300 - The adt timer popped on a write cmd before the adt transfer finished. |
CASE |
3 |
|
|
|
72280 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3330_VSM45 |
SDP |
Not Available |
Fault code: 3330 - The adt timer popped on a write cmd before the adt transfer finished. |
CASE |
3 |
|
|
|
72283 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3500_VSM45 |
SDP |
Not Available |
Fault code: 3500 - The DC function has timed out during a read operation and the hardware has been reset. |
CASE |
2 |
|
11-Aug-14 |
|
72289 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3545_VSM45 |
SDP |
Not Available |
Fault code: 3545 - A compressor-detected channel parity error has occurred on the DC hardware during a write operation. |
CASE |
2 |
|
|
|
72292 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3546_VSM45 |
SDP |
Not Available |
Fault code: 3546 - FSC3546_DC_WT_VIRT_CRC_ERR_ON_IEA2 |
CASE |
2 |
|
|
|
72295 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3657_VSM45 |
SDP |
Not Available |
Fault code: 3657 - A failure event was detected when either the cache data or the cache tag data had bad parity. |
CASE |
2 |
|
|
|
72298 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3659_VSM45 |
SDP |
Not Available |
Fault code: 3659 - A Control Bus Check 1 report generated by the Control Bus hardware performing the Check 1 recovery. |
CASE |
2 |
|
|
|
72301 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3663_VSM45 |
SDP |
Not Available |
Fault code: 3663 - A DRAM leaf failure event was filed by the memory leaf logic and was recovered by ECC logic. |
CASE |
3 |
|
|
|
72304 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3802_VSM45 |
SDP |
Not Available |
Fault code: 3802 - An IUP received a micro-second counter error interrupt |
CASE |
3 |
|
|
|
72310 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7342_VSM45 |
SDP |
Not Available |
Fault code: 7342 - New spare count indicates 2 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72313 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7343_VSM45 |
SDP |
Not Available |
Fault code: 7343 - New spare count indicates 3 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72316 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7344_VSM45 |
SDP |
Not Available |
Fault code: 7344 - New spare count indicates 4 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72319 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7345_VSM45 |
SDP |
Not Available |
Fault code: 7345 - New spare count indicates 5 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72322 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7346_VSM45 |
SDP |
Not Available |
Fault code: 7346 - New spare count indicates 6 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72325 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7347_VSM45 |
SDP |
Not Available |
Fault code: 7347 - New spare count indicates 7 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72328 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7348_VSM45 |
SDP |
Not Available |
Fault code: 7348 - New spare count indicates 8 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72331 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7349_VSM45 |
SDP |
Not Available |
Fault code: 7349 - New spare count indicates 9 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72334 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.734A_VSM45 |
SDP |
Not Available |
Fault code: 734A - New spare count indicates 10 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72337 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.734B_VSM45 |
SDP |
Not Available |
Fault code: 734B - New spare count indicates 11 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72340 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.734C_VSM45 |
SDP |
Not Available |
Fault code: 734C - New spare count indicates 12 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72343 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.734D_VSM45 |
SDP |
Not Available |
Fault code: 734D - New spare count indicates 13 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72346 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.734E_VSM45 |
SDP |
Not Available |
Fault code: 734E - New spare count indicates 14 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72349 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.734F_VSM45 |
SDP |
Not Available |
Fault code: 734F - New spare count indicates 15 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72352 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7350_VSM45 |
SDP |
Not Available |
Fault code: 7350 - New spare count indicates 16 or more broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72358 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7420_VSM45 |
SDP |
Not Available |
Fault code: 7420 - When reading data from a power ASIC the data returned failed parity check. |
CASE |
2 |
|
|
|
72361 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7464_VSM45 |
SDP |
Not Available |
Fault code: 7464 - IXB has detected a bad battery during a battery integrity test. |
CASE |
3 |
|
|
|
72364 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7596_VSM45 |
SDP |
Not Available |
Fault code: 7596 - FSC 7596 (CAT3) Warm boot, FIP reset |
CASE |
2 |
|
|
|
72367 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.8804_VSM45 |
SDP |
Not Available |
Fault code: 8804 - The Qlogic ISP2310 reported a system error. |
CASE |
3 |
|
|
|
72370 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.8940_VSM45 |
SDP |
Not Available |
Fault code: 8940 - The FIP processor reported a fatal error condition by asserting a Critical Interrupt. |
CASE |
3 |
|
|
|
72373 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.305A_VSM45 |
SDP |
Not Available |
Fault code: 305A - The hardware detects a virtual field CRC error on data received during an ADT read data transfer. |
CASE |
2 |
|
|
|
72376 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.32C0_VSM45 |
SDP |
Not Available |
Fault code: 32C0 - An ICE CIP memory parity check 2 error was detected. |
CASE |
3 |
|
|
|
72379 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.32CB_VSM45 |
SDP |
Not Available |
Fault code: 32CB - CIP detected check2 error occurred with recovery code of no recovery. |
CASE |
3 |
|
|
|
72382 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.32CF_VSM45 |
SDP |
Not Available |
Fault code: 32CF - A CIP detected check2 error occurred and the recovery is to recognize a unit check. |
CASE |
3 |
|
|
|
72385 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.32E0_VSM45 |
SDP |
Not Available |
Fault code: 32E0 - A CIP detected check2 error occurred and the recovery is to recognize a unit check for a PPRC secondary channel only. |
CASE |
3 |
|
|
|
72388 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.32E4_VSM45 |
SDP |
Not Available |
Fault code: 32E4 - An VCF4 VIFA4 FPGA Configuration SRAM CRC check 2 error was detected. |
CASE |
3 |
|
|
|
72391 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.389E_VSM45 |
SDP |
Not Available |
Fault code: 389E - Check 1 recovery hardware was unable to recover from a control bus write failure after retries. |
CASE |
2 |
|
|
|
72394 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.38BE_VSM45 |
SDP |
Not Available |
Fault code: 38BE - Check 1 recovery hardware was unable to recover from a control bus read failure after retries. |
CASE |
2 |
|
|
|
72397 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.38C3_VSM45 |
SDP |
Not Available |
Fault code: 38C3 - The address for an access to data memory was not within data memory boundaries. |
CASE |
2 |
|
|
|
72400 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.38DB_VSM45 |
SDP |
Not Available |
Fault code: 38DB - A data parity error was detected by the PowerPC processor on an access to the L2 cache. |
CASE |
3 |
|
|
|
72403 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3931_VSM45 |
SDP |
Not Available |
Fault code: 3931 - Hot channel interrupt |
CASE |
2 |
|
|
|
72406 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E00_VSM45 |
SDP |
Not Available |
Fault code: 3E00 - Drive Declared Broken |
CASE |
3 |
|
|
|
72415 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E40_VSM45 |
SDP |
Not Available |
Fault code: 3E40 - Conditional Capacity FSC: Production Partition in Subsystem is out of Conditional Capacity. |
CASE |
2 |
|
|
|
72424 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E5F_VSM45 |
SDP |
Not Available |
Fault code: 3E5F - Spares needed |
CASE |
1 |
|
|
|
72427 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E60_VSM45 |
SDP |
Not Available |
Fault code: 3E60 - Spares Alert FSC: No Useable Spares in Subsystem. |
CASE |
2 |
|
|
|
72475 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E73_VSM45 |
SDP |
Not Available |
Fault code: 3E73 - The Emperor Destage Task could not write data to a drive in a Redundancy Group. |
CASE |
3 |
|
|
|
72478 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.72A6_VSM45 |
SDP |
Not Available |
Fault code: 72A6 - A corrupted version of the config.cfg file was found. |
CASE |
2 |
|
|
|
72481 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.73D8_VSM45 |
SDP |
Not Available |
Fault code: 73D8 - Drive RTD in maint mode |
CASE |
3 |
|
|
|
72484 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.73F8_VSM45 |
SDP |
Not Available |
Fault code: 73F8 - The ISP has detected that the amount of ISP disk space available has reached a minimum threshold of either less that 30Mb or less than 200 file handles left. |
CASE |
3 |
|
|
|
72487 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.741F_VSM45 |
SDP |
Not Available |
Fault code: 741F - During serial communications to an IFES after a preset number of bits are clocked out onto the bus an interrupt is triggered FEP timed out while waiting for this interrupt. |
CASE |
2 |
|
|
|
72490 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.748F_VSM45 |
SDP |
Not Available |
Fault code: 748F - MON has detected a bad blower in the penguin. |
CASE |
3 |
|
|
|
72493 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.74AF_VSM45 |
SDP |
Not Available |
Fault code: 74AF - Three of the four Penguin fans are indicating that they are failing. |
CASE |
2 |
|
|
|
72496 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.765F_VSM45 |
