Oracle is continuously analyzing and improving the ASR fault rules to enhance the Oracle support experience. This includes adding, modifying and removing rules to focus on actionable events from ASR assets while filtering non-actionable events. ASR is designed to enhance the process of creating and resolving Service Requests and is not a replacement for system monitoring. As such, the ASR fault coverage documents represent specific faults that Oracle can automate, not parts that are monitored. The ASR Manager includes a feature to integrate the ASR Service Request creation event into your existing monitoring system. This is described in the ASR Manager documentation on http://oracle.com/asr ... Documentation.


Oracle Database Appliance (ODA)

Oracle Database Appliance (all models)

Rule ID

Product

Rule Name

Source

Knowledge Link

Description

Action

Severity

History

Last Update Date

Reason

50818

Oracle Database Appliance

Xxx7x.ASM_alarms.ASM.DISKALRT_02001

Oracle Appliance Kit

1384257.1

DISKALRT-02001: System os hard disk failure. [ID 1384257.1]

CASE

2

Modified

28-Apr-14

 

50819

Oracle Database Appliance

Xxx7x.ASM_alarms.ASM.DISKALRT_02002

Oracle Appliance Kit

1384258.1

DISKALRT-02002: System os hard disk predictive failure.[ID 1384258.1]

CASE

2

Modified

28-Apr-14

 

50820

Oracle Database Appliance

Xxx7x.ASM_alarms.ASM.DISKALRT_02003

Oracle Appliance Kit

1384881.1

DISKALRT-02003: System os hard disk poor performance. [ID 1384881.1]

CASE

2

Modified

28-Apr-14

 

50821

Oracle Database Appliance

Xxx7x.ASM_alarms.ASM.DISKALRT_02004

Oracle Appliance Kit

1384286.1

DISKALRT-02004: Data hard disk failure. [ID 1384286.1]

CASE

2

Modified

28-Apr-14

 

50822

Oracle Database Appliance

Xxx7x.ASM_alarms.ASM.DISKALRT_02005

Oracle Appliance Kit

1384883.1

DISKALRT-02005: Data hard disk predictive failure. [ID 1384883.1]

CASE

2

Modified

28-Apr-14

 

50823

Oracle Database Appliance

Xxx7x.ASM_alarms.ASM.DISKALRT_02006

Oracle Appliance Kit

1384905.1

DISKALRT-02006: Data hard disk poor performance.[ID 1384905.1]

CASE

2

Modified

28-Apr-14

 

50824

Oracle Database Appliance

Xxx7x.ASM_alarms.ASM.DISKALRT_02007

Oracle Appliance Kit

1384887.1

DISKALRT-02007: Data ssd disk failure. [ID 1384887.1]

CASE

2

 

 

 

50825

Oracle Database Appliance

Xxx7x.ASM_alarms.ASM.DISKALRT_02008

Oracle Appliance Kit

1384890.1

DISKALRT-02008: Data ssd disk predictive failure. [ID 1384890.1]

CASE

2

 

 

 

50826

Oracle Database Appliance

Xxx7x.ASM_alarms.ASM.DISKALRT_02009

Oracle Appliance Kit

1384891.1

DISKALRT-02009: Data ssd disk poor performance. [ID 1384891.1]

CASE

2

 

 

 


X3-2

Rule ID

Product

Rule Name

Source

Knowledge Link

Description

Action

Severity

History

Last Update Date

Reason

14125

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_33_1_EXA

ILOM

SPX86-8000-33

Probable chassis Fan or Power Supply Fan failure

CASE

3

 

 

 

14130

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_AE_1_EXA

ILOM

SPX86-8000-AE

Cache fault on Processor

CASE

2

 

 

 

14131

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_CJ_1_EXA

ILOM

SPX86-8000-CJ

Data Cache Fault on Processor

CASE

2

 

 

 

14132

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_DC_1_EXA

ILOM

SPX86-8000-DC

Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14133

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_EQ_1_EXA

ILOM

SPX86-8000-EQ

Instruction Cache Fault on Processor

CASE

2

 

 

 

14134

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_F4_1_EXA

ILOM

SPX86-8000-F4

Internal Processor Fault

CASE

2

 

 

 

14135

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_GR_1_EXA

ILOM

SPX86-8000-GR

Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14136

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_H3_1_EXA

ILOM

SPX86-8000-H3

Level 0 Cache Fault on Processor

CASE

2

 

 

 

14137

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_JY_1_EXA

ILOM

SPX86-8000-JY

Level 0 Data Cache Fault on Processor

CASE

2

 

 

 

14138

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_KD_1_EXA

ILOM

SPX86-8000-KD

Level 0 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14139

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_LH_1_EXA

ILOM

SPX86-8000-LH

Level 0 Instruction Cache Fault on Processor

CASE

2

 

 

 

14140

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_MA_1_EXA

ILOM

SPX86-8000-MA

Level 0 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14141

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_NP_1_EXA

ILOM

SPX86-8000-NP

Level 0 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14142

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_P5_1_EXA

ILOM

SPX86-8000-P5

Level 1 Cache Fault on Processor

CASE

2

 

 

 

14143

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_QS_1_EXA

ILOM

SPX86-8000-QS

Level 1 Data Cache Fault on Processor

CASE

2

 

 

 

14144

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_RJ_1_EXA

ILOM

SPX86-8000-RJ

Level 1 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14145

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_SE_1_EXA

ILOM

SPX86-8000-SE

Level 1 Instruction Cache Fault on Processor

CASE

2

 

 

 

14146

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_TX_1_EXA

ILOM

SPX86-8000-TX

Level 1 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14147

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_U2_1_EXA

ILOM

SPX86-8000-U2

Level 1 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14148

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_VR_1_EXA

ILOM

SPX86-8000-VR

Level 2 Cache Fault on Processor

CASE

2

 

 

 

14149

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_W4_1_EXA

ILOM

SPX86-8000-W4

Level 2 Data Cache Fault on Processor

CASE

2

 

 

 

14150

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_XQ_1_EXA

ILOM

SPX86-8000-XQ

Level 2 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14151

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_YC_1_EXA

ILOM

SPX86-8000-YC

Level 2 Instruction Cache Fault on Processor

CASE

2

 

 

 

14152

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_0Q_1_EXA

ILOM

SPX86-8001-0Q

Level 2 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14153

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_1C_1_EXA

ILOM

SPX86-8001-1C

Level 2 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14154

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_2R_1_EXA

ILOM

SPX86-8001-2R

Memory Controller fault

CASE

2

 

 

 

14155

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_34_1_EXA

ILOM

SPX86-8001-34

Initialization failure of the Intel Quickpath Interconnect Physical Layer, Link Layer, or Protocol Layer

CASE

2

 

 

 

14156

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_4X_1_EXA

ILOM

SPX86-8001-4X

Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14166

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_ME_1_EXA

ILOM

SPX86-8001-ME

Reviewed 10/28/2011 – Event does not indicate that a part has failed. Added to SAMS reporting for further tracking. Message ID: SPX86-8001-ME indicates that the ILOM fault manager has received

CASE

2

 

 

 

14168

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_QX_1_EXA

ILOM

SPX86-8001-QX

Memory DIMM Temperature Sensor Failed

CASE

2

 

 

 

14171

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_TS_1_EXA

ILOM

SPX86-8001-TS

Memory DIMM Failure During Training

CASE

2

 

 

 

14176

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_2J_1_EXA

ILOM

SPX86-8002-2J

Power to server not available

CASE

2

 

 

 

14182

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_A3_1_EXA

ILOM

SPX86-8002-A3

Potentiometers not responding.

CASE

2

 

 

 

14197

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_Y5_1_EXA

ILOM

SPX86-8002-Y5

Power Supply Internal Failure

CASE

2

 

 

 

14198

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_3A_1_EXA

ILOM

SPX86-8003-3A

Fan Column Failure

CASE

2

 

 

 

14200

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_73_1_EXA

ILOM

SPX86-8003-73

Lack of AC input power.

CASE

3

 

 

 

14201

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_9Q_1_EXA

ILOM

SPX86-8003-9Q

Component temp exceeded

CASE

2

 

 

 

14202

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_CR_1__EXA

ILOM

SPX86-8003-CR

Home Agent error

CASE

2

 

 

 

14203

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_D2_1_EXA

ILOM

SPX86-8003-D2

Intel QPI Link is Slow

CASE

2

 

 

 

14204

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_EX_1_EXA

ILOM

SPX86-8003-EX

Intel QPI Link Training Failure

CASE

2

 

 

 

14205

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_FE_1__EXA

ILOM

SPX86-8003-FE

Memory Controller Uncorrectable Error

CASE

2

 

 

 

14206

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_GJ_1__EXA

ILOM

SPX86-8003-GJ

Memory Scrubbing UE

CASE

2

 

 

 

14207

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_HA_1__EXA

ILOM

SPX86-8003-HA

Unknown Error from QPI Reference Code

CASE

2

 

 

 

14208

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_K5_1__EXA

ILOM

SPX86-8003-K5

Intel Thermtrip Failure

CASE

2

 

 

 

14209

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_LS_1_EXA

ILOM

SPX86-8003-LS

IIO core fatal fault

CASE

2

 

 

 

14210

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_M3_1__EXA

ILOM

SPX86-8003-M3

IIO IRP Fatal Error

CASE

2

 

 

 

14211

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_NY_1__EXA

ILOM

SPX86-8003-NY

IIO Miscellaneous Fatal Error

CASE

2

 

 

 

14213

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_QH_1__EXA

ILOM

SPX86-8003-QH

IIO PCIE fault in downstream devices

CASE

2

 

 

 

14214

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_RR_1__EXA

ILOM

SPX86-8003-RR

IIO PCIE Fatal Error

CASE

2

 

 

 

14215

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_S4_1__EXA

ILOM

SPX86-8003-S4

IIO PCIE Error in Downstream Leaf Devices

CASE

2

 

 

 

14216

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_TQ_1__EXA

ILOM

SPX86-8003-TQ

IIO PCIE Error in Root Port Device

CASE

2

 

 

 

14217

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_UC_1_EXA

ILOM

SPX86-8003-UC

IIO VT-d Fatal Error

CASE

2

 

 

 

14218

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_0D_1__EXA

ILOM

SPX86-8004-0D

DIMM disabled due to memtest errors

CASE

2

 

 

 

14219

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_1H_1_EXA

ILOM

SPX86-8004-1H

Dimm Failed Memtest

CASE

2

 

 

 

14220

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_6A_1__EXA

ILOM

SPX86-8004-6A

DIMM can't run at speeds required by platform

CASE

2

 

 

 

14221

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_7P_1__EXA

ILOM

SPX86-8004-7P

Throttling not sufficient for this DIMM

CASE

2

 

 

 

14222

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_8X_1__EXA

ILOM

SPX86-8004-8X

Single Symbol error Found in DIMM Training

CASE

2

 

 

 

14223

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_AJ_1__EXA

ILOM

SPX86-8004-AJ

Unknown Error from Intel Memory Reference Code

CASE

2

 

 

 

14224

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_CE_1__EXA

ILOM

SPX86-8004-CE

Fault due to excessive memory correctable errors

CASE

2

 

 

 

14225

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_DQ_1_EXA

ILOM

SPX86-8004-DQ

BIOS Hangs due to Intel ME Failure

CASE

2

 

 

 

14226

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_EC_1_EXA

ILOM

SPX86-8004-EC

Catastrophic Error Events

CASE

2

 

 

 

14227

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_FR_1_EXA

ILOM

SPX86-8004-FR

Persistent Catastrophic Error

CASE

2

 

 

 

14228

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_G4_1_EXA

ILOM

SPX86-8004-G4

Failure of Power Source

CASE

2

 

 

 

14233

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8001_EE_EXA

ILOM

INTEL-8001-EE

Memory Bad Parity

CASE

2

 

 

 

14234

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8001_J5_EXA

ILOM

INTEL-8001-J5

Memory Mirror Broken

CASE

2

 

 

 

14235

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8001_G2_EXA

ILOM

INTEL-8001-G2

Spare memory error

CASE

2

 

 

 

14236

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8001_AQ_EXA

ILOM

INTEL-8001-AQ

Multibit memory module errors

CASE

2

 

 

 

14237

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8001_94_EXA

ILOM

INTEL-8001-94

Memory module correctable errors exceeding acceptable levels

CASE

2

 

 

 

14239

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8002_1Y_EXA

ILOM

INTEL-8002-1Y

A Middle Level Cache ECC Uncorrectable Error

CASE

2

 

 

 

14240

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8002_2D_EXA

ILOM

INTEL-8002-2D

A Last Level Cache ECC Uncorrectable Error

CASE

2

 

 

 

14241

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_1J_EXA

ILOM

INTEL-8000-1J

An internal error has been encountered on this cpu.

CASE

2

 

 

 

14242

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_22_EXA

ILOM

INTEL-8000-22

A level 0 cache on this cpu is faulty.

CASE

2

 

 

 

14243

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_3X_EXA

ILOM

INTEL-8000-3X

A level 1 cache on this cpu is faulty

CASE

2

 

 

 

14244

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_44_EXA

ILOM

INTEL-8000-44

A level 2 cache on this cpu is faulty.

CASE

2

 

 

 

14245

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_5R_EXA

ILOM

INTEL-8000-5R

A cache on this cpu is faulty.

CASE

2

 

 

 

14246

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_6C_EXA

ILOM

INTEL-8000-6C

A level 0 Data TLB on this cpu is faulty.

CASE

2

 

 

 

14247

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_7Q_EXA

ILOM

INTEL-8000-7Q

A level 1 Data TLB on this cpu is faulty.

CASE

2

 

 

 

14248

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_8Y_EXA

ILOM

INTEL-8000-8Y

A level 2 Data TLB on this cpu is faulty.

CASE

2

 

 

 

14249

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_93_EXA

ILOM

INTEL-8000-93

A Data TLB on this cpu is faulty.

CASE

2

 

 

 

14250

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_AH_EXA

ILOM

INTEL-8000-AH

A level 0 Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

14251

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_CD_EXA

ILOM

INTEL-8000-CD

A level 1 Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

14252

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_DP_EXA

ILOM

INTEL-8000-DP

A level 2 Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

14253

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_EA_EXA

ILOM

INTEL-8000-EA

An Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

14254

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_FS_EXA

ILOM

INTEL-8000-FS

A level 0 TLB on this cpu is faulty.

CASE

2

 

 

 

14255

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_G5_EXA

ILOM

INTEL-8000-G5

A level 1 TLB on this cpu is faulty.

CASE

2

 

 

 

14256

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_HX_EXA

ILOM

INTEL-8000-HX

A level 2 TLB on this cpu is faulty.

CASE

2

 

 

 

14257

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_J2_EXA

ILOM

INTEL-8000-J2

A TLB on this cpu is faulty.

CASE

2

 

 

 

14258

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_KJ_EXA

ILOM

INTEL-8000-KJ

A level 0 Data Cache on this cpu is faulty.

CASE

2

 

 

 

14259

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_LE_EXA

ILOM

INTEL-8000-LE

A level 1 Data Cache on this cpu is faulty.

