Verify a Fan Module

  1. Verify that the Service Required LED on the replaced fan module is not lit.

    See Fan Module LEDs.

  2. Verify that the Top Fan LED and the Service Required LED on the front of the server are not lit.

    See Front Panel Controls and LEDs.


    Note -  If you are replacing a fan module when the server is powered down, the LEDs might stay lit until power is restored to the server and the server can determine that the fan module is functioning properly.
  3. Use the Oracle ILOM show faulty command to verify that the fault has been cleared.

    See Identify Faulted Components for more information on using the show faulty command.

    Consider these two possibilities.

    • If the previous steps did not clear the fault, see Detecting and Managing Faults for information about the tools and methods you can use to diagnose component faults.
    • If the previous steps indicate that no faults have been detected, then the component has been replaced successfully. No further action is required.