SDP |
Not Available |
Fault code: 765F - Third level recovery has started. Customer data will not be accessible until recovery completes. |
CASE |
2 |
|
|
|
72499 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.776B_VSM45 |
SDP |
Not Available |
Fault code: 776B - The ISP Maintenance Bus task has detected an IUP which has entered a Double Check 0 state. |
CASE |
2 |
|
|
|
72502 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.776C_VSM45 |
SDP |
Not Available |
Fault code: 776C - The ISP Maintenance Bus task has detected an IUP which has entered a halted state. |
CASE |
2 |
|
|
|
72508 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.79EE_VSM45 |
SDP |
Not Available |
Fault code: 79EE - Failed FRU (Fenced) |
CASE |
3 |
|
|
|
72511 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.79F0_VSM45 |
SDP |
Not Available |
Fault code: 79F0 - Power offline/lost – Region 0 |
CASE |
3 |
|
|
|
72514 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.79F1_VSM45 |
SDP |
Not Available |
Fault code: 79F1 - Power offline/lost – Region 1 |
CASE |
3 |
|
|
|
72523 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7A50_VSM45 |
SDP |
Not Available |
Fault code: 7A50 - FSC 7A50 (CAT1): Device Degraded |
CASE |
3 |
|
|
|
72526 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7B22_VSM45 |
SDP |
Not Available |
Fault code: 7B22 - This is an FSC reserved for automated testing of the PSA task. |
CASE |
2 |
|
|
|
72529 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7B4E_VSM45 |
SDP |
Not Available |
Fault code: 7B4E - ISP SCSI hard drive 0 has been fenced. |
CASE |
2 |
|
|
|
72532 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7B4F_VSM45 |
SDP |
Not Available |
Fault code: 7B4F - ISP SCSI hard drive 1 has been fenced. |
CASE |
2 |
|
|
|
72535 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7C24_VSM45 |
SDP |
Not Available |
Fault code: 7C24 - This power supply is not producing any output. |
CASE |
2 |
|
|
|
72538 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7C54_VSM45 |
SDP |
Not Available |
Fault code: 7C54 - Used only in failure reports reporting a proc copy switch completed on the new-master and the reason for the switch |
CASE |
3 |
|
|
|
72541 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7C59_VSM45 |
SDP |
Not Available |
Fault code: 7C59 - The slave ISP is not operational and should be replaced. |
CASE |
2 |
|
|
|
72544 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7E92_VSM45 |
SDP |
Not Available |
Fault code: 7E92 - The environmental monitoring task has determined that the N_INT power supply failure line from the logic card cage power supply in power zone 0 is no longer supplying power to the system. |
CASE |
2 |
|
|
|
72547 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7E93_VSM45 |
SDP |
Not Available |
Fault code: 7E93 - The environmental monitoring task has determined that the N_INT power supply failure line from the logic card cage power supply in power zone 1 is no longer supplying power to the system. |
CASE |
2 |
|
|
|
72550 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7E99_VSM45 |
SDP |
Not Available |
Fault code: 7E99 - PDU shows power supplied to logic card cage power supply fans has tripped a current limiting device. |
CASE |
2 |
|
11-Aug-14 |
|
72553 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7EB1_VSM45 |
SDP |
Not Available |
Fault code: 7EB1 - The environmental monitoring system indicates that the PDU AC sensor shows that AC is missing in power zone 1 but that the logic card cage power supply in the zone 1 is still showing AC as being present. |
CASE |
2 |
|
|
|
72556 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7EBB_VSM45 |
SDP |
Not Available |
Fault code: 7EBB - One ISP card senses a bad blower and the other does not. Suspect FRUs - ISP card, blower cable, motherboard. |
CASE |
3 |
|
|
|
72559 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.881D_VSM45 |
SDP |
Not Available |
Fault code: 881D - The expression for an 'Assert' has evaluated to FALSE. |
CASE |
3 |
|
|
|
72562 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.882B_VSM45 |
SDP |
Not Available |
Fault code: 882B - This indicates the VFCC detected an error during a Link Buffer transaction. |
CASE |
3 |
|
|
|
72565 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.883B_VSM45 |
SDP |
Not Available |
Fault code: 883B - The Qlogic ISP2300 responds to a send iu that indicated a FC_TIMEOUT condition. |
CASE |
3 |
|
|
|
72571 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.898B_VSM45 |
SDP |
Not Available |
Fault code: 898B - A recoverable PPC Machine Check Exception has occurred. |
CASE |
3 |
|
|
|
72574 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.8B01_VSM45 |
SDP |
Not Available |
Fault code: 8B01 - An error was detected by a FIP and signaled to the IUP via the Check-2 facility. |
CASE |
3 |
|
|
|
72577 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.8E3D_VSM45 |
SDP |
Not Available |
Fault code: 8E3D - A FIP coldstart occurred and the IUP is taking the one time SNO to capture the FIP statesave. |
CASE |
2 |
|
|
|
72580 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.8E4A_VSM45 |
SDP |
Not Available |
Fault code: 8E4A - VTDFM has encountered an unrecoverable error in a VTV |
CASE |
2 |
|
|
|
72583 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.8E4B_VSM45 |
SDP |
Not Available |
Fault code: 8E4B - VTDFM has encountered an unrecoverable error in a VTV. |
CASE |
2 |
|
|
|
72586 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.8FEE_VSM45 |
SDP |
Not Available |
Fault code: 8FEE - Nearlink ERA handling detected a condition requiring the RTD to be forced offline. |
CASE |
3 |
|
|
|
72589 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.9203_VSM45 |
SDP |
Not Available |
Fault code: 9203 - Data assurance check |
CASE |
1 |
|
|
|
72595 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.B612_VSM45 |
SDP |
Not Available |
Fault code: B612 - The CTR function was driving the ADT bus when an error occurred or the CTR function was in use as a slave when it encountered an error that the ADT function on the IFF didn't. |
CASE |
2 |
|
|
|
72598 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.B705_VSM45 |
SDP |
Not Available |
Fault code: B705 - ESSI received a status packet from the ISF that had an invalid serial number. |
CASE |
3 |
|
|
|
72601 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.B827_VSM45 |
SDP |
Not Available |
Fault code: B827 - The IFF has sent an Alert Loop Down unsolicited status indicating that the FC Loop is down. |
CASE |
2 |
|
|
|
72604 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.B828_VSM45 |
SDP |
Not Available |
Fault code: B828 - The IFF has sent an Alert Loop Boot unsolicited status indicating that the FC Loop transitioned to a boot state. |
CASE |
2 |
|
|
|
72607 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.B834_VSM45 |
SDP |
Not Available |
Fault code: B834 - The IFF has sent an Alert Loop Heartbeat unsolicited status indicating that an IFES has stopped responding to heartbeats sent by the IFF. |
CASE |
2 |
|
|
|
72610 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.B90C_VSM45 |
SDP |
Not Available |
Fault code: B90C - Failed Drive |
CASE |
3 |
|
|
|
72613 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.B90D_VSM45 |
SDP |
Not Available |
Fault code: B90D - Failed Drive |
CASE |
3 |
|
|
|
72616 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BA03_VSM45 |
SDP |
Not Available |
Fault code: BA03 - An IFF card has been asynchronously isolated from the FC loop. |
CASE |
3 |
|
|
|
72619 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BA04_VSM45 |
SDP |
Not Available |
Fault code: BA04 - Request to fence an FCBE drive because it is present on one FC Loop but bypassed from the other. |
CASE |
3 |
|
|
|
72622 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BA05_VSM45 |
SDP |
Not Available |
Fault code: BA05 - Failed Drive |
CASE |
3 |
|
|
|
72625 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BA06_VSM45 |
SDP |
Not Available |
Fault code: BA06 - Failed Drive |
CASE |
3 |
|
|
|
72628 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BA07_VSM45 |
SDP |
Not Available |
Fault code: BA07 - IFES card failed |
CASE |
2 |
|
|
|
72631 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BA08_VSM45 |
SDP |
Not Available |
Fault code: BA08 - IFES card failed |
CASE |
2 |
|
|
|
72634 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BA11_VSM45 |
SDP |
Not Available |
Fault code: BA11 - An IFF has not sent the IUP a Command Buffer Available interrupt within the specified time. |
CASE |
2 |
|
|
|
72637 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BA12_VSM45 |
SDP |
Not Available |
Fault code: BA12 - An ISF has not returned an abort tag status packet to the IUP within the specified time period. |
CASE |
3 |
|
|
|
72640 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BA13_VSM45 |
SDP |
Not Available |
Fault code: BA13 - An IFF NMI has occurred that was forced by the IFF's internal hardware error detection circuitry. |
CASE |
3 |
|
|
|
72643 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BA15_VSM45 |
SDP |
Not Available |
Fault code: BA15 - ESI code received unsolicited status packet from IFF indicating IFF took an NMI. |
CASE |
2 |
|
05-Nov-14 |
|
72646 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BB09_VSM45 |
SDP |
Not Available |
Fault code: BB09 - ESI timed out waiting for the ISF boot diagnostics to return status. |
CASE |
3 |
|
|
|
72649 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BB0A_VSM45 |
SDP |
Not Available |
Fault code: BB0A - ESI received bad or corrupt status from the ISF boot diagnostics. |
CASE |
3 |
|
|
|
72652 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BB0C_VSM45 |
SDP |
Not Available |
Fault code: BB0C - The ISF returned status indicating the boot diagnostic tests failed. |
CASE |
3 |
|
|
|
72658 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.C313_VSM45 |
SDP |
Not Available |
Fault code: C313 - Device Degraded |
CASE |
2 |
|
|
|
72667 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.D00C_VSM45 |
SDP |
Not Available |
Fault code: D00C - Failed Drive |
CASE |
3 |
|
|
|
72670 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.D00E_VSM45 |
SDP |
Not Available |