CASE

2

 

 

 

14260

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_MQ_EXA

ILOM

INTEL-8000-MQ

A level 2 Data Cache on this cpu is faulty.

CASE

2

 

 

 

14261

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_NC_EXA

ILOM

INTEL-8000-NC

A Data Cache on this cpu is faulty.

CASE

2

 

 

 

14262

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_PR_EXA

ILOM

INTEL-8000-PR

A level 0 Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

14263

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_Q4_EXA

ILOM

INTEL-8000-Q4

A level 1 Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

14264

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_RD_EXA

ILOM

INTEL-8000-RD

A level 2 Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

14265

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8000_SH_EXA

ILOM

INTEL-8000-SH

An Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

14266

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.DISK_8000_0X_EXA

ILOM

DISK-8000-0X

Predictive Disk Failure Imminent

CASE

2

 

 

 

14267

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.DISK_8000_12_EXA

ILOM

DISK-8000-12

Disk Temperature Exceeded Threshold

CASE

2

 

 

 

14268

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.DISK_8000_2J_EXA

ILOM

DISK-8000-2J

Disk Self-Test Failure

CASE

2

 

 

 

14269

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.DISK_8000_3E_EXA

ILOM

DISK-8000-3E

SCSI fault for device

CASE

2

 

 

 

14270

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.DISK_8000_4Q_EXA

ILOM

DISK-8000-4Q

SCSI fault for media

CASE

2

 

 

 

34519

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_U5_1_EXA

ILOM

SPX86-8001-U5

Memory Uncorrectable ECC Fault

CASE

2

 

06-Feb-14

 

48949

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_33_1

ILOM

SPX86-8000-33

Probable chassis Fan or Power Supply Fan failure

CASE

3

Modified

28-Apr-14

 

48950

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_AE_1

ILOM

SPX86-8000-AE

Cache fault on Processor

CASE

2

Modified

28-Apr-14

 

48951

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_CJ_1

ILOM

SPX86-8000-CJ

Data Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48952

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_DC_1

ILOM

SPX86-8000-DC

Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48953

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_EQ_1

ILOM

SPX86-8000-EQ

Instruction Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48954

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_F4_1

ILOM

SPX86-8000-F4

Internal Processor Fault

CASE

2

Modified

28-Apr-14

 

48955

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_GR_1

ILOM

SPX86-8000-GR

Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48956

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_H3_1

ILOM

SPX86-8000-H3

Level 0 Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48957

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_JY_1

ILOM

SPX86-8000-JY

Level 0 Data Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48958

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_KD_1

ILOM

SPX86-8000-KD

Level 0 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48959

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_LH_1

ILOM

SPX86-8000-LH

Level 0 Instruction Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48960

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_MA_1

ILOM

SPX86-8000-MA

Level 0 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48961

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_NP_1

ILOM

SPX86-8000-NP

Level 0 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48962

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_P5_1

ILOM

SPX86-8000-P5

Level 1 Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48963

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_QS_1

ILOM

SPX86-8000-QS

Level 1 Data Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48964

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_RJ_1

ILOM

SPX86-8000-RJ

Level 1 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48965

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_SE_1

ILOM

SPX86-8000-SE

Level 1 Instruction Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48966

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_TX_1

ILOM

SPX86-8000-TX

Level 1 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48967

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_U2_1

ILOM

SPX86-8000-U2

Level 1 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48968

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_VR_1

ILOM

SPX86-8000-VR

Level 2 Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48969

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_W4_1

ILOM

SPX86-8000-W4

Level 2 Data Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48970

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_XQ_1

ILOM

SPX86-8000-XQ

Level 2 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48971

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_YC_1

ILOM

SPX86-8000-YC

Level 2 Instruction Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48972

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_0Q_1

ILOM

SPX86-8001-0Q

Level 2 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48973

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_1C_1

ILOM

SPX86-8001-1C

Level 2 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48974

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_2R_1

ILOM

SPX86-8001-2R

Memory Controller fault

CASE

2

Modified

28-Apr-14

 

48975

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_34_1

ILOM

SPX86-8001-34

Initialization failure of the Intel Quickpath Interconnect Physical Layer, Link Layer, or Protocol Layer

CASE

2

Modified

28-Apr-14

 

48976

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_4X_1

ILOM

SPX86-8001-4X

Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48977

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_ME_1

ILOM

SPX86-8001-ME

 

CASE

2

Modified

28-Apr-14

 

48978

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_QX_1

ILOM

SPX86-8001-QX

Memory DIMM Temperature Sensor Failed

CASE

2

Modified

28-Apr-14

 

48979

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_TS_1

ILOM

SPX86-8001-TS

Memory DIMM Failure During Training

CASE

2

Modified

28-Apr-14

 

48980

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_U5_1

ILOM

SPX86-8001-U5

Memory Uncorrectable ECC Fault

CASE

2

Modified

28-Apr-14

 

48982

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_2J_1

ILOM

SPX86-8002-2J

Power to server not available

CASE

2

Modified

28-Apr-14

 

48985

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_A3_1

ILOM

SPX86-8002-A3

Potentiometers not responding.

CASE

2

Modified

28-Apr-14

 

48988

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_Y5_1

ILOM

SPX86-8002-Y5

Power Supply Internal Failure

CASE

2

Modified

28-Apr-14

 

48989

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_3A_1

ILOM

SPX86-8003-3A

Fan Column Failure

CASE

2

Modified

28-Apr-14

 

48991

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_73_1

ILOM

SPX86-8003-73

Lack of AC input power.

CASE

3

Modified

28-Apr-14

 

48992

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_9Q_1

ILOM

SPX86-8003-9Q

Component temp exceeded

CASE

2

Modified

28-Apr-14

 

48993

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_CR_1

ILOM

SPX86-8003-CR

Home Agent error

CASE

2

Modified

28-Apr-14

 

49079

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_2Y_1_EXA

ILOM

SPX86-8000-2Y

Fan Column Failure

CASE

2

Modified

28-Apr-14

 

50632

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_2Y_1

ILOM

SPX86-8000-2Y

Fan Column Failure

CASE

2

Modified

08-Sep-14

 

50633

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_D2_1

ILOM

SPX86-8003-D2

Intel QPI Link is Slow

CASE

2

Modified

08-Sep-14

 

50634

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_EX_1

ILOM

SPX86-8003-EX

Intel QPI Link Training Failure

CASE

2

Modified

08-Sep-14

 

50635

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_FE_1

ILOM

SPX86-8003-FE

Memory Controller Uncorrectable Error

CASE

2

Modified

08-Sep-14

 

50636

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_GJ_1

ILOM

SPX86-8003-GJ

Memory Scrubbing UE

CASE

2

Modified

08-Sep-14

 

50637

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_HA_1

ILOM

SPX86-8003-HA

Unknown Error from QPI Reference Code

CASE

2

Modified

08-Sep-14

 

50638

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_K5_1

ILOM

SPX86-8003-K5

Intel Thermtrip Failure

CASE

2

Modified

08-Sep-14

 

50639

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_LS_1

ILOM

SPX86-8003-LS

IIO core fatal fault

CASE

2

Modified

08-Sep-14

 

50640

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_M3_1

ILOM

SPX86-8003-M3

IIO IRP Fatal Error

CASE

2

Modified

08-Sep-14

 

50641

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_NY_1

ILOM

SPX86-8003-NY

IIO Miscellaneous Fatal Error

CASE

2

Modified

08-Sep-14

 

50642

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_QH_1

ILOM

SPX86-8003-QH

IIO PCIE fault in downstream devices

CASE

2

Modified

08-Sep-14

 

50643

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_RR_1

ILOM

SPX86-8003-RR

IIO PCIE Fatal Error

CASE

2

Modified

08-Sep-14

 

50644

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_S4_1

ILOM

SPX86-8003-S4

IIO PCIE Error in Downstream Leaf Devices

CASE

2

Modified

08-Sep-14

 

50645

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_TQ_1

ILOM

SPX86-8003-TQ

IIO PCIE Error in Root Port Device

CASE

2

Modified

08-Sep-14

 

50646

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_UC_1

ILOM

SPX86-8003-UC

IIO VT-d Fatal Error

CASE

2

Modified

08-Sep-14

 

50647

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_0D_1

ILOM

SPX86-8004-0D

DIMM disabled due to memtest errors

CASE

2

Modified

08-Sep-14

 

50648

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_1H_1

ILOM

SPX86-8004-1H

Dimm Failed Memtest

CASE

2

Modified

08-Sep-14

 

50649

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_6A_1

ILOM

SPX86-8004-6A

DIMM can't run at speeds required by platform

CASE

2

Modified

08-Sep-14

 

50650

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_7P_1

ILOM

SPX86-8004-7P

Throttling not sufficient for this DIMM

CASE

2

Modified

08-Sep-14

 

50651

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_8X_1

ILOM

SPX86-8004-8X

Single Symbol error Found in DIMM Training

CASE

2

Modified

08-Sep-14

 

50652

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_AJ_1

ILOM

SPX86-8004-AJ

Unknown Error from Intel Memory Reference Code

CASE

2

Modified

08-Sep-14

 

50653

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_CE_1

ILOM

SPX86-8004-CE

Fault due to excessive memory correctable errors

CASE

2

Modified

08-Sep-14

 

50654

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_DQ_1

ILOM

SPX86-8004-DQ

BIOS Hangs due to Intel ME Failure

CASE

2

Modified

08-Sep-14

 

50655

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_EC_1

ILOM

SPX86-8004-EC

Catastrophic Error Events

CASE

2

Modified

08-Sep-14

 

50656

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_FR_1

ILOM

SPX86-8004-FR

Persistent Catastrophic Error

CASE

2

Modified

08-Sep-14

 

50657

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_G4_1

ILOM

SPX86-8004-G4

Failure of Power Source

CASE

2

Modified

08-Sep-14

 

50658

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8001_EE

ILOM

INTEL-8001-EE

Memory Bad Parity

CASE

2

Modified

08-Sep-14

 

50659

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8001_J5

ILOM

INTEL-8001-J5

Memory Mirror Broken

CASE

2

Modified

08-Sep-14

 

50660

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8001_G2

ILOM

INTEL-8001-G2

Spare memory error

CASE

2

Modified

08-Sep-14

 

50661

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8001_AQ

ILOM

INTEL-8001-AQ

Multibit memory module errors

CASE

2

Modified

08-Sep-14

 

50662

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8001_94

ILOM

INTEL-8001-94

Memory module correctable errors exceeding acceptable levels

CASE

2

Modified

08-Sep-14

 

50664

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8002_1Y

ILOM

INTEL-8002-1Y

A Middle Level Cache ECC Uncorrectable Error

CASE

2

Modified

08-Sep-14

 

50665

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8002_2D

ILOM

INTEL-8002-2D

A Last Level Cache ECC Uncorrectable Error

CASE

2

Modified

08-Sep-14

 

50666

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_1J

ILOM

INTEL-8000-1J

An internal error has been encountered on this cpu.

CASE

2

Modified

08-Sep-14

 

50667

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_22

ILOM

INTEL-8000-22

A level 0 cache on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50668

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_3X

ILOM

INTEL-8000-3X

A level 1 cache on this cpu is faulty

CASE

2

Modified

08-Sep-14

 

50669

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_44

ILOM

INTEL-8000-44

A level 2 cache on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50670

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_5R

ILOM

INTEL-8000-5R

A cache on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50671

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_6C

ILOM

INTEL-8000-6C

A level 0 Data TLB on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50672

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_7Q

ILOM

INTEL-8000-7Q

A level 1 Data TLB on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50673

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_8Y

ILOM

INTEL-8000-8Y

A level 2 Data TLB on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50674

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_93

ILOM

INTEL-8000-93

A Data TLB on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50675

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_AH

ILOM

INTEL-8000-AH

A level 0 Instruction TLB on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50676

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_CD

ILOM

INTEL-8000-CD

A level 1 Instruction TLB on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50677

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_DP

ILOM

INTEL-8000-DP

A level 2 Instruction TLB on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50678

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_EA

ILOM

INTEL-8000-EA

An Instruction TLB on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50679

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_FS

ILOM

INTEL-8000-FS

A level 0 TLB on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50680

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_G5

ILOM

INTEL-8000-G5

A level 1 TLB on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50681

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_HX

ILOM

INTEL-8000-HX

A level 2 TLB on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50682

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_J2

ILOM

INTEL-8000-J2

A TLB on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50683

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_KJ

ILOM

INTEL-8000-KJ

A level 0 Data Cache on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50684

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_LE

ILOM

INTEL-8000-LE

A level 1 Data Cache on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50685

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_MQ

ILOM

INTEL-8000-MQ

A level 2 Data Cache on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50686

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_NC

ILOM

INTEL-8000-NC

A Data Cache on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50687

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_PR

ILOM

INTEL-8000-PR

A level 0 Instruction Cache on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50688

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_Q4

ILOM

INTEL-8000-Q4

A level 1 Instruction Cache on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50689

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_RD

ILOM

INTEL-8000-RD

A level 2 Instruction Cache on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50690

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_SH

ILOM

INTEL-8000-SH

An Instruction Cache on this cpu is faulty.

CASE

2

Modified

08-Sep-14

 

50691

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.DISK_8000_0X

ILOM

DISK-8000-0X

Predictive Disk Failure Imminent

CASE

2

Modified

08-Sep-14

 

50692

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.DISK_8000_12

ILOM

DISK-8000-12

Disk Temperature Exceeded Threshold

CASE

2

Modified

08-Sep-14

 

50693

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.DISK_8000_2J

ILOM

DISK-8000-2J

Disk Self-Test Failure

CASE

2

Modified

08-Sep-14

 

50694

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.DISK_8000_3E

ILOM

DISK-8000-3E

SCSI fault for device

CASE

2

Modified

08-Sep-14

 

50695

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.DISK_8000_4Q

ILOM

DISK-8000-4Q

SCSI fault for media

CASE

2

Modified

08-Sep-14

 

50834

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_0A_EXA

ILOM

PCIEX-8000-0A

A problem was detected for a PCIEX device.

CASE

2

New

08-Sep-14

 

50835

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_3S_EXA

ILOM

PCIEX-8000-3S

A problem has been detected on one of the specified devices or connecting buses.

CASE

2

New

08-Sep-14

 

50836

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_8R_EXA

ILOM

PCIEX-8000-8R

The transmitting device sent an invalid request.

CASE

2

New

08-Sep-14

 

50837

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_DJ_EXA

ILOM

PCIEX-8000-DJ

A problem has been detected on one of the specified devices or connecting buses.

CASE

2

New

08-Sep-14

 

50838

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_J5_EXA

ILOM

PCIEX-8000-J5

Too many recovered internal errors have been detected within the specified PCIEX device.

CASE

2

New

08-Sep-14

 

50839

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_KP_EXA

ILOM

PCIEX-8000-KP

Too many recovered bus errors have been detected.

CASE

2

New

08-Sep-14

 

50840

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_MH_EXA

ILOM

PCIEX-8000-MH

Too many recovered errors have been detected, which indicates a problem with the specified device.

