How to Install the Terminal Concentrator in a Cabinet

    This procedure provides instructions for rack-mounting the terminal concentrator in a cabinet. For convenience, you can rack-mount the terminal concentrator even if your cluster does not contain rack-mounted nodes.

  • To rack-mount your terminal concentrator, go to the first step of the following procedure.

  • If you do not want to rack-mount your terminal concentrator, place the terminal concentrator in its standalone location, connect the unit power cord into a utility outlet, and go to How to Connect the Terminal Concentrator.

  1. Install the terminal concentrator bracket hinge onto the primary cabinet:
    1. Locate the bracket hinge portion of the terminal concentrator bracket assembly (see Installing the Terminal Concentrator Bracket Hinge to the Cabinet).
    2. Loosely install two locator screws in the right-side rail of the rear of the cabinet.

      Thread the screws into holes 8 and 29, as shown in Installing the Terminal Concentrator Bracket Hinge to the Cabinet. The locator screws accept the slotted holes in the hinge piece.

    3. Place the slotted holes of the hinge over the locator screws, and let the hinge drop into place.
    4. Install the screws into holes 7 and 28.

      Tighten these screws, and the screws in holes 8 and 29, as shown in Installing the Terminal Concentrator Bracket Hinge to the Cabinet.

      Figure 1  Installing the Terminal Concentrator Bracket Hinge to the Cabinet


      image:Illustration: The preceding context describes the graphic.

  2. Install the terminal concentrator into the bracket.
    1. Place the side pieces of the bracket against the terminal concentrator, as shown in Installing the Terminal Concentrator Into the Bracket.
    2. Lower the terminal concentrator (with side pieces) onto the bottom plate, aligning the holes in the side pieces with the threaded studs on the bottom plate.
    3. Install and tighten three nuts on the three threaded studs that penetrate through each side plate.

      Figure 2  Installing the Terminal Concentrator Into the Bracket


      image:Illustration: The preceding context describes the graphic.

  3. Install the terminal concentrator bracket onto the bracket hinge that is already installed on the cabinet.
    1. Turn the terminal concentrator bracket on its side so the hinge holes and cable connectors face toward the bracket hinge (see Terminal Concentrator Bracket Installed on the Hinge).
    2. Align the bracket holes with the boss pins on the bracket hinge and install the bracket onto the hinge.
    3. Install the keeper screw in the shorter boss pin to ensure the assembly cannot be accidentally knocked off the hinge.

      Figure 3  Terminal Concentrator Bracket Installed on the Hinge


      image:Illustration: The preceding context describes the graphic.

  4. Connect one end of the power cord to the terminal concentrator, as shown in Terminal Concentrator Cable Connector Locations. Connect the other end of the power cord to the power distribution unit.

    Figure 4  Terminal Concentrator Cable Connector Locations


    image:Illustration: The preceding context describes the graphic.

See Also

To cable the terminal concentrator, go to How to Connect the Terminal Concentrator.