Fault code: D00E - A FCAL link level IOCB command failed because the target sent or requested less data than expected. |
CASE |
3 |
|
|
|
72673 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.D01B_VSM45 |
SDP |
Not Available |
Fault code: D01B - Failed Drive |
CASE |
3 |
|
|
|
72676 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.D01D_VSM45 |
SDP |
Not Available |
Fault code: D01D - Failed Drive |
CASE |
3 |
|
|
|
72679 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.D039_VSM45 |
SDP |
Not Available |
Fault code: D039 - Failed Drive |
CASE |
3 |
|
|
|
72682 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.D057_VSM45 |
SDP |
Not Available |
Fault code: D057 - Failed Drive |
CASE |
3 |
|
|
|
72685 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.D075_VSM45 |
SDP |
Not Available |
Fault code: D075 - Failed Drive |
CASE |
3 |
|
|
|
72688 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.D078_VSM45 |
SDP |
Not Available |
Fault code: D078 - Failed Drive |
CASE |
3 |
|
|
|
72691 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.D082_VSM45 |
SDP |
Not Available |
Fault code: D082 - Failed Drive |
CASE |
3 |
|
|
|
72694 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.DC10_VSM45 |
SDP |
Not Available |
Fault code: DC10 - The IFF hardware reported a fatal error condition by asserting a Critical Interrupt. |
CASE |
3 |
|
|
|
72700 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F301_VSM45 |
SDP |
Not Available |
Fault code: F301 - The caller of cc_generate_fsc passed in a parameter which indicates that the calling function timed out waiting for a response from cache hardware. |
CASE |
2 |
|
|
|
72703 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F30A_VSM45 |
SDP |
Not Available |
Fault code: F30A - Analysis of cache status in cc_generate_fsc indicates an ADT Overrun involving backend port occurred |
CASE |
2 |
|
|
|
72706 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F31B_VSM45 |
SDP |
Not Available |
Fault code: F31B - cc_generate_fsc indicates that an ADT Overrun involving a |
CASE |
3 |
|
|
|
72709 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F31C_VSM45 |
SDP |
Not Available |
Fault code: F31C - backend port occurred. |
CASE |
2 |
|
|
|
72712 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F31E_VSM45 |
SDP |
Not Available |
Fault code: F31E - The analysis of cache status and state done in cc_generate_fsc indicates that a link level timeout was detected in the ACPORT MAC. Possible failing FRUs: ACMI, ANV, AVM |
CASE |
2 |
|
|
|
72715 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F400_VSM45 |
SDP |
Not Available |
Fault code: F400 - Connection Request Word received by ACPORT MAC receive layer did not have BREAK bit set, which indicates that the packet was truncated. |
CASE |
2 |
|
|
|
72718 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F401_VSM45 |
SDP |
Not Available |
Fault code: F401 - ACPORT MAC receive layer has detected a protocol error during reception of a packet. Possible failing FRUs: ACMI, AVM, ANV |
CASE |
2 |
|
|
|
72721 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F403_VSM45 |
SDP |
Not Available |
Fault code: F403 - ACPORT MAC received a packet out of sequence. Possible failing FRUs: ACMI, AVM, ANV |
CASE |
2 |
|
|
|
72724 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F406_VSM45 |
SDP |
Not Available |
Fault code: F406 - AMPORT MAC receive layer has detected an invalid CRC for a received packet on a Primary access. |
CASE |
2 |
|
|
|
72727 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F407_VSM45 |
SDP |
Not Available |
Fault code: F407 - AMPORT MAC receive layer has detected an invalid CRC for a received packet on an Alternate access. |
CASE |
2 |
|
|
|
72730 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F40A_VSM45 |
SDP |
Not Available |
Fault code: F40A - SDRAM controller associated with the primary cache access detected an uncorrectable EDAC error on a read. |
CASE |
2 |
|
|
|
72733 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F40B_VSM45 |
SDP |
Not Available |
Fault code: F40B - SDRAM controller associated with the alternate cache access detected an uncorrectable EDAC error on a read. |
CASE |
2 |
|
|
|
72736 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F411_VSM45 |
SDP |
Not Available |
Fault code: F411 - SDRAM controller associated with the primary cache access detected an LPW error. |
CASE |
2 |
|
|
|
72739 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F4C2_VSM45 |
SDP |
Not Available |
Fault code: F4C2 - Device Degraded |
CASE |
3 |
|
|
|
72742 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F500_VSM45 |
SDP |
Not Available |
Fault code: F500 - The caller of cc_generate_pfa passed in a parameter which indicates that the calling function detected a User Handled Check 1 while accessing the ADT count register. |
CASE |
2 |
|
|
|
72745 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F502_VSM45 |
SDP |
Not Available |
Fault code: F502 - The caller of cc_generate_pfa passed in a parameter which indicates that the calling function detected a User Handled Check 1 while accessing the UPDR register. |
CASE |
2 |
|
|
|
72748 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F520_VSM45 |
SDP |
Not Available |
Fault code: F520 - The analysis of cache status and state done in cc_generate_fsc indicates that a 1 bit error was detected during a read operation and it was corrected. |
CASE |
3 |
|
|
|
72751 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.32CC_VSM45 |
SDP |
Not Available |
Fault code: 32CC - Either status frame or command response frame was sent, but the accept command is still pending. |
CASE |
3 |
|
04-Apr-14 |
|
72754 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.33C7_VSM45 |
SDP |
Not Available |
Fault code: 33C7 - An ICE port selection check 2 error was detected during a write adt. |
CASE |
3 |
|
04-Apr-14 |
|
72757 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3653_VSM45 |
SDP |
Not Available |
Fault code: 3653 - A failure event was detected in one of the eight ports that receive shared memory write packets. |
CASE |
3 |
|
04-Apr-14 |
|
72760 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.38B0_VSM45 |
SDP |
Not Available |
Fault code: 38B0 - chk0 occurred, shared memory access was attempted when interface was fenced due to content error. |
CASE |
3 |
|
04-Apr-14 |
|
72763 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.71C7_VSM45 |
SDP |
Not Available |
Fault code: 71C7 - packet stream or an operational port detected an incorrect sequence of headers and content words. |
CASE |
3 |
|
04-Apr-14 |
|
72766 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.74D9_VSM45 |
SDP |
Not Available |
Fault code: 74D9 - FIML detected that the IUP boot code halted and there is no status data in the FIFO. |
CASE |
3 |
|
04-Apr-14 |
|
72769 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.74DD_VSM45 |
SDP |
Not Available |
Fault code: 74DD - FIML has received an failure message from the IUP boot code. The FIFO will contain error status. |
CASE |
3 |
|
04-Apr-14 |
|
72772 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7503_VSM45 |
SDP |
Not Available |
Fault code: 7503 - FIML did not receive a response to the establish communications message. |
CASE |
3 |
|
04-Apr-14 |
|
72775 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.75B3_VSM45 |
SDP |
Not Available |
Fault code: 75B3 - A device interface card failed an unfence due to a hardware error returned by VFN to FEN. |
CASE |
3 |
|
04-Apr-14 |
|
72778 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7600_VSM45 |
SDP |
Not Available |
Fault code: 7600 - An ISP has detected a Check 0 occurred during a Warm Boot. |
CASE |
3 |
|
04-Apr-14 |
|
72781 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7C5A_VSM45 |
SDP |
Not Available |
Fault code: 7C5A - The alternate ISP has taken a fatal error. |
CASE |
3 |
|
04-Apr-14 |
|
72784 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7E98_VSM45 |
SDP |
Not Available |
Fault code: 7E98 - Power to logic card cage power supply fans has tripped a current limiting device within the PDU. |
CASE |
3 |
|
04-Apr-14 |
|
72787 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7EA7_VSM45 |
SDP |
Not Available |
Fault code: 7EA7 - The PDU on side 1 shows that thermal switch 1, on the IHP card, is closed. |
CASE |
3 |
|
04-Apr-14 |
|
72790 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.8844_VSM45 |
SDP |
Not Available |
Fault code: 8844 - An SB-2 CRC error was detected during an ADT write operation. |
CASE |
3 |
|
04-Apr-14 |
|
72793 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BA0B_VSM45 |
SDP |
Not Available |
Fault code: BA0B - IFF card failed ESI controlled restart after having NMI or similar prob. Most likely IFF HW prob. |
CASE |
3 |
|
04-Apr-14 |
|
72796 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.D034_VSM45 |
SDP |
Not Available |
Fault code: D034 - This indicates that at the end of a data sector the CRC remainders are not zero (CRC Check 0). |
CASE |
3 |
|
04-Apr-14 |
|
72799 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F305_VSM45 |
SDP |
Not Available |
Fault code: F305 - Analysis of cache status and state indicates major ACMI Card problems (ACMI Internal Error). |
CASE |
3 |
|
04-Apr-14 |
|
72802 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F306_VSM45 |
SDP |
Not Available |
Fault code: F306 - Analysis of cache status and state indicates ADT Parity Error involving the frontend port occurred. |
CASE |
3 |
|
04-Apr-14 |
|
72805 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F307_VSM45 |
SDP |
Not Available |
Fault code: F307 - Analysis of cache status and state indicates ADT Parity Error involving the backend port occurred. |
CASE |
3 |
|
04-Apr-14 |
|
72808 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.38BB_VSM45 |
SDP |
Not Available |
Fault code: 38BB - Bus transaction stalled for a period between one and two of the intervals programmed. |
CASE |
3 |
|
04-Apr-14 |
|
72811 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.8635_VSM45 |
SDP |
Not Available |
Fault code: 8635 - Check 1: Attempt to access a region of the address space at which no memory or registers reside. |
CASE |
3 |
|
04-Apr-14 |
|
72814 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.8AFF_VSM45 |