CASE

2

New

08-Sep-14

 

50841

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_SQ_EXA

ILOM

PCIEX-8000-SQ

An uncorrectable error was detected in the PCIe Root Complex.

CASE

3

New

08-Sep-14

 

50842

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_V2_EXA

ILOM

PCIEX-8000-V2

A decrease in PCIe link bandwidth has been detected.

CASE

2

New

08-Sep-14

 

50843

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_YJ_EXA

ILOM

PCIEX-8000-YJ

Too many recovered bus errors have been detected.

CASE

2

New

08-Sep-14

 

14238

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.INTEL_8002_03_EXA

ILOM

INTEL-8002-03

Uncorrectable SW recoverable memory scrubbing error

DRAFT

3

 

 

 

50663

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.INTEL_8002_03

ILOM

INTEL-8002-03

Uncorrectable SW recoverable memory scrubbing error

DRAFT

3

Modified

08-Sep-14

 

14173

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_XH_1_EXA

ILOM

SPX86-8001-XH

Potential candidate for a draft SR

NO_CASE

 

 

 

 

14177

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_3E_1_EXA

ILOM

SPX86-8002-3E

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

14178

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_4Q_1_EXA

ILOM

SPX86-8002-4Q

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

14192

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_NR_1_EXA

ILOM

SPX86-8002-NR

Dave to research - KA indicates that fault will usually be caused by insufficient power. Engineering has determined that this event will likely be caused by power budget configuration.

NO_CASE

 

 

 

 

14193

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_PC_1_EXA

ILOM

SPX86-8002-PC

KA indicates that this event can be caused by shutdown. The fourth suggested action is to replace MB/Blade.

NO_CASE

 

 

 

 

14199

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_4H_1_EXA

ILOM

SPX86-8003-4H

Power Supply unsupported

NO_CASE

 

 

 

 

14229

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_HY_1_EXA

ILOM

SPX86-8004-HY

Config issue not actionable

NO_CASE

 

 

 

 

14230

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_J3_1_EXA

ILOM

SPX86-8004-J3

Config issue not actionable

NO_CASE

 

 

 

 

14231

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_KH_1_EXA

ILOM

SPX86-8004-KH

Config issue not actionable

NO_CASE

 

 

 

 

14232

ODA-X3-2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8004_LD_1_EXA

ILOM

SPX86-8004-LD

FW corrupt not actionable

NO_CASE

 

 

 

 

23316

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_HY_1

ILOM

SPX86-8004-HY

Config issue not actionable

NO_CASE

 

 

 

 

23317

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_J3_1

ILOM

SPX86-8004-J3

Config issue not actionable

NO_CASE

 

 

 

 

23318

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_KH_1

ILOM

SPX86-8004-KH

Config issue not actionable

NO_CASE

 

 

 

 

23319

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_LD_1

ILOM

SPX86-8004-LD

FW corrupt not actionable

NO_CASE

 

 

 

 

48981

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_XH_1

ILOM

SPX86-8001-XH

 

NO_CASE

 

Modified

28-Apr-14

 

48983

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_3E_1

ILOM

SPX86-8002-3E

 

NO_CASE

 

Modified

28-Apr-14

 

48984

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_4Q_1

ILOM

SPX86-8002-4Q

 

NO_CASE

 

Modified

28-Apr-14

 

48986

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_NR_1

ILOM

SPX86-8002-NR

 

NO_CASE

 

Modified

28-Apr-14

 

48987

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_PC_1

ILOM

SPX86-8002-PC

 

NO_CASE

 

Modified

28-Apr-14

 

48990

ODA-X3-2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_4H_1

ILOM

SPX86-8003-4H

Power Supply unsupported

NO_CASE

 

Modified

28-Apr-14

 


X4-2

Rule ID

Product

Rule Name

Source

Knowledge Link

Description

Action

Severity

History

Last Update Date

Reason

14475

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_2Y_EXA_X4_Diag

ILOM

SPX86-8000-2Y

Fan Column Failure

CASE

2

 

 

 

14476

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_33_EXA_X4_Diag

ILOM

SPX86-8000-33

Probable chassis Fan or Power Supply Fan failure

CASE

3

 

 

 

14477

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_AE_EXA_X4_Diag

ILOM

SPX86-8000-AE

Cache fault on Processor

CASE

2

 

 

 

14478

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_CJ_EXA_X4_Diag

ILOM

SPX86-8000-CJ

Data Cache Fault on Processor

CASE

2

 

 

 

14479

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_DC_EXA_X4_Diag

ILOM

SPX86-8000-DC

Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14480

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_EQ_EXA_X4_Diag

ILOM

SPX86-8000-EQ

Instruction Cache Fault on Processor

CASE

2

 

 

 

14481

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_F4_EXA_X4_Diag

ILOM

SPX86-8000-F4

Internal Processor Fault

CASE

2

 

 

 

14482

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_GR_EXA_X4_Diag

ILOM

SPX86-8000-GR

Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14483

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_H3_EXA_X4_Diag

ILOM

SPX86-8000-H3

Level 0 Cache Fault on Processor

CASE

2

 

 

 

14484

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_JY_EXA_X4_Diag

ILOM

SPX86-8000-JY

Level 0 Data Cache Fault on Processor

CASE

2

 

 

 

14485

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_KD_EXA_X4_Diag

ILOM

SPX86-8000-KD

Level 0 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14486

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_LH_EXA_X4_Diag

ILOM

SPX86-8000-LH

Level 0 Instruction Cache Fault on Processor

CASE

2

 

 

 

14487

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_MA_EXA_X4_Diag

ILOM

SPX86-8000-MA

Level 0 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14488

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_NP_EXA_X4_Diag

ILOM

SPX86-8000-NP

Level 0 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14489

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_P5_EXA_X4_Diag

ILOM

SPX86-8000-P5

Level 1 Cache Fault on Processor

CASE

2

 

 

 

14490

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_QS_EXA_X4_Diag

ILOM

SPX86-8000-QS

Level 1 Data Cache Fault on Processor

CASE

2

 

 

 

14491

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_RJ_EXA_X4_Diag

ILOM

SPX86-8000-RJ

Level 1 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14492

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_SE_EXA_X4_Diag

ILOM

SPX86-8000-SE

Level 1 Instruction Cache Fault on Processor

CASE

2

 

 

 

14493

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_TX_EXA_X4_Diag

ILOM

SPX86-8000-TX

Level 1 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14494

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_U2_EXA_X4_Diag

ILOM

SPX86-8000-U2

Level 1 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14495

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_VR_EXA_X4_Diag

ILOM

SPX86-8000-VR

Level 2 Cache Fault on Processor

CASE

2

 

 

 

14496

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_W4_EXA_X4_Diag

ILOM

SPX86-8000-W4

Level 2 Data Cache Fault on Processor

CASE

2

 

 

 

14497

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_XQ_EXA_X4_Diag

ILOM

SPX86-8000-XQ

Level 2 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14498

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8000_YC_EXA_X4_Diag

ILOM

SPX86-8000-YC

Level 2 Instruction Cache Fault on Processor

CASE

2

 

 

 

14499

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8001_0Q_EXA_X4_Diag

ILOM

SPX86-8001-0Q

Level 2 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14500

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8001_1C_EXA_X4_Diag

ILOM

SPX86-8001-1C

Level 2 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14501

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8001_2R_EXA_X4_Diag

ILOM

SPX86-8001-2R

Memory Controller fault

CASE

2

 

 

 

14502

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8001_34_EXA_X4_Diag

ILOM

SPX86-8001-34

Initialization failure of the Intel Quickpath Interconnect Physical Layer, Link Layer, or Protocol Layer

CASE

2

 

 

 

14503

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8001_4X_EXA_X4_Diag

ILOM

SPX86-8001-4X

Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14504

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8001_ME_EXA_X4_Diag

ILOM

SPX86-8001-ME

Reviewed 10/28/2011 – Event does not indicate that a part has failed. Added to SAMS reporting for further tracking. Message ID: SPX86-8001-ME indicates that the ILOM fault manager has received\

CASE

2

 

 

 

14505

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8001_QX_EXA_X4_Diag

ILOM

SPX86-8001-QX

Memory DIMM Temperature Sensor Failed

CASE

2

 

 

 

14506

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8001_TS_EXA_X4_Diag

ILOM

SPX86-8001-TS

Memory DIMM Failure During Training

CASE

2

 

 

 

14507

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8001_U5_EXA_X4_Diag

ILOM

SPX86-8001-U5

Memory Uncorrectable ECC Fault

CASE

2

 

 

 

14509

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8002_2J_EXA_X4_Diag

ILOM

SPX86-8002-2J

Power to server not available

CASE

2

 

 

 

14512

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8002_A3_EXA_X4_Diag

ILOM

SPX86-8002-A3

Potentiometers not responding.

CASE

2

 

 

 

14515

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8002_Y5_EXA_X4_Diag

ILOM

SPX86-8002-Y5

Power Supply Internal Failure

CASE

2

 

 

 

14516

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_3A_EXA_X4_Diag

ILOM

SPX86-8003-3A

Fan Column Failure

CASE

2

 

 

 

14519

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_9Q_EXA_X4_Diag

ILOM

SPX86-8003-9Q

Component temp exceeded

CASE

2

 

 

 

14520

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_CR_EXA_X4_Diag

ILOM

SPX86-8003-CR

Home Agent error

CASE

2

 

 

 

14521

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_D2_EXA_X4_Diag

ILOM

SPX86-8003-D2

Intel QPI Link is Slow

CASE

2

 

 

 

14522

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_EX_EXA_X4_Diag

ILOM

SPX86-8003-EX

Intel QPI Link Training Failure

CASE

2

 

 

 

14523

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_FE_EXA_X4_Diag

ILOM

SPX86-8003-FE

Memory Controller Uncorrectable Error

CASE

2

 

 

 

14524

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_GJ_EXA_X4_Diag

ILOM

SPX86-8003-GJ

Memory Scrubbing UE

CASE

2

 

 

 

14525

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_HA_EXA_X4_Diag

ILOM

SPX86-8003-HA

Unknown Error from QPI Reference Code

CASE

2

 

 

 

14526

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_K5_EXA_X4_Diag

ILOM

SPX86-8003-K5

Intel Thermtrip Failure

CASE

2

 

 

 

14527

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_LS_EXA_X4_Diag

ILOM

SPX86-8003-LS

IIO core fatal fault

CASE

2

 

 

 

14528

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_M3_EXA_X4_Diag

ILOM

SPX86-8003-M3

IIO IRP Fatal Error

CASE

2

 

 

 

14529

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_NY_EXA_X4_Diag

ILOM

SPX86-8003-NY

IIO Miscellaneous Fatal Error

CASE

2

 

 

 

14531

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_QH_EXA_X4_Diag

ILOM

SPX86-8003-QH

IIO PCIE fault in downstream devices

CASE

2

 

 

 

14532

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_RR_EXA_X4_Diag

ILOM

SPX86-8003-RR

IIO PCIE Fatal Error

CASE

2

 

 

 

14533

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_S4_EXA_X4_Diag

ILOM

SPX86-8003-S4

IIO PCIE Error in Downstream Leaf Devices

CASE

2

 

 

 

14534

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_TQ_EXA_X4_Diag

ILOM

SPX86-8003-TQ

IIO PCIE Error in Root Port Device

CASE

2

 

 

 

14535

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_UC_EXA_X4_Diag

ILOM

SPX86-8003-UC

IIO VT-d Fatal Error

CASE

2

 

 

 

14536

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_0D_EXA_X4_Diag

ILOM

SPX86-8004-0D

DIMM disabled due to memtest errors

CASE

2

 

 

 

14537

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_1H_EXA_X4_Diag

ILOM

SPX86-8004-1H

Dimm Failed Memtest

CASE

2

 

 

 

14538

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_6A_EXA_X4_Diag

ILOM

SPX86-8004-6A

DIMM can't run at speeds required by platform

CASE

2

 

 

 

14539

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_7P_EXA_X4_Diag

ILOM

SPX86-8004-7P

Throttling not sufficient for this DIMM

CASE

2

 

 

 

14540

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_8X_EXA_X4_Diag

ILOM

SPX86-8004-8X

Single Symbol error Found in DIMM Training

CASE

2

 

 

 

14541

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_AJ_EXA_X4_Diag

ILOM

SPX86-8004-AJ

Unknown Error from Intel Memory Reference Code

CASE

2

 

 

 

14542

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_CE_EXA_X4_Diag

ILOM

SPX86-8004-CE

Fault due to excessive memory correctable errors

CASE

2

 

 

 

14543

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_DQ_EXA_X4_Diag

ILOM

SPX86-8004-DQ

BIOS Hangs due to Intel ME Failure

CASE

2

 

 

 

14544

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_EC_EXA_X4_Diag

ILOM

SPX86-8004-EC

Catastrophic Error Events

CASE

2

 

 

 

14545

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_FR_EXA_X4_Diag

ILOM

SPX86-8004-FR

Persistent Catastrophic Error

CASE

2

 

 

 

14546

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_G4_EXA_X4_Diag

ILOM

SPX86-8004-G4

Failure of Power Source

CASE

2

 

 

 

14551

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_MP_EXA_X4_Diag

ILOM

SPX86-8004-MP

A serial peripheral interface error (SPI) during a BIOS update or UEFI config backup/restore operation has occurred.\" The server will be unable to power on

CASE

2

 

 

 

14552

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_NA_EXA_X4_Diag

ILOM

SPX86-8004-NA

A firmware or hardware error with the power control unit (PCU) of a CPU has occurred Fatal machine check error will result in a system reset or power off

CASE

2

 

 

 

14553

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_PS_EXA_X4_Diag

ILOM

SPX86-8004-PS

A memory DIMM failure occurred during initialization

CASE

2

 

 

 

14557

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_T2_EXA_X4_Diag

ILOM

SPX86-8004-T2

A CPU timeout has occurred. System will panic and reset.

CASE

2

 

 

 

14558

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8001_EE_EXA_X4_Diag

ILOM

INTEL-8001-EE

Memory Bad Parity

CASE

2

 

 

 

14559

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8001_J5_EXA_X4_Diag

ILOM

INTEL-8001-J5

Memory Mirror Broken

CASE

2

 

 

 

14560

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8001_G2_EXA_X4_Diag

ILOM

INTEL-8001-G2

Spare memory error

CASE

2

 

 

 

14561

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8001_AQ_EXA_X4_Diag

ILOM

INTEL-8001-AQ

Multibit memory module errors

CASE

2

 

 

 

14562

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8001_94_EXA_X4_Diag

ILOM

INTEL-8001-94

Memory module correctable errors exceeding acceptable levels

CASE

2

 

 

 

14564

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8002_1Y_EXA_X4_Diag

ILOM

INTEL-8002-1Y

A Middle Level Cache ECC Uncorrectable Error

CASE

2

 

 

 

14565

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8002_2D_EXA_X4_Diag

ILOM

INTEL-8002-2D

A Last Level Cache ECC Uncorrectable Error

CASE

2

 

 

 

14566

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_1J_EXA_X4_Diag

ILOM

INTEL-8000-1J

An internal error has been encountered on this cpu.

