Oracle® Identity Management Integration Guide
10g Release 2 (10.1.2) B14085-02 |
|
![]() Previous |
![]() Next |
You can debug the SunONE connector by using the oditest and DIP Tester utilities described in "Troubleshooting Synchronization".
To troubleshoot the SunONE import connector:
Run oditest and enter IplanetImport as the value of the directory synchronization profile argument
Examine the $ORACLE_HOME/ldap/odi/log/IplanetImport.trc and $ORACLE_HOME/ldap/odi/log/IplanetImport.aud files in a text editor for pertinent information
To troubleshoot the SunONE export connector:
Run oditest and enter IplanetExport as the value of the directory synchronization profile argument
Examine the $ORACLE_HOME/ldap/odi/log/IplanetExport.trc and $ORACLE_HOME/ldap/odi/log/IplanetExport.aud files in a text editor for pertinent information
If more than one profile is enabled, then DIP Tester can be run against each of them.