SDP |
Not Available |
Fault code: 8AFF - FSC8XXX_FIP_HIGH |
CASE |
3 |
|
04-Apr-14 |
|
72817 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F31D_VSM45 |
SDP |
Not Available |
Fault code: F31D - Cache status in cc_generate_fsc indicates invalid node number via the \"Alternate\" memory card path. |
CASE |
3 |
|
04-Apr-14 |
|
72820 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.9571_VSM45 |
SDP |
Not Available |
Fault code: 9571 - none |
CASE |
3 |
|
04-Apr-14 |
|
72823 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.32C1_VSM45 |
SDP |
Not Available |
Fault code: 32C1 - ICE ECB address parity check 2 error was detected. |
CASE |
3 |
|
04-Apr-14 |
|
72826 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.38EA_VSM45 |
SDP |
Not Available |
Fault code: 38EA - FSC38EA_PROC_DETECTED_L1_DATA_CACHE_ERROR |
CASE |
3 |
|
04-Apr-14 |
|
72829 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.DC33_VSM45 |
SDP |
Not Available |
Fault code: DC33 - none |
CASE |
3 |
|
04-Apr-14 |
|
72832 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F30C_VSM45 |
SDP |
Not Available |
Fault code: F30C - Cache status in cc_generate_fsc indicates that ADT Underrun involving a backend port occurred. |
CASE |
3 |
|
04-Apr-14 |
|
72835 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F402_VSM45 |
SDP |
Not Available |
Fault code: F402 - ACPORT MAC receive layer has detected an invalid CRC for a received packet. |
CASE |
3 |
|
04-Apr-14 |
|
72838 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F410_VSM45 |
SDP |
Not Available |
Fault code: F410 - SDRAM controller associated with the primary cache access detected an LPW error. |
CASE |
3 |
|
04-Apr-14 |
|
72841 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F480_VSM6 |
SDP |
Not Available |
Fault code: F480 - none |
CASE |
3 |
|
04-Apr-14 |
|
72844 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F489_VSM45 |
SDP |
Not Available |
Fault code: F489 - none |
CASE |
3 |
|
04-Apr-14 |
|
72847 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.F582_VSM45 |
SDP |
Not Available |
Fault code: F582 - none |
CASE |
3 |
|
04-Apr-14 |
|
72850 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.9900_VSM45 |
SDP |
Not Available |
Fault code: 9900 - IUP initiated offload request to send a MEM to offload this debug data in the corresponding \"T\" file |
CASE |
3 |
|
04-Apr-14 |
|
72853 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.210D_VSM45 |
SDP |
Not Available |
Fault code: 210D - Indicates a file descriptor (FD) is marked in use, is NOT being used by any file in any directory. |
CASE |
3 |
|
28-Apr-14 |
|
72856 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.776A_VSM45 |
SDP |
Not Available |
Fault code: 776A - All Maintenance Bus paths from a particular ISP have fenced. GFR of ISP is needed. |
CASE |
2 |
|
28-Apr-14 |
|
72505 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.79A5_VSM45 |
SDP |
Not Available |
Fault code: 79A5 - Log overflow |
COMPLEX |
3 |
Modified |
27-May-14 |
|
72286 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3509_VSM45 |
SDP |
Not Available |
Fault code: 3509 - A virtual field CRC error has occurred on the decompressor CRC checker during a read operation. |
NO_CASE |
|
|
11-Aug-14 |
|
72307 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7341_VSM45 |
SDP |
Not Available |
Fault code: 7341 - New spare count indicates 1 broken drives exist in the subsystem at this time. |
NO_CASE |
|
|
|
|
72355 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7358_VSM45 |
SDP |
Not Available |
Fault code: 7358 - 90 day code notice |
NO_CASE |
|
|
|
|
72409 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E01_VSM45 |
SDP |
Not Available |
Fault code: 3E01 - Broken Drive is being Reconstructed (started). |
NO_CASE |
|
|
|
|
72412 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E02_VSM45 |
SDP |
Not Available |
Fault code: 3E02 - Broken Drive has completed Reconstruction. |
NO_CASE |
|
|
|
|
72418 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E41_VSM45 |
SDP |
Not Available |
Fault code: 3E41 - Conditional Capacity FSC: Production Partition Conditional Capacity Low Threshold Reached. |
NO_CASE |
|
|
|
|
72421 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E42_VSM45 |
SDP |
Not Available |
Fault code: 3E42 - Conditional Capacity FSC: Production Partition Conditional Capacity Low Threshold Reached. |
NO_CASE |
|
|
|
|
72430 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E61_VSM45 |
SDP |
Not Available |
Fault code: 3E61 - Spares Alert FSC: 1 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72433 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E62_VSM45 |
SDP |
Not Available |
Fault code: 3E62 - Spares Alert FSC: 2 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72436 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E63_VSM45 |
SDP |
Not Available |
Fault code: 3E63 - Spares Alert FSC: 3 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72439 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E64_VSM45 |
SDP |
Not Available |
Fault code: 3E64 - Spares Alert FSC: 4 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72442 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E65_VSM45 |
SDP |
Not Available |
Fault code: 3E65 - Spares Alert FSC: 5 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72445 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E66_VSM45 |
SDP |
Not Available |
Fault code: 3E66 - Spares Alert FSC: 6 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72448 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E67_VSM45 |
SDP |
Not Available |
Fault code: 3E67 - Spares Alert FSC: 7 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72451 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E68_VSM45 |
SDP |
Not Available |
Fault code: 3E68 - Spares Alert FSC: 8 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72454 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E69_VSM45 |
SDP |
Not Available |
Fault code: 3E69 - Spares Alert FSC: 9 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72457 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E6A_VSM45 |
SDP |
Not Available |
Fault code: 3E6A - Spares Alert FSC: 10 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72460 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E6B_VSM45 |
SDP |
Not Available |
Fault code: 3E6B - Spares Alert FSC: 11 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72463 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E6C_VSM45 |
SDP |
Not Available |
Fault code: 3E6C - Spares Alert FSC: 12 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72466 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E6D_VSM45 |
SDP |
Not Available |
Fault code: 3E6D - Spares Alert FSC: 13 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72469 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E6E_VSM45 |
SDP |
Not Available |
Fault code: 3E6E - Spares Alert FSC: 14 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72472 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.3E6F_VSM45 |
SDP |
Not Available |
Fault code: 3E6F - Spares Alert FSC: 15 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72517 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7A00_VSM45 |
SDP |
Not Available |
Fault code: 7A00 - Power back online – Region 0 |
NO_CASE |
|
|
|
|
72520 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.7A01_VSM45 |
SDP |
Not Available |
Fault code: 7A01 - Power back online – Region 0 |
NO_CASE |
|
|
|
|
72568 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.88A0_VSM45 |
SDP |
Not Available |
Fault code: 88A0 - A Virtual Field CRC error was detected during an ADT read operation |
NO_CASE |
|
|
|
|
72592 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.9501_VSM45 |
SDP |
Not Available |
Fault code: 9501 - Host link HW error detected causing link reset & host access terminated. Link recovered & restarted. |
NO_CASE |
|
|
11-Aug-14 |
|
72655 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.C210_VSM45 |
SDP |
Not Available |
Fault code: C210 - Not in FSC dictionary |
NO_CASE |
|
|
28-Apr-14 |
|
72661 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.C5A2_VSM45 |
SDP |
Not Available |
Fault code: C5A2 - Not in FSC dictionary |
NO_CASE |
|
|
28-Apr-14 |
|
72664 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.C611_VSM45 |
SDP |
Not Available |
Fault code: C611 - Not in FSC dictionary,diagnostic code only |
NO_CASE |
|
|
11-Aug-14 |
|
72697 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.DC11_VSM45 |
SDP |
Not Available |
Fault code: DC11 - Not in FSC dictionary,diagnostic code only |
NO_CASE |
|
|
11-Aug-14 |
|
72859 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP.BB05_VSM45 |
SDP |
Not Available |
Fault code: BB05 - ISF returned status indicating the Control Store RAM test failed. Unfence of the ISF was failed. |
NO_CASE |
|
|
28-Apr-14 |
|
49222 |
VSM4,VSM5 |
79A5 Add to SR |
79A5 Add to SR |
|
For each FSC79A5 event, first check if open SR for same serial and for 79A5-> If open SR found, append event info to open SR and exit-> If no open SR, check for any previous 79A5 events within past 7 days--> If no previous events in past 7 days, ignore event (do not create SR), and exit--> If one or more previous events in past 7 days, open SR and transfer to TSC, and exit |
DATA_PROCESSING |
|
|
|
|
49223 |
VSM4,VSM5 |
79A5 srclosed |
79A5 srclosed |
|
For each FSC79A5 event, first check if open SR for same serial and for 79A5-> If open SR found, append event info to open SR and exit-> If no open SR, check for any previous 79A5 events within past 7 days--> If no previous events in past 7 days, ignore event (do not create SR), and exit--> If one or more previous events in past 7 days, open SR and transfer to TSC, and exit |
DATA_PROCESSING |
|
|
|
|
Rule ID |
Product |
Rule Name |
Source |
Knowledge Link |
Description |
Action |
Severity |
History |
Last Update Date |
Reason |
---|---|---|---|---|---|---|---|---|---|---|
72272 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.2A02_VSM45 |
SDP2 |
Not Available |
Fault code: 2A02 - Diagnostics failure during IML |
CASE |
2 |
|
28-Apr-14 |
|
72275 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.2113_VSM45 |
SDP2 |
Not Available |
Fault code: 2113 - Incorrect file count in DIR FD. |