CASE

2

 

 

 

14567

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_22_EXA_X4_Diag

ILOM

INTEL-8000-22

A level 0 cache on this cpu is faulty.

CASE

2

 

 

 

14568

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_3X_EXA_X4_Diag

ILOM

INTEL-8000-3X

A level 1 cache on this cpu is faulty

CASE

2

 

 

 

14569

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_44_EXA_X4_Diag

ILOM

INTEL-8000-44

A level 2 cache on this cpu is faulty.

CASE

2

 

 

 

14570

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_5R_EXA_X4_Diag

ILOM

INTEL-8000-5R

A cache on this cpu is faulty.

CASE

2

 

 

 

14571

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_6C_EXA_X4_Diag

ILOM

INTEL-8000-6C

A level 0 Data TLB on this cpu is faulty.

CASE

2

 

 

 

14572

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_7Q_EXA_X4_Diag

ILOM

INTEL-8000-7Q

A level 1 Data TLB on this cpu is faulty.

CASE

2

 

 

 

14573

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_8Y_EXA_X4_Diag

ILOM

INTEL-8000-8Y

A level 2 Data TLB on this cpu is faulty.

CASE

2

 

 

 

14574

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_93_EXA_X4_Diag

ILOM

INTEL-8000-93

A Data TLB on this cpu is faulty.

CASE

2

 

 

 

14575

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_AH_EXA_X4_Diag

ILOM

INTEL-8000-AH

A level 0 Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

14576

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_CD_EXA_X4_Diag

ILOM

INTEL-8000-CD

A level 1 Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

14577

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_DP_EXA_X4_Diag

ILOM

INTEL-8000-DP

A level 2 Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

14578

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_EA_EXA_X4_Diag

ILOM

INTEL-8000-EA

An Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

14579

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_FS_EXA_X4_Diag

ILOM

INTEL-8000-FS

A level 0 TLB on this cpu is faulty.

CASE

2

 

 

 

14580

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_G5_EXA_X4_Diag

ILOM

INTEL-8000-G5

A level 1 TLB on this cpu is faulty.

CASE

2

 

 

 

14581

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_HX_EXA_X4_Diag

ILOM

INTEL-8000-HX

A level 2 TLB on this cpu is faulty.

CASE

2

 

 

 

14582

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_J2_EXA_X4_Diag

ILOM

INTEL-8000-J2

A TLB on this cpu is faulty.

CASE

2

 

 

 

14583

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_KJ_EXA_X4_Diag

ILOM

INTEL-8000-KJ

A level 0 Data Cache on this cpu is faulty.

CASE

2

 

 

 

14584

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_LE_EXA_X4_Diag

ILOM

INTEL-8000-LE

A level 1 Data Cache on this cpu is faulty.

CASE

2

 

 

 

14585

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_MQ_EXA_X4_Diag

ILOM

INTEL-8000-MQ

A level 2 Data Cache on this cpu is faulty.

CASE

2

 

 

 

14586

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_NC_EXA_X4_Diag

ILOM

INTEL-8000-NC

A Data Cache on this cpu is faulty.

CASE

2

 

 

 

14587

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_PR_EXA_X4_Diag

ILOM

INTEL-8000-PR

A level 0 Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

14588

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_Q4_EXA_X4_Diag

ILOM

INTEL-8000-Q4

A level 1 Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

14589

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_RD_EXA_X4_Diag

ILOM

INTEL-8000-RD

A level 2 Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

14590

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8000_SH_EXA_X4_Diag

ILOM

INTEL-8000-SH

An Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

14591

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.DISK_8000_0X_EXA_X4_Diag

ILOM

DISK-8000-0X

Predictive Disk Failure Imminent

CASE

2

 

 

 

14592

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.DISK_8000_12_EXA_X4_Diag

ILOM

DISK-8000-12

Disk Temperature Exceeded Threshold

CASE

2

 

 

 

14593

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.DISK_8000_2J_EXA_X4_Diag

ILOM

DISK-8000-2J

Disk Self-Test Failure

CASE

2

 

 

 

14594

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.DISK_8000_3E_EXA_X4_Diag

ILOM

DISK-8000-3E

SCSI fault for device

CASE

2

 

 

 

14595

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.DISK_8000_4Q_EXA_X4_Diag

ILOM

DISK-8000-4Q

SCSI fault for media

CASE

2

 

 

 

22794

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_2Y_X4_Diag

ILOM

SPX86-8000-2Y

Fan Column Failure

CASE

2

 

 

 

22795

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_33_X4_Diag

ILOM

SPX86-8000-33

Probable chassis Fan or Power Supply Fan failure

CASE

3

 

 

 

22796

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_AE_X4_Diag

ILOM

SPX86-8000-AE

Cache fault on Processor

CASE

2

 

 

 

22797

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_CJ_X4_Diag

ILOM

SPX86-8000-CJ

Data Cache Fault on Processor

CASE

2

 

 

 

22798

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_DC_X4_Diag

ILOM

SPX86-8000-DC

Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

22799

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_EQ_X4_Diag

ILOM

SPX86-8000-EQ

Instruction Cache Fault on Processor

CASE

2

 

 

 

22800

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_F4_X4_Diag

ILOM

SPX86-8000-F4

Internal Processor Fault

CASE

2

 

 

 

22801

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_GR_X4_Diag

ILOM

SPX86-8000-GR

Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

22802

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_H3_X4_Diag

ILOM

SPX86-8000-H3

Level 0 Cache Fault on Processor

CASE

2

 

 

 

22803

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_JY_X4_Diag

ILOM

SPX86-8000-JY

Level 0 Data Cache Fault on Processor

CASE

2

 

 

 

22804

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_KD_X4_Diag

ILOM

SPX86-8000-KD

Level 0 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

22805

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_LH_X4_Diag

ILOM

SPX86-8000-LH

Level 0 Instruction Cache Fault on Processor

CASE

2

 

 

 

22806

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_MA_X4_Diag

ILOM

SPX86-8000-MA

Level 0 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

22807

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_NP_X4_Diag

ILOM

SPX86-8000-NP

Level 0 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

22808

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_P5_X4_Diag

ILOM

SPX86-8000-P5

Level 1 Cache Fault on Processor

CASE

2

 

 

 

22809

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_QS_X4_Diag

ILOM

SPX86-8000-QS

Level 1 Data Cache Fault on Processor

CASE

2

 

 

 

22810

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_RJ_X4_Diag

ILOM

SPX86-8000-RJ

Level 1 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

22811

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_SE_X4_Diag

ILOM

SPX86-8000-SE

Level 1 Instruction Cache Fault on Processor

CASE

2

 

 

 

22812

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_TX_X4_Diag

ILOM

SPX86-8000-TX

Level 1 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

22813

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_U2_X4_Diag

ILOM

SPX86-8000-U2

Level 1 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

22814

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_VR_X4_Diag

ILOM

SPX86-8000-VR

Level 2 Cache Fault on Processor

CASE

2

 

 

 

22815

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_W4_X4_Diag

ILOM

SPX86-8000-W4

Level 2 Data Cache Fault on Processor

CASE

2

 

 

 

22816

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_XQ_X4_Diag

ILOM

SPX86-8000-XQ

Level 2 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

22817

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_YC_X4_Diag

ILOM

SPX86-8000-YC

Level 2 Instruction Cache Fault on Processor

CASE

2

 

 

 

22818

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_0Q_X4_Diag

ILOM

SPX86-8001-0Q

Level 2 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

22819

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_1C_X4_Diag

ILOM

SPX86-8001-1C

Level 2 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

22820

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_2R_X4_Diag

ILOM

SPX86-8001-2R

Memory Controller fault

CASE

2

 

 

 

22821

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_34_X4_Diag

ILOM

SPX86-8001-34

Initialization failure of the Intel Quickpath Interconnect Physical Layer, Link Layer, or Protocol Layer

CASE

2

 

 

 

22822

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_4X_X4_Diag

ILOM

SPX86-8001-4X

Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

22823

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_ME_X4_Diag

ILOM

SPX86-8001-ME

Reviewed 10/28/2011 – Event does not indicate that a part has failed. Added to SAMS reporting for further tracking. Message ID: SPX86-8001-ME indicates that the ILOM fault manager has received\

CASE

2

 

 

 

22824

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_QX_X4_Diag

ILOM

SPX86-8001-QX

Memory DIMM Temperature Sensor Failed

CASE

2

 

 

 

22825

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_TS_X4_Diag

ILOM

SPX86-8001-TS

Memory DIMM Failure During Training

CASE

2

 

 

 

22826

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_U5_X4_Diag

ILOM

SPX86-8001-U5

Memory Uncorrectable ECC Fault

CASE

2

 

 

 

22828

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_2J_X4_Diag

ILOM

SPX86-8002-2J

Power to server not available

CASE

2

 

 

 

22831

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_A3_X4_Diag

ILOM

SPX86-8002-A3

Potentiometers not responding.

CASE

2

 

 

 

22834

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_Y5_X4_Diag

ILOM

SPX86-8002-Y5

Power Supply Internal Failure

CASE

2

 

 

 

22835

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_3A_X4_Diag

ILOM

SPX86-8003-3A

Fan Column Failure

CASE

2

 

 

 

22838

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_9Q_X4_Diag

ILOM

SPX86-8003-9Q

Component temp exceeded

CASE

2

 

 

 

22839

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_CR_X4_Diag

ILOM

SPX86-8003-CR

Home Agent error

CASE

2

 

 

 

22840

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_D2_X4_Diag

ILOM

SPX86-8003-D2

Intel QPI Link is Slow

CASE

2

 

 

 

22841

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_EX_X4_Diag

ILOM

SPX86-8003-EX

Intel QPI Link Training Failure

CASE

2

 

 

 

22842

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_FE_X4_Diag

ILOM

SPX86-8003-FE

Memory Controller Uncorrectable Error

CASE

2

 

 

 

22843

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_GJ_X4_Diag

ILOM

SPX86-8003-GJ

Memory Scrubbing UE

CASE

2

 

 

 

22844

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_HA_X4_Diag

ILOM

SPX86-8003-HA

Unknown Error from QPI Reference Code

CASE

2

 

 

 

22845

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_K5_X4_Diag

ILOM

SPX86-8003-K5

Intel Thermtrip Failure

CASE

2

 

 

 

22846

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_LS_X4_Diag

ILOM

SPX86-8003-LS

IIO core fatal fault

CASE

2

 

 

 

22847

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_M3_X4_Diag

ILOM

SPX86-8003-M3

IIO IRP Fatal Error

CASE

2

 

 

 

22848

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_NY_X4_Diag

ILOM

SPX86-8003-NY

IIO Miscellaneous Fatal Error

CASE

2

 

 

 

22850

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_QH_X4_Diag

ILOM

SPX86-8003-QH

IIO PCIE fault in downstream devices

CASE

2

 

 

 

22851

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_RR_X4_Diag

ILOM

SPX86-8003-RR

IIO PCIE Fatal Error

CASE

2

 

 

 

22852

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_S4_X4_Diag

ILOM

SPX86-8003-S4

IIO PCIE Error in Downstream Leaf Devices

CASE

2

 

 

 

22853

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_TQ_X4_Diag

ILOM

SPX86-8003-TQ

IIO PCIE Error in Root Port Device

CASE

2

 

 

 

22854

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_UC_X4_Diag

ILOM

SPX86-8003-UC

IIO VT-d Fatal Error

CASE

2

 

 

 

22855

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_0D_X4_Diag

ILOM

SPX86-8004-0D

DIMM disabled due to memtest errors

CASE

2

 

 

 

22856

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_1H_X4_Diag

ILOM

SPX86-8004-1H

Dimm Failed Memtest

CASE

2

 

 

 

22857

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_6A_X4_Diag

ILOM

SPX86-8004-6A

DIMM can't run at speeds required by platform

CASE

2

 

 

 

22858

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_7P_X4_Diag

ILOM

SPX86-8004-7P

Throttling not sufficient for this DIMM

CASE

2

 

 

 

22859

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_8X_X4_Diag

ILOM

SPX86-8004-8X

Single Symbol error Found in DIMM Training

CASE

2

 

 

 

22860

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_AJ_X4_Diag

ILOM

SPX86-8004-AJ

Unknown Error from Intel Memory Reference Code

CASE

2

 

 

 

22861

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_CE_X4_Diag

ILOM

SPX86-8004-CE

Fault due to excessive memory correctable errors

CASE

2

 

 

 

22862

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_DQ_X4_Diag

ILOM

SPX86-8004-DQ

BIOS Hangs due to Intel ME Failure

CASE

2

 

 

 

22863

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_EC_X4_Diag

ILOM

SPX86-8004-EC

Catastrophic Error Events

CASE

2

 

 

 

22864

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_FR_X4_Diag

ILOM

SPX86-8004-FR

Persistent Catastrophic Error

CASE

2

 

 

 

22865

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_G4_X4_Diag

ILOM

SPX86-8004-G4

Failure of Power Source

CASE

2

 

 

 

22870

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_MP_X4_Diag

ILOM

SPX86-8004-MP

A serial peripheral interface error (SPI) during a BIOS update or UEFI config backup/restore operation has occurred.\" The server will be unable to power on

CASE

2

 

 

 

22871

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_NA_X4_Diag

ILOM

SPX86-8004-NA

A firmware or hardware error with the power control unit (PCU) of a CPU has occurred Fatal machine check error will result in a system reset or power off

CASE

2

 

 

 

22872

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_PS_X4_Diag

ILOM

SPX86-8004-PS

A memory DIMM failure occurred during initialization

CASE

2

 

 

 

22876

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_T2_X4_Diag

ILOM

SPX86-8004-T2

A CPU timeout has occurred. System will panic and reset.

CASE

2

 

 

 

22877

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8001_EE_X4_Diag

ILOM

INTEL-8001-EE

Memory Bad Parity

CASE

2

 

 

 

22878

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8001_J5_X4_Diag

ILOM

INTEL-8001-J5

Memory Mirror Broken

CASE

2

 

 

 

22879

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8001_G2_X4_Diag

ILOM

INTEL-8001-G2

Spare memory error

CASE

2

 

 

 

22880

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8001_AQ_X4_Diag

ILOM

INTEL-8001-AQ

Multibit memory module errors

CASE

2

 

 

 

22881

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8001_94_X4_Diag

ILOM

INTEL-8001-94

Memory module correctable errors exceeding acceptable levels

CASE

2

 

 

 

22883

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8002_1Y_X4_Diag

ILOM

INTEL-8002-1Y

A Middle Level Cache ECC Uncorrectable Error

CASE

2

 

 

 

22884

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8002_2D_X4_Diag

ILOM

INTEL-8002-2D

A Last Level Cache ECC Uncorrectable Error

CASE

2

 

 

 

22885

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_1J_X4_Diag

ILOM

INTEL-8000-1J

An internal error has been encountered on this cpu.

CASE

2

 

 

 

22886

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_22_X4_Diag

ILOM

INTEL-8000-22

A level 0 cache on this cpu is faulty.

