Add Memory to the Server


Caution

Caution  -  These procedures require that you handle components that are sensitive to ESD. Follow antistatic practices to avoid damage or component failure.


Customers can perform this procedure, but the server must first be completely powered down and all power cords unplugged. See Component Service Categories for more information about cold-service procedures.

  1. Review the memory riser and DIMM configuration rules.
  2. Prepare the system for service.
  3. Unplug the power cords.
  4. Remove the memory risers.
  5. Remove any DIMM fillers installed on the memory risers.
  6. Determine your upgrade path.
    • If you are adding DIMMs to the memory risers only, ensure the new DIMMs have the same rank classification as the DIMMs already installed on the motherboard.
    • If you are upgrading all of the memory in the server, remove all of the existing DIMMs on the memory risers and the motherboard.
  7. Install the new DIMMs.
  8. Install the memory risers.
  9. Return the server to operation.
  10. Enable and verify the new DIMMs.