CASE |
3 |
|
|
|
72278 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3300_VSM45 |
SDP2 |
Not Available |
Fault code: 3300 - The adt timer popped on a write cmd before the adt transfer finished. |
CASE |
3 |
|
|
|
72281 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3330_VSM45 |
SDP2 |
Not Available |
Fault code: 3330 - The adt timer popped on a write cmd before the adt transfer finished. |
CASE |
3 |
|
|
|
72284 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3500_VSM45 |
SDP2 |
Not Available |
Fault code: 3500 - The DC function has timed out during a read operation and the hardware has been reset. |
CASE |
2 |
|
11-Aug-14 |
|
72290 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3545_VSM45 |
SDP2 |
Not Available |
Fault code: 3545 - A compressor-detected channel parity error has occurred on the DC hardware during a write operation. |
CASE |
2 |
|
|
|
72293 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3546_VSM45 |
SDP2 |
Not Available |
Fault code: 3546 - FSC3546_DC_WT_VIRT_CRC_ERR_ON_IEA2 |
CASE |
2 |
|
|
|
72296 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3657_VSM45 |
SDP2 |
Not Available |
Fault code: 3657 - A failure event was detected when either the cache data or the cache tag data had bad parity. |
CASE |
2 |
|
|
|
72299 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3659_VSM45 |
SDP2 |
Not Available |
Fault code: 3659 - A Control Bus Check 1 report generated by the Control Bus hardware performing the Check 1 recovery. |
CASE |
2 |
|
|
|
72302 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3663_VSM45 |
SDP2 |
Not Available |
Fault code: 3663 - A DRAM leaf failure event was filed by the memory leaf logic and was recovered by ECC logic. |
CASE |
3 |
|
|
|
72305 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3802_VSM45 |
SDP2 |
Not Available |
Fault code: 3802 - An IUP received a micro-second counter error interrupt |
CASE |
3 |
|
|
|
72311 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7342_VSM45 |
SDP2 |
Not Available |
Fault code: 7342 - New spare count indicates 2 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72314 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7343_VSM45 |
SDP2 |
Not Available |
Fault code: 7343 - New spare count indicates 3 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72317 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7344_VSM45 |
SDP2 |
Not Available |
Fault code: 7344 - New spare count indicates 4 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72320 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7345_VSM45 |
SDP2 |
Not Available |
Fault code: 7345 - New spare count indicates 5 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72323 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7346_VSM45 |
SDP2 |
Not Available |
Fault code: 7346 - New spare count indicates 6 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72326 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7347_VSM45 |
SDP2 |
Not Available |
Fault code: 7347 - New spare count indicates 7 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72329 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7348_VSM45 |
SDP2 |
Not Available |
Fault code: 7348 - New spare count indicates 8 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72332 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7349_VSM45 |
SDP2 |
Not Available |
Fault code: 7349 - New spare count indicates 9 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72335 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.734A_VSM45 |
SDP2 |
Not Available |
Fault code: 734A - New spare count indicates 10 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72338 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.734B_VSM45 |
SDP2 |
Not Available |
Fault code: 734B - New spare count indicates 11 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72341 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.734C_VSM45 |
SDP2 |
Not Available |
Fault code: 734C - New spare count indicates 12 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72344 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.734D_VSM45 |
SDP2 |
Not Available |
Fault code: 734D - New spare count indicates 13 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72347 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.734E_VSM45 |
SDP2 |
Not Available |
Fault code: 734E - New spare count indicates 14 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72350 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.734F_VSM45 |
SDP2 |
Not Available |
Fault code: 734F - New spare count indicates 15 broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72353 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7350_VSM45 |
SDP2 |
Not Available |
Fault code: 7350 - New spare count indicates 16 or more broken drives exist in the subsystem at this time. |
CASE |
2 |
Modified |
28-Apr-14 |
|
72359 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7420_VSM45 |
SDP2 |
Not Available |
Fault code: 7420 - When reading data from a power ASIC the data returned failed parity check. |
CASE |
2 |
|
|
|
72362 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7464_VSM45 |
SDP2 |
Not Available |
Fault code: 7464 - IXB has detected a bad battery during a battery integrity test. |
CASE |
3 |
|
|
|
72365 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7596_VSM45 |
SDP2 |
Not Available |
Fault code: 7596 - FSC 7596 (CAT3) Warm boot, FIP reset |
CASE |
2 |
|
|
|
72368 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.8804_VSM45 |
SDP2 |
Not Available |
Fault code: 8804 - The Qlogic ISP2310 reported a system error. |
CASE |
3 |
|
|
|
72371 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.8940_VSM45 |
SDP2 |
Not Available |
Fault code: 8940 - The FIP processor reported a fatal error condition by asserting a Critical Interrupt. |
CASE |
3 |
|
|
|
72374 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.305A_VSM45 |
SDP2 |
Not Available |
Fault code: 305A - The hardware detects a virtual field CRC error on data received during an ADT read data transfer. |
CASE |
2 |
|
|
|
72377 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.32C0_VSM45 |
SDP2 |
Not Available |
Fault code: 32C0 - An ICE CIP memory parity check 2 error was detected. |
CASE |
3 |
|
|
|
72380 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.32CB_VSM45 |
SDP2 |
Not Available |
Fault code: 32CB - CIP detected check2 error occurred with recovery code of no recovery. |
CASE |
3 |
|
|
|
72383 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.32CF_VSM45 |
SDP2 |
Not Available |
Fault code: 32CF - A CIP detected check2 error occurred and the recovery is to recognize a unit check. |
CASE |
3 |
|
|
|
72386 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.32E0_VSM45 |
SDP2 |
Not Available |
Fault code: 32E0 - A CIP detected check2 error occurred and the recovery is to recognize a unit check for a PPRC secondary channel only. |
CASE |
3 |
|
|
|
72389 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.32E4_VSM45 |
SDP2 |
Not Available |
Fault code: 32E4 - An VCF4 VIFA4 FPGA Configuration SRAM CRC check 2 error was detected. |
CASE |
3 |
|
|
|
72392 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.389E_VSM45 |
SDP2 |
Not Available |
Fault code: 389E - Check 1 recovery hardware was unable to recover from a control bus write failure after retries. |
CASE |
2 |
|
|
|
72395 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.38BE_VSM45 |
SDP2 |
Not Available |
Fault code: 38BE - Check 1 recovery hardware was unable to recover from a control bus read failure after retries. |
CASE |
2 |
|
|
|
72398 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.38C3_VSM45 |
SDP2 |
Not Available |
Fault code: 38C3 - The address for an access to data memory was not within data memory boundaries. |
CASE |
2 |
|
|
|
72401 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.38DB_VSM45 |
SDP2 |
Not Available |
Fault code: 38DB - A data parity error was detected by the PowerPC processor on an access to the L2 cache. |
CASE |
3 |
|
|
|
72404 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3931_VSM45 |
SDP2 |
Not Available |
Fault code: 3931 - Hot channel interrupt |
CASE |
2 |
|
|
|
72407 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E00_VSM45 |
SDP2 |
Not Available |
Fault code: 3E00 - Drive Declared Broken |
CASE |
3 |
|
|
|
72416 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E40_VSM45 |
SDP2 |
Not Available |
Fault code: 3E40 - Conditional Capacity FSC: Production Partition in Subsystem is out of Conditional Capacity. |
CASE |
2 |
|
|
|
72425 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E5F_VSM45 |
SDP2 |
Not Available |
Fault code: 3E5F - Spares needed |
CASE |
1 |
|
|
|
72428 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E60_VSM45 |
SDP2 |
Not Available |
Fault code: 3E60 - Spares Alert FSC: No Useable Spares in Subsystem. |
CASE |
2 |
|
|
|
72476 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E73_VSM45 |
SDP2 |
Not Available |
Fault code: 3E73 - The Emperor Destage Task could not write data to a drive in a Redundancy Group. |
CASE |
3 |
|
|
|
72479 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.72A6_VSM45 |
SDP2 |
Not Available |
Fault code: 72A6 - A corrupted version of the config.cfg file was found. |
CASE |
2 |
|
|
|
72482 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.73D8_VSM45 |
SDP2 |
Not Available |
Fault code: 73D8 - Drive RTD in maint mode |
CASE |
3 |
|
|
|
72488 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.741F_VSM45 |
SDP2 |
Not Available |
Fault code: 741F - During serial communications to an IFES after a preset number of bits are clocked out onto the bus an interrupt is triggered FEP timed out while waiting for this interrupt. |
CASE |
2 |
|
|
|
72491 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.748F_VSM45 |
SDP2 |
Not Available |
Fault code: 748F - MON has detected a bad blower in the penguin. |
CASE |
3 |
|
|
|
72494 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.74AF_VSM45 |
SDP2 |
Not Available |
Fault code: 74AF - Three of the four Penguin fans are indicating that they are failing. |
CASE |
2 |
|
|
|
72497 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.765F_VSM45 |
SDP2 |
Not Available |