CASE

2

 

 

 

22887

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_3X_X4_Diag

ILOM

INTEL-8000-3X

A level 1 cache on this cpu is faulty

CASE

2

 

 

 

22888

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_44_X4_Diag

ILOM

INTEL-8000-44

A level 2 cache on this cpu is faulty.

CASE

2

 

 

 

22889

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_5R_X4_Diag

ILOM

INTEL-8000-5R

A cache on this cpu is faulty.

CASE

2

 

 

 

22890

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_6C_X4_Diag

ILOM

INTEL-8000-6C

A level 0 Data TLB on this cpu is faulty.

CASE

2

 

 

 

22891

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_7Q_X4_Diag

ILOM

INTEL-8000-7Q

A level 1 Data TLB on this cpu is faulty.

CASE

2

 

 

 

22892

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_8Y_X4_Diag

ILOM

INTEL-8000-8Y

A level 2 Data TLB on this cpu is faulty.

CASE

2

 

 

 

22893

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_93_X4_Diag

ILOM

INTEL-8000-93

A Data TLB on this cpu is faulty.

CASE

2

 

 

 

22894

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_AH_X4_Diag

ILOM

INTEL-8000-AH

A level 0 Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

22895

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_CD_X4_Diag

ILOM

INTEL-8000-CD

A level 1 Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

22896

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_DP_X4_Diag

ILOM

INTEL-8000-DP

A level 2 Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

22897

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_EA_X4_Diag

ILOM

INTEL-8000-EA

An Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

22898

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_FS_X4_Diag

ILOM

INTEL-8000-FS

A level 0 TLB on this cpu is faulty.

CASE

2

 

 

 

22899

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_G5_X4_Diag

ILOM

INTEL-8000-G5

A level 1 TLB on this cpu is faulty.

CASE

2

 

 

 

22900

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_HX_X4_Diag

ILOM

INTEL-8000-HX

A level 2 TLB on this cpu is faulty.

CASE

2

 

 

 

22901

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_J2_X4_Diag

ILOM

INTEL-8000-J2

A TLB on this cpu is faulty.

CASE

2

 

 

 

22902

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_KJ_X4_Diag

ILOM

INTEL-8000-KJ

A level 0 Data Cache on this cpu is faulty.

CASE

2

 

 

 

22903

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_LE_X4_Diag

ILOM

INTEL-8000-LE

A level 1 Data Cache on this cpu is faulty.

CASE

2

 

 

 

22904

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_MQ_X4_Diag

ILOM

INTEL-8000-MQ

A level 2 Data Cache on this cpu is faulty.

CASE

2

 

 

 

22905

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_NC_X4_Diag

ILOM

INTEL-8000-NC

A Data Cache on this cpu is faulty.

CASE

2

 

 

 

22906

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_PR_X4_Diag

ILOM

INTEL-8000-PR

A level 0 Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

22907

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_Q4_X4_Diag

ILOM

INTEL-8000-Q4

A level 1 Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

22908

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_RD_X4_Diag

ILOM

INTEL-8000-RD

A level 2 Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

22909

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8000_SH_X4_Diag

ILOM

INTEL-8000-SH

An Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

22910

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.DISK_8000_0X_X4_Diag

ILOM

DISK-8000-0X

Predictive Disk Failure Imminent

CASE

2

 

 

 

22911

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.DISK_8000_12_X4_Diag

ILOM

DISK-8000-12

Disk Temperature Exceeded Threshold

CASE

2

 

 

 

22912

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.DISK_8000_2J_X4_Diag

ILOM

DISK-8000-2J

Disk Self-Test Failure

CASE

2

 

 

 

22913

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.DISK_8000_3E_X4_Diag

ILOM

DISK-8000-3E

SCSI fault for device

CASE

2

 

 

 

22914

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.DISK_8000_4Q_X4_Diag

ILOM

DISK-8000-4Q

SCSI fault for media

CASE

2

 

 

 

27598

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_2Y_X4_Diag

ILOM

SPX86-8000-2Y

Fan Column Failure

CASE

2

 

 

 

27599

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_33_X4_Diag

ILOM

SPX86-8000-33

Probable chassis Fan or Power Supply Fan failure

CASE

3

 

 

 

27600

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_AE_X4_Diag

ILOM

SPX86-8000-AE

Cache fault on Processor

CASE

2

 

 

 

27601

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_CJ_X4_Diag

ILOM

SPX86-8000-CJ

Data Cache Fault on Processor

CASE

2

 

 

 

27602

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_DC_X4_Diag

ILOM

SPX86-8000-DC

Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

27603

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_EQ_X4_Diag

ILOM

SPX86-8000-EQ

Instruction Cache Fault on Processor

CASE

2

 

 

 

27604

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_F4_X4_Diag

ILOM

SPX86-8000-F4

Internal Processor Fault

CASE

2

 

 

 

27605

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_GR_X4_Diag

ILOM

SPX86-8000-GR

Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

27606

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_H3_X4_Diag

ILOM

SPX86-8000-H3

Level 0 Cache Fault on Processor

CASE

2

 

 

 

27607

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_JY_X4_Diag

ILOM

SPX86-8000-JY

Level 0 Data Cache Fault on Processor

CASE

2

 

 

 

27608

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_KD_X4_Diag

ILOM

SPX86-8000-KD

Level 0 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

27609

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_LH_X4_Diag

ILOM

SPX86-8000-LH

Level 0 Instruction Cache Fault on Processor

CASE

2

 

 

 

27610

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_MA_X4_Diag

ILOM

SPX86-8000-MA

Level 0 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

27611

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_NP_X4_Diag

ILOM

SPX86-8000-NP

Level 0 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

27612

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_P5_X4_Diag

ILOM

SPX86-8000-P5

Level 1 Cache Fault on Processor

CASE

2

 

 

 

27613

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_QS_X4_Diag

ILOM

SPX86-8000-QS

Level 1 Data Cache Fault on Processor

CASE

2

 

 

 

27614

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_RJ_X4_Diag

ILOM

SPX86-8000-RJ

Level 1 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

27615

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_SE_X4_Diag

ILOM

SPX86-8000-SE

Level 1 Instruction Cache Fault on Processor

CASE

2

 

 

 

27616

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_TX_X4_Diag

ILOM

SPX86-8000-TX

Level 1 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

27617

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_U2_X4_Diag

ILOM

SPX86-8000-U2

Level 1 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

27618

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_VR_X4_Diag

ILOM

SPX86-8000-VR

Level 2 Cache Fault on Processor

CASE

2

 

 

 

27619

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_W4_X4_Diag

ILOM

SPX86-8000-W4

Level 2 Data Cache Fault on Processor

CASE

2

 

 

 

27620

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_XQ_X4_Diag

ILOM

SPX86-8000-XQ

Level 2 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

27621

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8000_YC_X4_Diag

ILOM

SPX86-8000-YC

Level 2 Instruction Cache Fault on Processor

CASE

2

 

 

 

27622

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8001_0Q_X4_Diag

ILOM

SPX86-8001-0Q

Level 2 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

27623

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8001_1C_X4_Diag

ILOM

SPX86-8001-1C

Level 2 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

27624

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8001_2R_X4_Diag

ILOM

SPX86-8001-2R

Memory Controller fault

CASE

2

 

 

 

27625

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8001_34_X4_Diag

ILOM

SPX86-8001-34

Initialization failure of the Intel Quickpath Interconnect Physical Layer, Link Layer, or Protocol Layer

CASE

2

 

 

 

27626

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8001_4X_X4_Diag

ILOM

SPX86-8001-4X

Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

27627

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8001_ME_X4_Diag

ILOM

SPX86-8001-ME

Reviewed 10/28/2011 – Event does not indicate that a part has failed. Added to SAMS reporting for further tracking. Message ID: SPX86-8001-ME indicates that the ILOM fault manager has received an error report indicating that memory DIMM's are not popula

CASE

2

 

 

 

27628

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8001_QX_X4_Diag

ILOM

SPX86-8001-QX

Memory DIMM Temperature Sensor Failed

CASE

2

 

 

 

27629

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8001_TS_X4_Diag

ILOM

SPX86-8001-TS

Memory DIMM Failure During Training

CASE

2

 

 

 

27630

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8001_U5_X4_Diag

ILOM

SPX86-8001-U5

Memory Uncorrectable ECC Fault

CASE

2

 

 

 

27632

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8002_2J_X4_Diag

ILOM

SPX86-8002-2J

Power to server not available

CASE

2

 

 

 

27636

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8002_A3_X4_Diag

ILOM

SPX86-8002-A3

Potentiometers not responding.

CASE

2

 

 

 

27639

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8002_Y5_X4_Diag

ILOM

SPX86-8002-Y5

Power Supply Internal Failure

CASE

2

 

 

 

27640

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_3A_X4_Diag

ILOM

SPX86-8003-3A

Fan Column Failure

CASE

2

 

 

 

27643

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_9Q_X4_Diag

ILOM

SPX86-8003-9Q

Component temp exceeded

CASE

2

 

 

 

27644

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_CR_X4_Diag

ILOM

SPX86-8003-CR

Home Agent error

CASE

2

 

 

 

27645

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_D2_X4_Diag

ILOM

SPX86-8003-D2

Intel QPI Link is Slow

CASE

2

 

 

 

27646

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_EX_X4_Diag

ILOM

SPX86-8003-EX

Intel QPI Link Training Failure

CASE

2

 

 

 

27647

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_FE_X4_Diag

ILOM

SPX86-8003-FE

Memory Controller Uncorrectable Error

CASE

2

 

 

 

27648

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_GJ_X4_Diag

ILOM

SPX86-8003-GJ

Memory Scrubbing UE

CASE

2

 

 

 

27649

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_HA_X4_Diag

ILOM

SPX86-8003-HA

Unknown Error from QPI Reference Code

CASE

2

 

 

 

27650

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_K5_X4_Diag

ILOM

SPX86-8003-K5

Intel Thermtrip Failure

CASE

2

 

 

 

27651

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_LS_X4_Diag

ILOM

SPX86-8003-LS

IIO core fatal fault

CASE

2

 

 

 

27652

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_M3_X4_Diag

ILOM

SPX86-8003-M3

IIO IRP Fatal Error

CASE

2

 

 

 

27653

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_NY_X4_Diag

ILOM

SPX86-8003-NY

IIO Miscellaneous Fatal Error

CASE

2

 

 

 

27655

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_QH_X4_Diag

ILOM

SPX86-8003-QH

IIO PCIE fault in downstream devices

CASE

2

 

 

 

27656

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_RR_X4_Diag

ILOM

SPX86-8003-RR

IIO PCIE Fatal Error

CASE

2

 

 

 

27657

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_S4_X4_Diag

ILOM

SPX86-8003-S4

IIO PCIE Error in Downstream Leaf Devices

CASE

2

 

 

 

27658

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_TQ_X4_Diag

ILOM

SPX86-8003-TQ

IIO PCIE Error in Root Port Device

CASE

2

 

 

 

27659

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_UC_X4_Diag

ILOM

SPX86-8003-UC

IIO VT-d Fatal Error

CASE

2

 

 

 

27660

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_0D_X4_Diag

ILOM

SPX86-8004-0D

DIMM disabled due to memtest errors

CASE

2

 

 

 

27661

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_1H_X4_Diag

ILOM

SPX86-8004-1H

Dimm Failed Memtest

CASE

2

 

 

 

27662

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_6A_X4_Diag

ILOM

SPX86-8004-6A

DIMM can't run at speeds required by platform

CASE

2

 

 

 

27663

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_7P_X4_Diag

ILOM

SPX86-8004-7P

Throttling not sufficient for this DIMM

CASE

2

 

 

 

27664

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_8X_X4_Diag

ILOM

SPX86-8004-8X

Single Symbol error Found in DIMM Training

CASE

2

 

 

 

27665

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_AJ_X4_Diag

ILOM

SPX86-8004-AJ

Unknown Error from Intel Memory Reference Code

CASE

2

 

 

 

27666

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_CE_X4_Diag

ILOM

SPX86-8004-CE

Fault due to excessive memory correctable errors

CASE

2

 

 

 

27667

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_DQ_X4_Diag

ILOM

SPX86-8004-DQ

BIOS Hangs due to Intel ME Failure

CASE

2

 

 

 

27668

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_EC_X4_Diag

ILOM

SPX86-8004-EC

Catastrophic Error Events

CASE

2

 

 

 

27669

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_FR_X4_Diag

ILOM

SPX86-8004-FR

Persistent Catastrophic Error

CASE

2

 

 

 

27670

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_G4_X4_Diag

ILOM

SPX86-8004-G4

Failure of Power Source

CASE

2

 

 

 

27675

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_MP_X4_Diag

ILOM

SPX86-8004-MP

A serial peripheral interface error (SPI) during a BIOS update or UEFI config backup/restore operation has occurred.\" The server will be unable to power on

CASE

2

 

 

 

27676

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_NA_X4_Diag

ILOM

SPX86-8004-NA

A firmware or hardware error with the power control unit (PCU) of a CPU has occurred Fatal machine check error will result in a system reset or power off

CASE

2

 

 

 

27677

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_PS_X4_Diag

ILOM

SPX86-8004-PS

A memory DIMM failure occurred during initialization

CASE

2

 

 

 

27681

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_T2_X4_Diag

ILOM

SPX86-8004-T2

A CPU timeout has occurred. System will panic and reset.

CASE

2

 

 

 

27682

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.ILOM_8000_30_X4_Diag

ILOM

ILOM-8000-30

Corrupt TLI

CASE

2

 

 

 

27683

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.ILOM_8000_2V_X4_Diag

ILOM

ILOM-8000-2V

Corrupt FRUID

CASE

2

 

 

 

27684

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8001_EE_X4_Diag

ILOM

INTEL-8001-EE

Memory Bad Parity

CASE

2

 

 

 

27685

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8001_J5_X4_Diag

ILOM

INTEL-8001-J5

Memory Mirror Broken

CASE

2

 

 

 

27686

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8001_G2_X4_Diag

ILOM

INTEL-8001-G2

Spare memory error

CASE

2

 

 

 

27687

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8001_AQ_X4_Diag

ILOM

INTEL-8001-AQ

Multibit memory module errors

CASE

2

 

 

 

27688

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8001_94_X4_Diag

ILOM

INTEL-8001-94

Memory module correctable errors exceeding acceptable levels

CASE

2

 

 

 

27690

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8002_1Y_X4_Diag

ILOM

INTEL-8002-1Y

A Middle Level Cache ECC Uncorrectable Error

CASE

2

 

 

 

27691

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8002_2D_X4_Diag

ILOM

INTEL-8002-2D

A Last Level Cache ECC Uncorrectable Error

CASE

2

 

 

 

27692

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_1J_X4_Diag

ILOM

INTEL-8000-1J

An internal error has been encountered on this cpu.

CASE

2

 

 

 

27693

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_22_X4_Diag

ILOM

INTEL-8000-22

A level 0 cache on this cpu is faulty.

CASE

2

 

 

 

27694

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_3X_X4_Diag

ILOM

INTEL-8000-3X

A level 1 cache on this cpu is faulty

CASE

2

 

 

 

27695

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_44_X4_Diag

ILOM

INTEL-8000-44

A level 2 cache on this cpu is faulty.

CASE

2

 

 

 

27696

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_5R_X4_Diag

ILOM

INTEL-8000-5R

A cache on this cpu is faulty.

CASE

2

 

 

 

27697

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_6C_X4_Diag

ILOM

INTEL-8000-6C

A level 0 Data TLB on this cpu is faulty.

CASE

2

 

 

 

27698

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_7Q_X4_Diag

ILOM

INTEL-8000-7Q

A level 1 Data TLB on this cpu is faulty.

CASE

2

 

 

 

27699

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_8Y_X4_Diag

ILOM

INTEL-8000-8Y

A level 2 Data TLB on this cpu is faulty.

CASE

2

 

 

 

27700

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_93_X4_Diag

ILOM

INTEL-8000-93

A Data TLB on this cpu is faulty.

CASE

2

 

 

 

27701

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_AH_X4_Diag

ILOM

INTEL-8000-AH

A level 0 Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

27702

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_CD_X4_Diag

ILOM

INTEL-8000-CD

A level 1 Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

27703

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_DP_X4_Diag

ILOM

INTEL-8000-DP

A level 2 Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

27704

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_EA_X4_Diag

ILOM

INTEL-8000-EA

An Instruction TLB on this cpu is faulty.

CASE

2

 

 

 

27705

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_FS_X4_Diag

ILOM

INTEL-8000-FS

A level 0 TLB on this cpu is faulty.

CASE

2

 

 

 

27706

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_G5_X4_Diag

ILOM

INTEL-8000-G5

A level 1 TLB on this cpu is faulty.

CASE

2

 

 

 

27707

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_HX_X4_Diag

ILOM

INTEL-8000-HX

A level 2 TLB on this cpu is faulty.

CASE

2

 

 

 

27708

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_J2_X4_Diag

ILOM

INTEL-8000-J2

A TLB on this cpu is faulty.

CASE

2

 

 

 

27709

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_KJ_X4_Diag

ILOM

INTEL-8000-KJ

A level 0 Data Cache on this cpu is faulty.

CASE

2

 

 

 

27710

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_LE_X4_Diag

ILOM

INTEL-8000-LE

A level 1 Data Cache on this cpu is faulty.

CASE

2

 

 

 

27711

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_MQ_X4_Diag

ILOM

INTEL-8000-MQ

A level 2 Data Cache on this cpu is faulty.

CASE

2

 

 

 

27712

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_NC_X4_Diag

ILOM

INTEL-8000-NC

A Data Cache on this cpu is faulty.

CASE

2

 

 

 

27713

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_PR_X4_Diag

ILOM

INTEL-8000-PR

A level 0 Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

27714

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_Q4_X4_Diag

ILOM

INTEL-8000-Q4

A level 1 Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

27715

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_RD_X4_Diag

ILOM

INTEL-8000-RD

A level 2 Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

27716

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8000_SH_X4_Diag

ILOM

INTEL-8000-SH

An Instruction Cache on this cpu is faulty.

CASE

2

 

 

 

27717

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.DISK_8000_0X_X4_Diag

ILOM

DISK-8000-0X

Predictive Disk Failure Imminent

CASE

2

 

 

 

27718

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.DISK_8000_12_X4_Diag

ILOM

DISK-8000-12

Disk Temperature Exceeded Threshold

CASE

2

 

 

 

27719

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.DISK_8000_2J_X4_Diag

ILOM

DISK-8000-2J

Disk Self-Test Failure

CASE

2

 

 

 

27720

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.DISK_8000_3E_X4_Diag

ILOM

DISK-8000-3E

SCSI fault for device

CASE

2

 

 

 

27721

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.DISK_8000_4Q_X4_Diag

ILOM

DISK-8000-4Q

SCSI fault for media

CASE

2

 

 

 

49263

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_73_EXA_X4_Diag

ILOM

SPX86-8003-73

Lack of AC input power.

CASE

3

Modified

27-May-14

 

50857

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.PCIEX_8000_0A_EXA_X4_Diag

ILOM

PCIEX-8000-0A

A problem was detected for a PCIEX device.

CASE

2

New

08-Sep-14

 

50858

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.PCIEX_8000_3S_EXA_X4_Diag

ILOM

PCIEX-8000-3S

A problem has been detected on one of the specified devices or connecting buses.

CASE

2

New

08-Sep-14

 

50859

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.PCIEX_8000_8R_EXA_X4_Diag

ILOM

PCIEX-8000-8R

The transmitting device sent an invalid request.

CASE

2

New

08-Sep-14

 

50860

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.PCIEX_8000_DJ_EXA_X4_Diag

ILOM

PCIEX-8000-DJ

A problem has been detected on one of the specified devices or connecting buses.

CASE

2

New

08-Sep-14

 

50861

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.PCIEX_8000_J5_EXA_X4_Diag

ILOM

PCIEX-8000-J5

Too many recovered internal errors have been detected within the specified PCIEX device.

CASE

2

New

08-Sep-14

 

50862

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.PCIEX_8000_KP_EXA_X4_Diag

ILOM

PCIEX-8000-KP

Too many recovered bus errors have been detected.

CASE

2

New

08-Sep-14

 

50863

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.PCIEX_8000_MH_EXA_X4_Diag

ILOM

PCIEX-8000-MH

Too many recovered errors have been detected, which indicates a problem with the specified device.

CASE

2

New

08-Sep-14

 

50864

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.PCIEX_8000_SQ_EXA_X4_Diag

ILOM

PCIEX-8000-SQ

An uncorrectable error was detected in the PCIe Root Complex.

CASE

2

New

08-Sep-14

 

50865

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.PCIEX_8000_V2_EXA_X4_Diag

ILOM

PCIEX-8000-V2

A decrease in PCIe link bandwidth has been detected.

CASE

2

New

08-Sep-14

 

50866

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.PCIEX_8000_YJ_EXA_X4_Diag

ILOM

PCIEX-8000-YJ

Too many recovered bus errors have been detected.

CASE

2

New

08-Sep-14

 

14563

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.INTEL_8002_03_EXA_X4_Diag

ILOM

INTEL-8002-03

Uncorrectable SW recoverable memory scrubbing error

DRAFT

3

 

 

 

22882

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.INTEL_8002_03_X4_Diag

ILOM

INTEL-8002-03

Uncorrectable SW recoverable memory scrubbing error

DRAFT

3

 

 

 

27689

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.INTEL_8002_03_X4_Diag

ILOM

INTEL-8002-03

Uncorrectable SW recoverable memory scrubbing error

DRAFT

3

 

 

 

14508

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8001_XH_EXA_X4_Diag

ILOM

SPX86-8001-XH

Potential candidate for a draft SR

NO_CASE

 

 

 

 

14510

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8002_3E_EXA_X4_Diag

ILOM

SPX86-8002-3E

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

14511

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8002_4Q_EXA_X4_Diag

ILOM

SPX86-8002-4Q

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

14513

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8002_NR_EXA_X4_Diag

ILOM

SPX86-8002-NR

Dave to research - KA indicates that fault will usually be caused by insufficient power. Engineering has determined that this event will likely be caused by power budget configuration.

NO_CASE

 

 

 

 

14514

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8002_PC_EXA_X4_Diag

ILOM

SPX86-8002-PC

KA indicates that this event can be caused by shutdown. The fourth suggested action is to replace MB/Blade.

NO_CASE

 

 

 

 

14517

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8003_4H_EXA_X4_Diag

ILOM

SPX86-8003-4H

Power Supply unsupported

NO_CASE

 

 

 

 

14547

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_HY_EXA_X4_Diag

ILOM

SPX86-8004-HY

Config issue not actionable

NO_CASE

 

 

 

 

14548

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_J3_EXA_X4_Diag

ILOM

SPX86-8004-J3

Config issue not actionable

NO_CASE

 

 

 

 

14549

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_KH_EXA_X4_Diag

ILOM

SPX86-8004-KH

Config issue not actionable

NO_CASE

 

 

 

 

14550

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_LD_EXA_X4_Diag

ILOM

SPX86-8004-LD

FW corrupt not actionable

NO_CASE

 

 

 

 

14554

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_Q5_EXA_X4_Diag

ILOM

SPX86-8004-Q5

One or more non-ECC DIMMs installed are not supported. Config issue

NO_CASE

 

 

 

 

14555

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_RE_EXA_X4_Diag

ILOM

SPX86-8004-RE

One or more DIMMs installed have extended addressing capabilities that are not supported by the processor. Config issue

NO_CASE

 

 

 

 

14556

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMDiagnosis.SPX86_8004_SJ_EXA_X4_Diag

ILOM

SPX86-8004-SJ

System has DIMMs with incompatible memory types. Config issue

NO_CASE

 

 

 

 

14596

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_2Y

ILOM

SPX86-8000-2Y

Fan Column Failure

NO_CASE

 

 

 

 

14597

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_33

ILOM

SPX86-8000-33

Fan speed is below normal range

NO_CASE

 

 

 

 

14598

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_AE

ILOM

SPX86-8000-AE

Cache fault on Processor

NO_CASE

 

 

 

 

14599

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_CJ

ILOM

SPX86-8000-CJ

Data Cache Fault on Processor

NO_CASE

 

 

 

 

14600

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_DC

ILOM

SPX86-8000-DC

Data Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

14601

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_EQ

ILOM

SPX86-8000-EQ

Instruction Cache Fault on Processor

NO_CASE

 

 

 

 

14602

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_F4

ILOM

SPX86-8000-F4

Internal Processor Fault

NO_CASE

 

 

 

 

14603

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_GR

ILOM

SPX86-8000-GR

Instruction Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

14604

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_H3

ILOM

SPX86-8000-H3

Level 0 Cache Fault on Processor

NO_CASE

 

 

 

 

14605

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_JY

ILOM

SPX86-8000-JY

Level 0 Data Cache Fault on Processor

NO_CASE

 

 

 

 

14606

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_KD

ILOM

SPX86-8000-KD

Level 0 Data Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

14607

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_LH

ILOM

SPX86-8000-LH

Level 0 Instruction Cache Fault on Processor

NO_CASE

 

 

 

 

14608

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_MA

ILOM

SPX86-8000-MA

Level 0 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

14609

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_NP

ILOM

SPX86-8000-NP

Level 0 Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

14610

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_P5

ILOM

SPX86-8000-P5

Level 1 Cache Fault on Processor

NO_CASE

 

 

 

 

14611

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_QS

ILOM

SPX86-8000-QS

Level 1 Data Cache Fault on Processor

NO_CASE

 

 

 

 

14612

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_RJ

ILOM

SPX86-8000-RJ

Level 1 Data Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

14613

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_SE

ILOM

SPX86-8000-SE

Level 1 Instruction Cache Fault on Processor

NO_CASE

 

 

 

 

14614

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_TX

ILOM

SPX86-8000-TX

Level 1 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

14615

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_U2

ILOM

SPX86-8000-U2

Level 1 Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

14616

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_VR

ILOM

SPX86-8000-VR

Level 2 Cache Fault on Processor

NO_CASE

 

 

 

 

14617

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_W4

ILOM

SPX86-8000-W4

Level 2 Data Cache Fault on Processor

NO_CASE

 

 

 

 

14618

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_XQ

ILOM

SPX86-8000-XQ

Level 2 Data Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

14619

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8000_YC

ILOM

SPX86-8000-YC

Level 2 Instruction Cache Fault on Processor

NO_CASE

 

 

 

 

14620

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8001_0Q

ILOM

SPX86-8001-0Q

Level 2 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

14621

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8001_1C

ILOM

SPX86-8001-1C

Level 2 Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

14622

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8001_2R

ILOM

SPX86-8001-2R

Memory Controller fault

NO_CASE

 

 

 

 

14623

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8001_34

ILOM

SPX86-8001-34

Initialization failure of the Intel Quickpath Interconnect Physical Layer, Link Layer, or Protocol Layer

NO_CASE

 

 

 

 

14624

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8001_4X

ILOM

SPX86-8001-4X

Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

14625

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8001_ME

ILOM

SPX86-8001-ME

Reviewed 10/28/2011 – Event does not indicate that a part has failed. Added to SAMS reporting for further tracking.

NO_CASE

 

 

 

 

14626

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8001_QX

ILOM

SPX86-8001-QX

Memory DIMM Temperature Sensor Failed

NO_CASE

 

 

 

 

14627

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8001_TS

ILOM

SPX86-8001-TS

Memory DIMM Failure During Training

NO_CASE

 

 

 

 

14628

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8001_U5

ILOM

SPX86-8001-U5

Memory Uncorrectable ECC Fault

NO_CASE

 

 

 

 

14629

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8001_XH

ILOM

SPX86-8001-XH

Potential candidate for a draft SR

NO_CASE

 

 

 

 

14630

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8002_2J

ILOM

SPX86-8002-2J

Power to server not available

NO_CASE

 

 

 

 

14631

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8002_3E

ILOM

SPX86-8002-3E

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

14632

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8002_4Q

ILOM

SPX86-8002-4Q

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

14633

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8002_A3

ILOM

SPX86-8002-A3

Potentiometers not responding.

NO_CASE

 

 

 

 

14634

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8002_NR

ILOM

SPX86-8002-NR

Dave to research - KA indicates that fault will usually be caused by insufficient power. Engineering has determined that this event will likely be caused by power budget configuration.

NO_CASE

 

 

 

 

14635

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8002_PC

ILOM

SPX86-8002-PC

KA indicates that this event can be caused by shutdown. The fourth suggested action is to replace MB/Blade.

NO_CASE

 

 

 

 

14636

ODA-X4-2

Exadata.ILOM_Alarms___X4.ILOMfdd.SPX86_8003_73

ILOM

SPX86-8003-73

Lack of AC input power.

NO_CASE

 

 

 

 

22827

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_XH_X4_Diag

ILOM

SPX86-8001-XH

Potential candidate for a draft SR

NO_CASE

 

 

 

 

22829

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_3E_X4_Diag

ILOM

SPX86-8002-3E

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

22830

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_4Q_X4_Diag

ILOM

SPX86-8002-4Q

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

22832

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_NR_X4_Diag

ILOM

SPX86-8002-NR

Dave to research - KA indicates that fault will usually be caused by insufficient power. Engineering has determined that this event will likely be caused by power budget configuration.

NO_CASE

 

 

 

 

22833

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_PC_X4_Diag

ILOM

SPX86-8002-PC

KA indicates that this event can be caused by shutdown. The fourth suggested action is to replace MB/Blade.

NO_CASE

 

 

 

 

22836

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_4H_X4_Diag

ILOM

SPX86-8003-4H

Power Supply unsupported

NO_CASE

 

 

 

 

22837

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_73_X4_Diag

ILOM

SPX86-8003-73

Lack of AC input power.