Fault code: 765F - Third level recovery has started. Customer data will not be accessible until recovery completes. |
CASE |
2 |
|
|
|
72500 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.776B_VSM45 |
SDP2 |
Not Available |
Fault code: 776B - The ISP Maintenance Bus task has detected an IUP which has entered a Double Check 0 state. |
CASE |
2 |
|
|
|
72503 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.776C_VSM45 |
SDP2 |
Not Available |
Fault code: 776C - The ISP Maintenance Bus task has detected an IUP which has entered a halted state. |
CASE |
2 |
|
|
|
72509 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.79EE_VSM45 |
SDP2 |
Not Available |
Fault code: 79EE - Failed FRU (Fenced) |
CASE |
3 |
|
|
|
72512 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.79F0_VSM45 |
SDP2 |
Not Available |
Fault code: 79F0 - Power offline/lost – Region 0 |
CASE |
3 |
|
|
|
72515 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.79F1_VSM45 |
SDP2 |
Not Available |
Fault code: 79F1 - Power offline/lost – Region 1 |
CASE |
3 |
|
|
|
72524 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7A50_VSM45 |
SDP2 |
Not Available |
Fault code: 7A50 - FSC 7A50 (CAT1): Device Degraded |
CASE |
3 |
|
|
|
72527 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7B22_VSM45 |
SDP2 |
Not Available |
Fault code: 7B22 - This is an FSC reserved for automated testing of the PSA task. |
CASE |
2 |
|
|
|
72530 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7B4E_VSM45 |
SDP2 |
Not Available |
Fault code: 7B4E - ISP SCSI hard drive 0 has been fenced. |
CASE |
2 |
|
|
|
72533 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7B4F_VSM45 |
SDP2 |
Not Available |
Fault code: 7B4F - ISP SCSI hard drive 1 has been fenced. |
CASE |
2 |
|
|
|
72536 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7C24_VSM45 |
SDP2 |
Not Available |
Fault code: 7C24 - This power supply is not producing any output. |
CASE |
2 |
|
|
|
72539 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7C54_VSM45 |
SDP2 |
Not Available |
Fault code: 7C54 - Used only in failure reports reporting a proc copy switch completed on the new-master and the reason for the switch |
CASE |
3 |
|
|
|
72542 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7C59_VSM45 |
SDP2 |
Not Available |
Fault code: 7C59 - The slave ISP is not operational and should be replaced. |
CASE |
2 |
|
|
|
72545 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7E92_VSM45 |
SDP2 |
Not Available |
Fault code: 7E92 - The environmental monitoring task has determined that the N_INT power supply failure line from the logic card cage power supply in power zone 0 is no longer supplying power to the system. |
CASE |
2 |
|
|
|
72548 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7E93_VSM45 |
SDP2 |
Not Available |
Fault code: 7E93 - The environmental monitoring task has determined that the N_INT power supply failure line from the logic card cage power supply in power zone 1 is no longer supplying power to the system. |
CASE |
2 |
|
|
|
72551 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7E99_VSM45 |
SDP2 |
Not Available |
Fault code: 7E99 - PDU shows power supplied to logic card cage power supply fans has tripped a current limiting device. |
CASE |
2 |
|
11-Aug-14 |
|
72554 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7EB1_VSM45 |
SDP2 |
Not Available |
Fault code: 7EB1 - The environmental monitoring system indicates that the PDU AC sensor shows that AC is missing in power zone 1 but that the logic card cage power supply in the zone 1 is still showing AC as being present. |
CASE |
2 |
|
|
|
72557 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7EBB_VSM45 |
SDP2 |
Not Available |
Fault code: 7EBB - One ISP card senses a bad blower and the other does not. Suspect FRUs - ISP card, blower cable, motherboard. |
CASE |
3 |
|
|
|
72560 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.881D_VSM45 |
SDP2 |
Not Available |
Fault code: 881D - The expression for an 'Assert' has evaluated to FALSE. |
CASE |
3 |
|
|
|
72563 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.882B_VSM45 |
SDP2 |
Not Available |
Fault code: 882B - This indicates the VFCC detected an error during a Link Buffer transaction. |
CASE |
3 |
|
|
|
72566 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.883B_VSM45 |
SDP2 |
Not Available |
Fault code: 883B - The Qlogic ISP2300 responds to a send iu that indicated a FC_TIMEOUT condition. |
CASE |
3 |
|
|
|
72572 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.898B_VSM45 |
SDP2 |
Not Available |
Fault code: 898B - A recoverable PPC Machine Check Exception has occurred. |
CASE |
3 |
|
|
|
72575 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.8B01_VSM45 |
SDP2 |
Not Available |
Fault code: 8B01 - An error was detected by a FIP and signaled to the IUP via the Check-2 facility. |
CASE |
3 |
|
|
|
72578 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.8E3D_VSM45 |
SDP2 |
Not Available |
Fault code: 8E3D - A FIP coldstart occurred and the IUP is taking the one time SNO to capture the FIP statesave. |
CASE |
2 |
|
|
|
72581 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.8E4A_VSM45 |
SDP2 |
Not Available |
Fault code: 8E4A - VTDFM has encountered an unrecoverable error in a VTV |
CASE |
2 |
|
|
|
72584 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.8E4B_VSM45 |
SDP2 |
Not Available |
Fault code: 8E4B - VTDFM has encountered an unrecoverable error in a VTV. |
CASE |
2 |
|
|
|
72587 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.8FEE_VSM45 |
SDP2 |
Not Available |
Fault code: 8FEE - Nearlink ERA handling detected a condition requiring the RTD to be forced offline. |
CASE |
3 |
|
|
|
72590 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.9203_VSM45 |
SDP2 |
Not Available |
Fault code: 9203 - Data assurance check |
CASE |
1 |
|
|
|
72596 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.B612_VSM45 |
SDP2 |
Not Available |
Fault code: B612 - The CTR function was driving the ADT bus when an error occurred or the CTR function was in use as a slave when it encountered an error that the ADT function on the IFF didn't. |
CASE |
2 |
|
|
|
72599 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.B705_VSM45 |
SDP2 |
Not Available |
Fault code: B705 - ESSI received a status packet from the ISF that had an invalid serial number. |
CASE |
3 |
|
|
|
72602 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.B827_VSM45 |
SDP2 |
Not Available |
Fault code: B827 - The IFF has sent an Alert Loop Down unsolicited status indicating that the FC Loop is down. |
CASE |
2 |
|
|
|
72605 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.B828_VSM45 |
SDP2 |
Not Available |
Fault code: B828 - The IFF has sent an Alert Loop Boot unsolicited status indicating that the FC Loop transitioned to a boot state. |
CASE |
2 |
|
|
|
72608 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.B834_VSM45 |
SDP2 |
Not Available |
Fault code: B834 - The IFF has sent an Alert Loop Heartbeat unsolicited status indicating that an IFES has stopped responding to heartbeats sent by the IFF. |
CASE |
2 |
|
|
|
72611 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.B90C_VSM45 |
SDP2 |
Not Available |
Fault code: B90C - Failed Drive |
CASE |
3 |
|
|
|
72614 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.B90D_VSM45 |
SDP2 |
Not Available |
Fault code: B90D - Failed Drive |
CASE |
3 |
|
|
|
72617 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BA03_VSM45 |
SDP2 |
Not Available |
Fault code: BA03 - An IFF card has been asynchronously isolated from the FC loop. |
CASE |
3 |
|
|
|
72620 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BA04_VSM45 |
SDP2 |
Not Available |
Fault code: BA04 - Request to fence an FCBE drive because it is present on one FC Loop but bypassed from the other. |
CASE |
3 |
|
|
|
72623 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BA05_VSM45 |
SDP2 |
Not Available |
Fault code: BA05 - Failed Drive |
CASE |
3 |
|
|
|
72626 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BA06_VSM45 |
SDP2 |
Not Available |
Fault code: BA06 - Failed Drive |
CASE |
3 |
|
|
|
72629 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BA07_VSM45 |
SDP2 |
Not Available |
Fault code: BA07 - IFES card failed |
CASE |
2 |
|
|
|
72632 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BA08_VSM45 |
SDP2 |
Not Available |
Fault code: BA08 - IFES card failed |
CASE |
2 |
|
|
|
72635 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BA11_VSM45 |
SDP2 |
Not Available |
Fault code: BA11 - An IFF has not sent the IUP a Command Buffer Available interrupt within the specified time. |
CASE |
2 |
|
|
|
72638 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BA12_VSM45 |
SDP2 |
Not Available |
Fault code: BA12 - An ISF has not returned an abort tag status packet to the IUP within the specified time period. |
CASE |
3 |
|
|
|
72641 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BA13_VSM45 |
SDP2 |
Not Available |
Fault code: BA13 - An IFF NMI has occurred that was forced by the IFF's internal hardware error detection circuitry. |
CASE |
3 |
|
|
|
72644 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BA15_VSM45 |
SDP2 |
Not Available |
Fault code: BA15 - ESI code received unsolicited status packet from IFF indicating IFF took an NMI. |
CASE |
2 |
|
05-Nov-14 |
|
72647 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BB09_VSM45 |
SDP2 |
Not Available |
Fault code: BB09 - ESI timed out waiting for the ISF boot diagnostics to return status. |
CASE |
3 |
|
|
|
72650 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BB0A_VSM45 |
SDP2 |
Not Available |
Fault code: BB0A - ESI received bad or corrupt status from the ISF boot diagnostics. |
CASE |
3 |
|
|
|
72653 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BB0C_VSM45 |
SDP2 |
Not Available |
Fault code: BB0C - The ISF returned status indicating the boot diagnostic tests failed. |
CASE |
3 |
|
|
|
72659 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.C313_VSM45 |
SDP2 |
Not Available |
Fault code: C313 - Device Degraded |
CASE |
2 |
|
|
|
72668 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.D00C_VSM45 |
SDP2 |
Not Available |
Fault code: D00C - Failed Drive |
CASE |
3 |
|
|
|
72671 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.D00E_VSM45 |
SDP2 |
Not Available |