NO_CASE

 

 

 

 

22866

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_HY_X4_Diag

ILOM

SPX86-8004-HY

Config issue not actionable

NO_CASE

 

 

 

 

22867

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_J3_X4_Diag

ILOM

SPX86-8004-J3

Config issue not actionable

NO_CASE

 

 

 

 

22868

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_KH_X4_Diag

ILOM

SPX86-8004-KH

Config issue not actionable

NO_CASE

 

 

 

 

22869

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_LD_X4_Diag

ILOM

SPX86-8004-LD

FW corrupt not actionable

NO_CASE

 

 

 

 

22873

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_Q5_X4_Diag

ILOM

SPX86-8004-Q5

One or more non-ECC DIMMs installed are not supported. Config issue

NO_CASE

 

 

 

 

22874

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_RE_X4_Diag

ILOM

SPX86-8004-RE

One or more DIMMs installed have extended addressing capabilities that are not supported by the processor. Config issue

NO_CASE

 

 

 

 

22875

ODA-X4-2

X4_2x.ILOM_alarms.ILOMDiagnosis.SPX86_8004_SJ_X4_Diag

ILOM

SPX86-8004-SJ

System has DIMMs with incompatible memory types. Config issue

NO_CASE

 

 

 

 

22915

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_2Y

ILOM

SPX86-8000-2Y

Fan Column Failure

NO_CASE

 

 

 

 

22916

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_33

ILOM

SPX86-8000-33

Fan speed is below normal range

NO_CASE

 

 

 

 

22917

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_AE

ILOM

SPX86-8000-AE

Cache fault on Processor

NO_CASE

 

 

 

 

22918

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_CJ

ILOM

SPX86-8000-CJ

Data Cache Fault on Processor

NO_CASE

 

 

 

 

22919

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_DC

ILOM

SPX86-8000-DC

Data Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

22920

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_EQ

ILOM

SPX86-8000-EQ

Instruction Cache Fault on Processor

NO_CASE

 

 

 

 

22921

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_F4

ILOM

SPX86-8000-F4

Internal Processor Fault

NO_CASE

 

 

 

 

22922

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_GR

ILOM

SPX86-8000-GR

Instruction Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

22923

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_H3

ILOM

SPX86-8000-H3

Level 0 Cache Fault on Processor

NO_CASE

 

 

 

 

22924

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_JY

ILOM

SPX86-8000-JY

Level 0 Data Cache Fault on Processor

NO_CASE

 

 

 

 

22925

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_KD

ILOM

SPX86-8000-KD

Level 0 Data Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

22926

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_LH

ILOM

SPX86-8000-LH

Level 0 Instruction Cache Fault on Processor

NO_CASE

 

 

 

 

22927

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_MA

ILOM

SPX86-8000-MA

Level 0 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

22928

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_NP

ILOM

SPX86-8000-NP

Level 0 Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

22929

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_P5

ILOM

SPX86-8000-P5

Level 1 Cache Fault on Processor

NO_CASE

 

 

 

 

22930

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_QS

ILOM

SPX86-8000-QS

Level 1 Data Cache Fault on Processor

NO_CASE

 

 

 

 

22931

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_RJ

ILOM

SPX86-8000-RJ

Level 1 Data Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

22932

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_SE

ILOM

SPX86-8000-SE

Level 1 Instruction Cache Fault on Processor

NO_CASE

 

 

 

 

22933

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_TX

ILOM

SPX86-8000-TX

Level 1 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

22934

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_U2

ILOM

SPX86-8000-U2

Level 1 Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

22935

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_VR

ILOM

SPX86-8000-VR

Level 2 Cache Fault on Processor

NO_CASE

 

 

 

 

22936

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_W4

ILOM

SPX86-8000-W4

Level 2 Data Cache Fault on Processor

NO_CASE

 

 

 

 

22937

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_XQ

ILOM

SPX86-8000-XQ

Level 2 Data Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

22938

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8000_YC

ILOM

SPX86-8000-YC

Level 2 Instruction Cache Fault on Processor

NO_CASE

 

 

 

 

22939

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8001_0Q

ILOM

SPX86-8001-0Q

Level 2 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

22940

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8001_1C

ILOM

SPX86-8001-1C

Level 2 Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

22941

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8001_2R

ILOM

SPX86-8001-2R

Memory Controller fault

NO_CASE

 

 

 

 

22942

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8001_34

ILOM

SPX86-8001-34

Initialization failure of the Intel Quickpath Interconnect Physical Layer, Link Layer, or Protocol Layer

NO_CASE

 

 

 

 

22943

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8001_4X

ILOM

SPX86-8001-4X

Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

22944

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8001_ME

ILOM

SPX86-8001-ME

Reviewed 10/28/2011 – Event does not indicate that a part has failed. Added to SAMS reporting for further tracking.

NO_CASE

 

 

 

 

22945

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8001_QX

ILOM

SPX86-8001-QX

Memory DIMM Temperature Sensor Failed

NO_CASE

 

 

 

 

22946

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8001_TS

ILOM

SPX86-8001-TS

Memory DIMM Failure During Training

NO_CASE

 

 

 

 

22947

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8001_U5

ILOM

SPX86-8001-U5

Memory Uncorrectable ECC Fault

NO_CASE

 

 

 

 

22948

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8001_XH

ILOM

SPX86-8001-XH

Potential candidate for a draft SR

NO_CASE

 

 

 

 

22949

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8002_2J

ILOM

SPX86-8002-2J

Power to server not available

NO_CASE

 

 

 

 

22950

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8002_3E

ILOM

SPX86-8002-3E

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

22951

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8002_4Q

ILOM

SPX86-8002-4Q

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

22952

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8002_A3

ILOM

SPX86-8002-A3

Potentiometers not responding.

NO_CASE

 

 

 

 

22953

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8002_NR

ILOM

SPX86-8002-NR

Dave to research - KA indicates that fault will usually be caused by insufficient power. Engineering has determined that this event will likely be caused by power budget configuration.

NO_CASE

 

 

 

 

22954

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8002_PC

ILOM

SPX86-8002-PC

KA indicates that this event can be caused by shutdown. The fourth suggested action is to replace MB/Blade.

NO_CASE

 

 

 

 

22955

ODA-X4-2

X4_2x.ILOM_alarms.ILOMfdd.SPX86_8003_73

ILOM

SPX86-8003-73

Lack of AC input power.

NO_CASE

 

 

 

 

27631

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8001_XH_X4_Diag

ILOM

SPX86-8001-XH

Potential candidate for a draft SR

NO_CASE

 

 

 

 

27633

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8002_3E_X4_Diag

ILOM

SPX86-8002-3E

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

27634

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8002_4Q_X4_Diag

ILOM

SPX86-8002-4Q

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

27635

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8002_5C_1_X4

ILOM

SPX86-8002-5C

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

27637

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8002_NR_X4_Diag

ILOM

SPX86-8002-NR

Dave to research - KA indicates that fault will usually be caused by insufficient power. Engineering has determined that this event will likely be caused by power budget configuration.

NO_CASE

 

 

 

 

27638

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8002_PC_X4_Diag

ILOM

SPX86-8002-PC

KA indicates that this event can be caused by shutdown. The fourth suggested action is to replace MB/Blade.

NO_CASE

 

 

 

 

27641

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_4H_X4_Diag

ILOM

SPX86-8003-4H

Power Supply unsupported

NO_CASE

 

 

 

 

27642

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8003_73_X4_Diag

ILOM

SPX86-8003-73

Lack of AC input power.

NO_CASE

 

 

 

 

27671

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_HY_X4_Diag

ILOM

SPX86-8004-HY

Config issue not actionable

NO_CASE

 

 

 

 

27672

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_J3_X4_Diag

ILOM

SPX86-8004-J3

Config issue not actionable

NO_CASE

 

 

 

 

27673

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_KH_X4_Diag

ILOM

SPX86-8004-KH

Config issue not actionable

NO_CASE

 

 

 

 

27674

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_LD_X4_Diag

ILOM

SPX86-8004-LD

FW corrupt not actionable

NO_CASE

 

 

 

 

27678

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_Q5_X4_Diag

ILOM

SPX86-8004-Q5

One or more non-ECC DIMMs installed are not supported. Config issue

NO_CASE

 

 

 

 

27679

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_RE_X4_Diag

ILOM

SPX86-8004-RE

One or more DIMMs installed have extended addressing capabilities that are not supported by the processor. Config issue

NO_CASE

 

 

 

 

27680

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMDiagnosis.SPX86_8004_SJ_X4_Diag

ILOM

SPX86-8004-SJ

System has DIMMs with incompatible memory types. Config issue

NO_CASE

 

 

 

 

27722

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_2Y

ILOM

SPX86-8000-2Y

Fan Column Failure

NO_CASE

 

 

 

 

27723

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_33

ILOM

SPX86-8000-33

Fan speed is below normal range

NO_CASE

 

 

 

 

27724

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_AE

ILOM

SPX86-8000-AE

Cache fault on Processor

NO_CASE

 

 

 

 

27725

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_CJ

ILOM

SPX86-8000-CJ

Data Cache Fault on Processor

NO_CASE

 

 

 

 

27726

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_DC

ILOM

SPX86-8000-DC

Data Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

27727

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_EQ

ILOM

SPX86-8000-EQ

Instruction Cache Fault on Processor

NO_CASE

 

 

 

 

27728

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_F4

ILOM

SPX86-8000-F4

Internal Processor Fault

NO_CASE

 

 

 

 

27729

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_GR

ILOM

SPX86-8000-GR

Instruction Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

27730

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_H3

ILOM

SPX86-8000-H3

Level 0 Cache Fault on Processor

NO_CASE

 

 

 

 

27731

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_JY

ILOM

SPX86-8000-JY

Level 0 Data Cache Fault on Processor

NO_CASE

 

 

 

 

27732

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_KD

ILOM

SPX86-8000-KD

Level 0 Data Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

27733

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_LH

ILOM

SPX86-8000-LH

Level 0 Instruction Cache Fault on Processor

NO_CASE

 

 

 

 

27734

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_MA

ILOM

SPX86-8000-MA

Level 0 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

27735

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_NP

ILOM

SPX86-8000-NP

Level 0 Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

27736

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_P5

ILOM

SPX86-8000-P5

Level 1 Cache Fault on Processor

NO_CASE

 

 

 

 

27737

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_QS

ILOM

SPX86-8000-QS

Level 1 Data Cache Fault on Processor

NO_CASE

 

 

 

 

27738

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_RJ

ILOM

SPX86-8000-RJ

Level 1 Data Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

27739

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_SE

ILOM

SPX86-8000-SE

Level 1 Instruction Cache Fault on Processor

NO_CASE

 

 

 

 

27740

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_TX

ILOM

SPX86-8000-TX

Level 1 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

27741

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_U2

ILOM

SPX86-8000-U2

Level 1 Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

27742

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_VR

ILOM

SPX86-8000-VR

Level 2 Cache Fault on Processor

NO_CASE

 

 

 

 

27743

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_W4

ILOM

SPX86-8000-W4

Level 2 Data Cache Fault on Processor

NO_CASE

 

 

 

 

27744

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_XQ

ILOM

SPX86-8000-XQ

Level 2 Data Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

27745

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8000_YC

ILOM

SPX86-8000-YC

Level 2 Instruction Cache Fault on Processor

NO_CASE

 

 

 

 

27746

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8001_0Q

ILOM

SPX86-8001-0Q

Level 2 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

27747

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8001_1C

ILOM

SPX86-8001-1C

Level 2 Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

27748

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8001_2R

ILOM

SPX86-8001-2R

Memory Controller fault

NO_CASE

 

 

 

 

27749

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8001_34

ILOM

SPX86-8001-34

Initialization failure of the Intel Quickpath Interconnect Physical Layer, Link Layer, or Protocol Layer

NO_CASE

 

 

 

 

27750

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8001_4X

ILOM

SPX86-8001-4X

Translation Lookaside Buffer (TLB) Fault on Processor

NO_CASE

 

 

 

 

27751

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8001_ME

ILOM

SPX86-8001-ME

Reviewed 10/28/2011 – Event does not indicate that a part has failed. Added to SAMS reporting for further tracking.

NO_CASE

 

 

 

 

27752

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8001_QX

ILOM

SPX86-8001-QX

Memory DIMM Temperature Sensor Failed

NO_CASE

 

 

 

 

27753

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8001_TS

ILOM

SPX86-8001-TS

Memory DIMM Failure During Training

NO_CASE

 

 

 

 

27754

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8001_U5

ILOM

SPX86-8001-U5

Memory Uncorrectable ECC Fault

NO_CASE

 

 

 

 

27755

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8001_XH

ILOM

SPX86-8001-XH

Potential candidate for a draft SR

NO_CASE

 

 

 

 

27756

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8002_2J

ILOM

SPX86-8002-2J

Power to server not available

NO_CASE

 

 

 

 

27757

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8002_3E

ILOM

SPX86-8002-3E

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

27758

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8002_4Q

ILOM

SPX86-8002-4Q

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

27759

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8002_A3

ILOM

SPX86-8002-A3

Potentiometers not responding.

NO_CASE

 

 

 

 

27760

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8002_NR

ILOM

SPX86-8002-NR

Dave to research - KA indicates that fault will usually be caused by insufficient power. Engineering has determined that this event will likely be caused by power budget configuration.

NO_CASE

 

 

 

 

27761

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8002_PC

ILOM

SPX86-8002-PC

KA indicates that this event can be caused by shutdown. The fourth suggested action is to replace MB/Blade.

NO_CASE

 

 

 

 

27762

ODA-X4-2

X4_Xx.ILOM_alarms.ILOMfdd.SPX86_8003_73

ILOM

SPX86-8003-73

Lack of AC input power.

NO_CASE

 

 

 

 

27845

ODA-X4-2

X4_Xx.FMA_alarms.ILOMDiagnosis.SPX86_8003_73_1_X4

ILOM

SPX86-8003-73

Lack of AC input power.