Fault code: D00E - A FCAL link level IOCB command failed because the target sent or requested less data than expected. |
CASE |
3 |
|
|
|
72674 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.D01B_VSM45 |
SDP2 |
Not Available |
Fault code: D01B - Failed Drive |
CASE |
3 |
|
|
|
72677 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.D01D_VSM45 |
SDP2 |
Not Available |
Fault code: D01D - Failed Drive |
CASE |
3 |
|
|
|
72680 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.D039_VSM45 |
SDP2 |
Not Available |
Fault code: D039 - Failed Drive |
CASE |
3 |
|
|
|
72683 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.D057_VSM45 |
SDP2 |
Not Available |
Fault code: D057 - Failed Drive |
CASE |
3 |
|
|
|
72686 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.D075_VSM45 |
SDP2 |
Not Available |
Fault code: D075 - Failed Drive |
CASE |
3 |
|
|
|
72689 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.D078_VSM45 |
SDP2 |
Not Available |
Fault code: D078 - Failed Drive |
CASE |
3 |
|
|
|
72692 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.D082_VSM45 |
SDP2 |
Not Available |
Fault code: D082 - Failed Drive |
CASE |
3 |
|
|
|
72695 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.DC10_VSM45 |
SDP2 |
Not Available |
Fault code: DC10 - The IFF hardware reported a fatal error condition by asserting a Critical Interrupt. |
CASE |
3 |
|
|
|
72701 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F301_VSM45 |
SDP2 |
Not Available |
Fault code: F301 - The caller of cc_generate_fsc passed in a parameter which indicates that the calling function timed out waiting for a response from cache hardware. |
CASE |
2 |
|
|
|
72704 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F30A_VSM45 |
SDP2 |
Not Available |
Fault code: F30A - Analysis of cache status in cc_generate_fsc indicates an ADT Overrun involving backend port occurred |
CASE |
2 |
|
|
|
72707 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F31B_VSM45 |
SDP2 |
Not Available |
Fault code: F31B - cc_generate_fsc indicates that an ADT Overrun involving a |
CASE |
3 |
|
|
|
72710 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F31C_VSM45 |
SDP2 |
Not Available |
Fault code: F31C - backend port occurred. |
CASE |
2 |
|
|
|
72713 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F31E_VSM45 |
SDP2 |
Not Available |
Fault code: F31E - The analysis of cache status and state done in cc_generate_fsc indicates that a link level timeout was detected in the ACPORT MAC. Possible failing FRUs: ACMI, ANV, AVM |
CASE |
2 |
|
|
|
72716 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F400_VSM45 |
SDP2 |
Not Available |
Fault code: F400 - Connection Request Word received by ACPORT MAC receive layer did not have BREAK bit set, which indicates that the packet was truncated. |
CASE |
2 |
|
|
|
72719 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F401_VSM45 |
SDP2 |
Not Available |
Fault code: F401 - ACPORT MAC receive layer has detected a protocol error during reception of a packet. Possible failing FRUs: ACMI, AVM, ANV |
CASE |
2 |
|
|
|
72722 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F403_VSM45 |
SDP2 |
Not Available |
Fault code: F403 - ACPORT MAC received a packet out of sequence. Possible failing FRUs: ACMI, AVM, ANV |
CASE |
2 |
|
|
|
72725 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F406_VSM45 |
SDP2 |
Not Available |
Fault code: F406 - AMPORT MAC receive layer has detected an invalid CRC for a received packet on a Primary access. |
CASE |
2 |
|
|
|
72728 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F407_VSM45 |
SDP2 |
Not Available |
Fault code: F407 - AMPORT MAC receive layer has detected an invalid CRC for a received packet on an Alternate access. |
CASE |
2 |
|
|
|
72731 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F40A_VSM45 |
SDP2 |
Not Available |
Fault code: F40A - SDRAM controller associated with the primary cache access detected an uncorrectable EDAC error on a read. |
CASE |
2 |
|
|
|
72734 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F40B_VSM45 |
SDP2 |
Not Available |
Fault code: F40B - SDRAM controller associated with the alternate cache access detected an uncorrectable EDAC error on a read. |
CASE |
2 |
|
|
|
72737 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F411_VSM45 |
SDP2 |
Not Available |
Fault code: F411 - SDRAM controller associated with the primary cache access detected an LPW error. |
CASE |
2 |
|
|
|
72740 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F4C2_VSM45 |
SDP2 |
Not Available |
Fault code: F4C2 - Device Degraded |
CASE |
3 |
|
|
|
72743 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F500_VSM45 |
SDP2 |
Not Available |
Fault code: F500 - The caller of cc_generate_pfa passed in a parameter which indicates that the calling function detected a User Handled Check 1 while accessing the ADT count register. |
CASE |
2 |
|
|
|
72746 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F502_VSM45 |
SDP2 |
Not Available |
Fault code: F502 - The caller of cc_generate_pfa passed in a parameter which indicates that the calling function detected a User Handled Check 1 while accessing the UPDR register. |
CASE |
2 |
|
|
|
72749 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F520_VSM45 |
SDP2 |
Not Available |
Fault code: F520 - The analysis of cache status and state done in cc_generate_fsc indicates that a 1 bit error was detected during a read operation and it was corrected. |
CASE |
3 |
|
|
|
72752 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.32CC_VSM45 |
SDP2 |
Not Available |
Fault code: 32CC - Either status frame or command response frame was sent, but the accept command is still pending. |
CASE |
3 |
|
04-Apr-14 |
|
72755 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.33C7_VSM45 |
SDP2 |
Not Available |
Fault code: 33C7 - An ICE port selection check 2 error was detected during a write adt. |
CASE |
3 |
|
04-Apr-14 |
|
72758 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3653_VSM45 |
SDP2 |
Not Available |
Fault code: 3653 - A failure event was detected in one of the eight ports that receive shared memory write packets. |
CASE |
3 |
|
04-Apr-14 |
|
72761 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.38B0_VSM45 |
SDP2 |
Not Available |
Fault code: 38B0 - chk0 occurred, shared memory access was attempted when interface was fenced due to content error. |
CASE |
3 |
|
04-Apr-14 |
|
72764 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.71C7_VSM45 |
SDP2 |
Not Available |
Fault code: 71C7 - packet stream or an operational port detected an incorrect sequence of headers and content words. |
CASE |
3 |
|
04-Apr-14 |
|
72767 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.74D9_VSM45 |
SDP2 |
Not Available |
Fault code: 74D9 - FIML detected that the IUP boot code halted and there is no status data in the FIFO. |
CASE |
3 |
|
04-Apr-14 |
|
72770 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.74DD_VSM45 |
SDP2 |
Not Available |
Fault code: 74DD - FIML has received an failure message from the IUP boot code. The FIFO will contain error status. |
CASE |
3 |
|
04-Apr-14 |
|
72773 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7503_VSM45 |
SDP2 |
Not Available |
Fault code: 7503 - FIML did not receive a response to the establish communications message. |
CASE |
3 |
|
04-Apr-14 |
|
72776 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.75B3_VSM45 |
SDP2 |
Not Available |
Fault code: 75B3 - A device interface card failed an unfence due to a hardware error returned by VFN to FEN. |
CASE |
3 |
|
04-Apr-14 |
|
72779 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7600_VSM45 |
SDP2 |
Not Available |
Fault code: 7600 - An ISP has detected a Check 0 occurred during a Warm Boot. |
CASE |
3 |
|
04-Apr-14 |
|
72782 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7C5A_VSM45 |
SDP2 |
Not Available |
Fault code: 7C5A - The alternate ISP has taken a fatal error. |
CASE |
3 |
|
04-Apr-14 |
|
72785 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7E98_VSM45 |
SDP2 |
Not Available |
Fault code: 7E98 - Power to logic card cage power supply fans has tripped a current limiting device within the PDU. |
CASE |
3 |
|
04-Apr-14 |
|
72788 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7EA7_VSM45 |
SDP2 |
Not Available |
Fault code: 7EA7 - The PDU on side 1 shows that thermal switch 1, on the IHP card, is closed. |
CASE |
3 |
|
04-Apr-14 |
|
72791 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.8844_VSM45 |
SDP2 |
Not Available |
Fault code: 8844 - An SB-2 CRC error was detected during an ADT write operation. |
CASE |
3 |
|
04-Apr-14 |
|
72794 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BA0B_VSM45 |
SDP2 |
Not Available |
Fault code: BA0B - IFF card failed ESI controlled restart after having NMI or similar prob. Most likely IFF HW prob. |
CASE |
3 |
|
04-Apr-14 |
|
72797 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.D034_VSM45 |
SDP2 |
Not Available |
Fault code: D034 - This indicates that at the end of a data sector the CRC remainders are not zero (CRC Check 0). |
CASE |
3 |
|
04-Apr-14 |
|
72800 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F305_VSM45 |
SDP2 |
Not Available |
Fault code: F305 - Analysis of cache status and state indicates major ACMI Card problems (ACMI Internal Error). |
CASE |
3 |
|
04-Apr-14 |
|
72803 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F306_VSM45 |
SDP2 |
Not Available |
Fault code: F306 - Analysis of cache status and state indicates ADT Parity Error involving the frontend port occurred. |
CASE |
3 |
|
04-Apr-14 |
|
72806 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F307_VSM45 |
SDP2 |
Not Available |
Fault code: F307 - Analysis of cache status and state indicates ADT Parity Error involving the backend port occurred. |
CASE |
3 |
|
04-Apr-14 |
|
72809 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.38BB_VSM45 |
SDP2 |
Not Available |
Fault code: 38BB - Bus transaction stalled for a period between one and two of the intervals programmed. |
CASE |
3 |
|
04-Apr-14 |
|
72812 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.8635_VSM45 |
SDP2 |
Not Available |
Fault code: 8635 - Check 1: Attempt to access a region of the address space at which no memory or registers reside. |
CASE |
3 |
|
04-Apr-14 |
|
72815 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.8AFF_VSM45 |
SDP2 |
Not Available |
Fault code: 8AFF - FSC8XXX_FIP_HIGH |
CASE |
3 |
|
04-Apr-14 |
|
72818 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F31D_VSM45 |
SDP2 |
Not Available |
Fault code: F31D - Cache status in cc_generate_fsc indicates invalid node number via the \"Alternate\" memory card path. |
CASE |
3 |
|
04-Apr-14 |
|
72821 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.9571_VSM45 |
SDP2 |
Not Available |
Fault code: 9571 - none |
CASE |
3 |
|
04-Apr-14 |
|
72824 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.32C1_VSM45 |
SDP2 |
Not Available |
Fault code: 32C1 - ICE ECB address parity check 2 error was detected. |
CASE |
3 |
|
04-Apr-14 |
|
72827 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.38EA_VSM45 |
SDP2 |
Not Available |
Fault code: 38EA - FSC38EA_PROC_DETECTED_L1_DATA_CACHE_ERROR |
CASE |
3 |
|
04-Apr-14 |
|
72830 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.DC33_VSM45 |
SDP2 |
Not Available |
Fault code: DC33 - none |
CASE |
3 |
|
04-Apr-14 |
|
72833 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F30C_VSM45 |
SDP2 |
Not Available |
Fault code: F30C - Cache status in cc_generate_fsc indicates that ADT Underrun involving a backend port occurred. |
CASE |
3 |
|
04-Apr-14 |
|
72836 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F402_VSM45 |
SDP2 |
Not Available |
Fault code: F402 - ACPORT MAC receive layer has detected an invalid CRC for a received packet. |
CASE |
3 |
|
04-Apr-14 |
|
72839 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F410_VSM45 |
SDP2 |
Not Available |
Fault code: F410 - SDRAM controller associated with the primary cache access detected an LPW error. |
CASE |
3 |
|
04-Apr-14 |
|
72842 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F480_VSM6 |
SDP2 |
Not Available |
Fault code: F480 - none |
CASE |
3 |
|
04-Apr-14 |
|
72845 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F489_VSM45 |
SDP2 |
Not Available |
Fault code: F489 - none |
CASE |
3 |
|
04-Apr-14 |
|
72848 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.F582_VSM45 |
SDP2 |
Not Available |
Fault code: F582 - none |
CASE |
3 |
|
04-Apr-14 |
|
72851 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.9900_VSM45 |
SDP2 |
Not Available |
Fault code: 9900 - IUP initiated offload request to send a MEM to offload this debug data in the corresponding \"T\" file |
CASE |
3 |
|
04-Apr-14 |
|
72854 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.210D_VSM45 |
SDP2 |
Not Available |
Fault code: 210D - Indicates a file descriptor (FD) is marked in use, is NOT being used by any file in any directory. |
CASE |
3 |
|
28-Apr-14 |
|
72857 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.776A_VSM45 |
SDP2 |
Not Available |
Fault code: 776A - All Maintenance Bus paths from a particular ISP have fenced. GFR of ISP is needed. |
CASE |
2 |
|
28-Apr-14 |
|
72506 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.79A5_VSM45 |
SDP2 |
Not Available |
Fault code: 79A5 - Log overflow |
COMPLEX |
3 |
Modified |
27-May-14 |
|
76202 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.73F8_VSM45 |
SDP2 |
Not Available |
Fault code: 73F8 - The ISP has detected that the amount of ISP disk space available has reached a minimum threshold of either less that 30Mb or less than 200 file handles left. |
COMPLEX |
3 |
Modified |
10-Aug-15 |
|
72287 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3509_VSM45 |
SDP2 |
Not Available |
Fault code: 3509 - A virtual field CRC error has occurred on the decompressor CRC checker during a read operation. |
NO_CASE |
|
|
11-Aug-14 |
|
72308 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7341_VSM45 |
SDP2 |
Not Available |
Fault code: 7341 - New spare count indicates 1 broken drives exist in the subsystem at this time. |
NO_CASE |
|
|
|
|
72356 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7358_VSM45 |
SDP2 |
Not Available |
Fault code: 7358 - 90 day code notice |
NO_CASE |
|
|
|
|
72410 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E01_VSM45 |
SDP2 |
Not Available |
Fault code: 3E01 - Broken Drive is being Reconstructed (started). |
NO_CASE |
|
|
|
|
72413 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E02_VSM45 |
SDP2 |
Not Available |
Fault code: 3E02 - Broken Drive has completed Reconstruction. |
NO_CASE |
|
|
|
|
72419 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E41_VSM45 |
SDP2 |
Not Available |
Fault code: 3E41 - Conditional Capacity FSC: Production Partition Conditional Capacity Low Threshold Reached. |
NO_CASE |
|
|
|
|
72422 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E42_VSM45 |
SDP2 |
Not Available |
Fault code: 3E42 - Conditional Capacity FSC: Production Partition Conditional Capacity Low Threshold Reached. |
NO_CASE |
|
|
|
|
72431 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E61_VSM45 |
SDP2 |
Not Available |
Fault code: 3E61 - Spares Alert FSC: 1 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72434 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E62_VSM45 |
SDP2 |
Not Available |
Fault code: 3E62 - Spares Alert FSC: 2 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72437 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E63_VSM45 |
SDP2 |
Not Available |
Fault code: 3E63 - Spares Alert FSC: 3 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72440 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E64_VSM45 |
SDP2 |
Not Available |
Fault code: 3E64 - Spares Alert FSC: 4 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72443 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E65_VSM45 |
SDP2 |
Not Available |
Fault code: 3E65 - Spares Alert FSC: 5 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72446 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E66_VSM45 |
SDP2 |
Not Available |
Fault code: 3E66 - Spares Alert FSC: 6 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72449 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E67_VSM45 |
SDP2 |
Not Available |
Fault code: 3E67 - Spares Alert FSC: 7 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72452 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E68_VSM45 |
SDP2 |
Not Available |
Fault code: 3E68 - Spares Alert FSC: 8 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72455 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E69_VSM45 |
SDP2 |
Not Available |
Fault code: 3E69 - Spares Alert FSC: 9 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72458 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E6A_VSM45 |
SDP2 |
Not Available |
Fault code: 3E6A - Spares Alert FSC: 10 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72461 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E6B_VSM45 |
SDP2 |
Not Available |
Fault code: 3E6B - Spares Alert FSC: 11 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72464 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E6C_VSM45 |
SDP2 |
Not Available |
Fault code: 3E6C - Spares Alert FSC: 12 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72467 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E6D_VSM45 |
SDP2 |
Not Available |
Fault code: 3E6D - Spares Alert FSC: 13 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72470 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E6E_VSM45 |
SDP2 |
Not Available |
Fault code: 3E6E - Spares Alert FSC: 14 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72473 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.3E6F_VSM45 |
SDP2 |
Not Available |
Fault code: 3E6F - Spares Alert FSC: 15 Usable Spare in Subsystem. |
NO_CASE |
|
|
|
|
72518 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7A00_VSM45 |
SDP2 |
Not Available |
Fault code: 7A00 - Power back online – Region 0 |
NO_CASE |
|
|
|
|
72521 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.7A01_VSM45 |
SDP2 |
Not Available |
Fault code: 7A01 - Power back online – Region 0 |
NO_CASE |
|
|
|
|
72569 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.88A0_VSM45 |
SDP2 |
Not Available |
Fault code: 88A0 - A Virtual Field CRC error was detected during an ADT read operation |
NO_CASE |
|
|
|
|
72593 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.9501_VSM45 |
SDP2 |
Not Available |
Fault code: 9501 - Host link HW error detected causing link reset & host access terminated. Link recovered & restarted. |
NO_CASE |
|
|
11-Aug-14 |
|
72656 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.C210_VSM45 |
SDP2 |
Not Available |
Fault code: C210 - Not in FSC dictionary |
NO_CASE |
|
|
28-Apr-14 |
|
72662 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.C5A2_VSM45 |
SDP2 |
Not Available |
Fault code: C5A2 - Not in FSC dictionary |
NO_CASE |
|
|
28-Apr-14 |
|
72665 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.C611_VSM45 |
SDP2 |
Not Available |
Fault code: C611 - Not in FSC dictionary,diagnostic code only |
NO_CASE |
|
|
11-Aug-14 |
|
72698 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.DC11_VSM45 |
SDP2 |
Not Available |
Fault code: DC11 - Not in FSC dictionary,diagnostic code only |
NO_CASE |
|
|
11-Aug-14 |
|
72860 |
VSM4,VSM5 |
VSM4_5.VSM4___5_Alarms.SDP2.BB05_VSM45 |
SDP2 |
Not Available |
Fault code: BB05 - ISF returned status indicating the Control Store RAM test failed. Unfence of the ISF was failed. |
NO_CASE |
|
|
28-Apr-14 |
|
49222 |
VSM4,VSM5 |
79A5 Add to SR |
79A5 Add to SR |
|
For each FSC79A5 event, first check if open SR for same serial and for 79A5-> If open SR found, append event info to open SR and exit-> If no open SR, check for any previous 79A5 events within past 7 days--> If no previous events in past 7 days, ignore event (do not create SR), and exit--> If one or more previous events in past 7 days, open SR and transfer to TSC, and exit |
DATA_PROCESSING |
|
|
|
|
49223 |
VSM4,VSM5 |
79A5 srclosed |
79A5 srclosed |
|
For each FSC79A5 event, first check if open SR for same serial and for 79A5-> If open SR found, append event info to open SR and exit-> If no open SR, check for any previous 79A5 events within past 7 days--> If no previous events in past 7 days, ignore event (do not create SR), and exit--> If one or more previous events in past 7 days, open SR and transfer to TSC, and exit |
DATA_PROCESSING |
|
|
|
|
Oracle Auto Service Request Fault Coverage – Storage Products: Virtual Storage Manager (VSM)