NO_CASE

 

 

 

 


X4370 M2

Rule ID

Product

Rule Name

Source

Knowledge Link

Description

Action

Severity

History

Last Update Date

Reason

14125

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_33_1_EXA

ILOM

SPX86-8000-33

Probable chassis Fan or Power Supply Fan failure

CASE

3

 

 

 

14128

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_82_1_EXA

ILOM

SPX86-8000-82

Power Supply Over Current Fault

CASE

2

 

 

 

14129

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_9X_1_EXA

ILOM

SPX86-8000-9X

Power Supply Over-temperature Failure

CASE

2

 

 

 

14130

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_AE_1_EXA

ILOM

SPX86-8000-AE

Cache fault on Processor

CASE

2

 

 

 

14131

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_CJ_1_EXA

ILOM

SPX86-8000-CJ

Data Cache Fault on Processor

CASE

2

 

 

 

14132

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_DC_1_EXA

ILOM

SPX86-8000-DC

Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14133

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_EQ_1_EXA

ILOM

SPX86-8000-EQ

Instruction Cache Fault on Processor

CASE

2

 

 

 

14134

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_F4_1_EXA

ILOM

SPX86-8000-F4

Internal Processor Fault

CASE

2

 

 

 

14135

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_GR_1_EXA

ILOM

SPX86-8000-GR

Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14136

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_H3_1_EXA

ILOM

SPX86-8000-H3

Level 0 Cache Fault on Processor

CASE

2

 

 

 

14137

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_JY_1_EXA

ILOM

SPX86-8000-JY

Level 0 Data Cache Fault on Processor

CASE

2

 

 

 

14138

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_KD_1_EXA

ILOM

SPX86-8000-KD

Level 0 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14139

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_LH_1_EXA

ILOM

SPX86-8000-LH

Level 0 Instruction Cache Fault on Processor

CASE

2

 

 

 

14140

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_MA_1_EXA

ILOM

SPX86-8000-MA

Level 0 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14141

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_NP_1_EXA

ILOM

SPX86-8000-NP

Level 0 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14142

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_P5_1_EXA

ILOM

SPX86-8000-P5

Level 1 Cache Fault on Processor

CASE

2

 

 

 

14143

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_QS_1_EXA

ILOM

SPX86-8000-QS

Level 1 Data Cache Fault on Processor

CASE

2

 

 

 

14144

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_RJ_1_EXA

ILOM

SPX86-8000-RJ

Level 1 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14145

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_SE_1_EXA

ILOM

SPX86-8000-SE

Level 1 Instruction Cache Fault on Processor

CASE

2

 

 

 

14146

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_TX_1_EXA

ILOM

SPX86-8000-TX

Level 1 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14147

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_U2_1_EXA

ILOM

SPX86-8000-U2

Level 1 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14148

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_VR_1_EXA

ILOM

SPX86-8000-VR

Level 2 Cache Fault on Processor

CASE

2

 

 

 

14149

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_W4_1_EXA

ILOM

SPX86-8000-W4

Level 2 Data Cache Fault on Processor

CASE

2

 

 

 

14150

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_XQ_1_EXA

ILOM

SPX86-8000-XQ

Level 2 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14151

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_YC_1_EXA

ILOM

SPX86-8000-YC

Level 2 Instruction Cache Fault on Processor

CASE

2

 

 

 

14152

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_0Q_1_EXA

ILOM

SPX86-8001-0Q

Level 2 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14153

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_1C_1_EXA

ILOM

SPX86-8001-1C

Level 2 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14154

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_2R_1_EXA

ILOM

SPX86-8001-2R

Memory Controller fault

CASE

2

 

 

 

14155

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_34_1_EXA

ILOM

SPX86-8001-34

Initialization failure of the Intel Quickpath Interconnect Physical Layer, Link Layer, or Protocol Layer

CASE

2

 

 

 

14156

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_4X_1_EXA

ILOM

SPX86-8001-4X

Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

 

 

 

14157

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_52_1_EXA

ILOM

SPX86-8001-52

Intel 5500 Chipset Core Fault

CASE

2

 

 

 

14158

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_6J_1_EXA

ILOM

SPX86-8001-6J

Intel 5500 Chipset Fault

CASE

2

 

 

 

14159

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_7E_1_EXA

ILOM

SPX86-8001-7E

Intel 5500 Chipset ESI Internal Fault

CASE

2

 

 

 

14160

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_85_1_EXA

ILOM

SPX86-8001-85

Intel 5500 Chipset Exceeds Temperature Threshold

CASE

2

 

 

 

14161

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_9S_1_EXA

ILOM

SPX86-8001-9S

Fatal PCI-E Internal Fault

CASE

2

 

 

 

14162

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_AA_1_EXA

ILOM

SPX86-8001-AA

Non-Fatal PCI-E Internal Fault

CASE

2

 

 

 

14163

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_DD_1_EXA

ILOM

SPX86-8001-DD

Memory Channel Fault

CASE

2

 

 

 

14164

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_EH_1_EXA

ILOM

SPX86-8001-EH

Fatal Memory Test Failure

CASE

2

 

 

 

14165

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_H4_1_EXA

ILOM

SPX86-8001-H4

Memory Correctable ECC Fault

CASE

3

 

 

 

14166

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_ME_1_EXA

ILOM

SPX86-8001-ME

Reviewed 10/28/2011 – Event does not indicate that a part has failed. Added to SAMS reporting for further tracking. Message ID: SPX86-8001-ME indicates that the ILOM fault manager has received

CASE

2

 

 

 

14167

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_P2_1_EXA

ILOM

SPX86-8001-P2

Memory DIMM SPD Fault

CASE

2

 

 

 

14168

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_QX_1_EXA

ILOM

SPX86-8001-QX

Memory DIMM Temperature Sensor Failed

CASE

2

 

 

 

14170

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_SA_1_EXA

ILOM

SPX86-8001-SA

Memory DIMM Fault

CASE

2

 

 

 

14171

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_TS_1_EXA

ILOM

SPX86-8001-TS

Memory DIMM Failure During Training

CASE

2

 

 

 

14175

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_12_1_EXA

ILOM

SPX86-8002-12

On Die termination failed

CASE

2

 

 

 

14176

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_2J_1_EXA

ILOM

SPX86-8002-2J

Power to server not available

CASE

2

 

 

 

14182

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_A3_1_EXA

ILOM

SPX86-8002-A3

Potentiometers not responding.

CASE

2

 

 

 

14200

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8003_73_1_EXA

ILOM

SPX86-8003-73

Lack of AC input power.

CASE

3

 

 

 

23215

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_82_1

ILOM

SPX86-8000-82

Power Supply Over Current Fault

CASE

2

 

 

 

23216

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_9X_1

ILOM

SPX86-8000-9X

Power Supply Over-temperature Failure

CASE

2

 

 

 

23244

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_52_1

ILOM

SPX86-8001-52

Intel 5500 Chipset Core Fault

CASE

2

 

 

 

23245

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_6J_1

ILOM

SPX86-8001-6J

Intel 5500 Chipset Fault

CASE

2

 

 

 

23246

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_7E_1

ILOM

SPX86-8001-7E

Intel 5500 Chipset ESI Internal Fault

CASE

2

 

 

 

23247

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_85_1

ILOM

SPX86-8001-85

Intel 5500 Chipset Exceeds Temperature Threshold

CASE

2

 

 

 

23248

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_9S_1

ILOM

SPX86-8001-9S

Fatal PCI-E Internal Fault

CASE

2

 

 

 

23249

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_AA_1

ILOM

SPX86-8001-AA

Non-Fatal PCI-E Internal Fault

CASE

2

 

 

 

23250

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_DD_1

ILOM

SPX86-8001-DD

Memory Channel Fault

CASE

2

 

 

 

23251

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_EH_1

ILOM

SPX86-8001-EH

Fatal Memory Test Failure

CASE

2

 

 

 

23252

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_H4_1

ILOM

SPX86-8001-H4

Memory Correctable ECC Fault

CASE

3

 

 

 

23254

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_P2_1

ILOM

SPX86-8001-P2

Memory DIMM SPD Fault

CASE

2

 

 

 

23257

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_SA_1

ILOM

SPX86-8001-SA

Memory DIMM Fault

CASE

2

 

 

 

23262

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_12_1

ILOM

SPX86-8002-12

On Die termination failed

CASE

2

 

 

 

34519

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_U5_1_EXA

ILOM

SPX86-8001-U5

Memory Uncorrectable ECC Fault

CASE

2

 

06-Feb-14

 

48949

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_33_1

ILOM

SPX86-8000-33

Probable chassis Fan or Power Supply Fan failure

CASE

3

Modified

28-Apr-14

 

48950

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_AE_1

ILOM

SPX86-8000-AE

Cache fault on Processor

CASE

2

Modified

28-Apr-14

 

48951

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_CJ_1

ILOM

SPX86-8000-CJ

Data Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48952

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_DC_1

ILOM

SPX86-8000-DC

Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48953

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_EQ_1

ILOM

SPX86-8000-EQ

Instruction Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48954

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_F4_1

ILOM

SPX86-8000-F4

Internal Processor Fault

CASE

2

Modified

28-Apr-14

 

48955

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_GR_1

ILOM

SPX86-8000-GR

Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48956

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_H3_1

ILOM

SPX86-8000-H3

Level 0 Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48957

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_JY_1

ILOM

SPX86-8000-JY

Level 0 Data Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48958

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_KD_1

ILOM

SPX86-8000-KD

Level 0 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48959

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_LH_1

ILOM

SPX86-8000-LH

Level 0 Instruction Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48960

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_MA_1

ILOM

SPX86-8000-MA

Level 0 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48961

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_NP_1

ILOM

SPX86-8000-NP

Level 0 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48962

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_P5_1

ILOM

SPX86-8000-P5

Level 1 Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48963

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_QS_1

ILOM

SPX86-8000-QS

Level 1 Data Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48964

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_RJ_1

ILOM

SPX86-8000-RJ

Level 1 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48965

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_SE_1

ILOM

SPX86-8000-SE

Level 1 Instruction Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48966

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_TX_1

ILOM

SPX86-8000-TX

Level 1 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48967

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_U2_1

ILOM

SPX86-8000-U2

Level 1 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48968

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_VR_1

ILOM

SPX86-8000-VR

Level 2 Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48969

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_W4_1

ILOM

SPX86-8000-W4

Level 2 Data Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48970

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_XQ_1

ILOM

SPX86-8000-XQ

Level 2 Data Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48971

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_YC_1

ILOM

SPX86-8000-YC

Level 2 Instruction Cache Fault on Processor

CASE

2

Modified

28-Apr-14

 

48972

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_0Q_1

ILOM

SPX86-8001-0Q

Level 2 Instruction Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48973

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_1C_1

ILOM

SPX86-8001-1C

Level 2 Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48974

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_2R_1

ILOM

SPX86-8001-2R

Memory Controller fault

CASE

2

Modified

28-Apr-14

 

48975

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_34_1

ILOM

SPX86-8001-34

Initialization failure of the Intel Quickpath Interconnect Physical Layer, Link Layer, or Protocol Layer

CASE

2

Modified

28-Apr-14

 

48976

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_4X_1

ILOM

SPX86-8001-4X

Translation Lookaside Buffer (TLB) Fault on Processor

CASE

2

Modified

28-Apr-14

 

48977

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_ME_1

ILOM

SPX86-8001-ME

 

CASE

2

Modified

28-Apr-14

 

48978

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_QX_1

ILOM

SPX86-8001-QX

Memory DIMM Temperature Sensor Failed

CASE

2

Modified

28-Apr-14

 

48979

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_TS_1

ILOM

SPX86-8001-TS

Memory DIMM Failure During Training

CASE

2

Modified

28-Apr-14

 

48980

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_U5_1

ILOM

SPX86-8001-U5

Memory Uncorrectable ECC Fault

CASE

2

Modified

28-Apr-14

 

48982

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_2J_1

ILOM

SPX86-8002-2J

Power to server not available

CASE

2

Modified

28-Apr-14

 

48985

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_A3_1

ILOM

SPX86-8002-A3

Potentiometers not responding.

CASE

2

Modified

28-Apr-14

 

48991

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8003_73_1

ILOM

SPX86-8003-73

Lack of AC input power.

CASE

3

Modified

28-Apr-14

 

50696

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_0A

ILOM

PCIEX-8000-0A

A problem was detected for a PCIEX device.

CASE

2

New

08-Sep-14

 

50697

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_3S

ILOM

PCIEX-8000-3S

A problem has been detected on one of the specified devices or on one of the specified connecting buses.

CASE

2

New

08-Sep-14

 

50698

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_8R

ILOM

PCIEX-8000-8R

The transmitting device sent an invalid request.

CASE

2

New

08-Sep-14

 

50699

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_DJ

ILOM

PCIEX-8000-DJ

A problem has been detected on one of the specified devices or on one of the specified connecting buses.

CASE

2

New

08-Sep-14

 

50700

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_J5

ILOM

PCIEX-8000-J5

Too many recovered internal errors have been detected within the specified PCIEX device.

CASE

2

New

08-Sep-14

 

50701

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_KP

ILOM

PCIEX-8000-KP

Too many recovered bus errors have been detected, which indicates a problem with the specified bus or with the specified transmitting device.

CASE

2

New

08-Sep-14

 

50702

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_MH

ILOM

PCIEX-8000-MH

Too many recovered errors have been detected, which indicates a problem with the specified PCIEX device.

CASE

2

New

08-Sep-14

 

50703

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_SQ

ILOM

PCIEX-8000-SQ

An uncorrectable error was detected in the PCIe Root Complex.

CASE

2

New

08-Sep-14

 

50704

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_V2

ILOM

PCIEX-8000-V2

A decrease in PCIe link bandwidth has been detected.

CASE

2

New

08-Sep-14

 

50705

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.PCIEX_8000_YJ

ILOM

PCIEX-8000-YJ

Too many recovered bus errors have been detected, which indicates a problem with the specified bus or with the specified transmitting device.

CASE

2

New

08-Sep-14

 

14127

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8000_55_1_EXA

ILOM

SPX86-8000-55

Reviewed 10/28/2011 – Event indicates external feed failure for rack mount servers, or external feed failure or PDU failure for complex products. Review determined this is not an actionable event.

NO_CASE

 

 

 

 

14169

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8001_RP_1_EXA

ILOM

SPX86-8001-RP

Memory DIMM Lacks Temp sensor

NO_CASE

 

 

 

 

14177

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_3E_1_EXA

ILOM

SPX86-8002-3E

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

14178

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_4Q_1_EXA

ILOM

SPX86-8002-4Q

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

14179

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_5C_1_EXA

ILOM

SPX86-8002-5C

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

14191

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_M4_1_EXA

ILOM

SPX86-8002-M4

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

14192

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_NR_1_EXA

ILOM

SPX86-8002-NR

Dave to research - KA indicates that fault will usually be caused by insufficient power. Engineering has determined that this event will likely be caused by power budget configuration.

NO_CASE

 

 

 

 

14193

ODA-X4370_M2

Exadata.ILOM_alarms.ILOMDiagnosis.SPX86_8002_PC_1_EXA

ILOM

SPX86-8002-PC

KA indicates that this event can be caused by shutdown. The fourth suggested action is to replace MB/Blade.

NO_CASE

 

 

 

 

23214

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8000_55_1

ILOM

SPX86-8000-55

Reviewed 10/28/2011 – Event indicates external feed failure for rack mount servers, or external feed failure or PDU failure for complex products. Review determined this is not an actionable event.

NO_CASE

 

 

 

 

23256

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8001_RP_1

ILOM

SPX86-8001-RP

Memory DIMM Lacks Temp sensor

NO_CASE

 

 

 

 

23266

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_5C_1

ILOM

SPX86-8002-5C

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

23278

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_M4_1

ILOM

SPX86-8002-M4

Motherboard/blade replacement is 3rd choice after reloading ILOM image. This event does not have a high probability of being a faulty FRU/CRU.

NO_CASE

 

 

 

 

48983

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_3E_1

ILOM

SPX86-8002-3E

 

NO_CASE

 

Modified

28-Apr-14

 

48984

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_4Q_1

ILOM

SPX86-8002-4Q

 

NO_CASE

 

Modified

28-Apr-14

 

48986

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_NR_1

ILOM

SPX86-8002-NR

 

NO_CASE

 

Modified

28-Apr-14

 

48987

ODA-X4370_M2

Xxx7x.ILOM_alarms.ILOMDiagnosis.SPX86_8002_PC_1

ILOM

SPX86-8002-PC

 

NO_CASE

 

Modified

28-Apr-14

 


Oracle Auto Service Request Fault Coverage – Engineered Systems: Oracle Database Appliance (ODA)