Log file switch (archiving needed) (%)

Description

The system is waiting for a log switch because the log being switched into has not been archived yet.

Metric Summary

The rest of the information in this section is only valid for this metric when it appears in either the Enterprise Manager Grid Control or the Enterprise Manager Database Control (if applicable).

The following table shows how often the metric's value is collected and compared against the default thresholds. The 'Consecutive Number of Occurrences Preceding Notification' column indicates the consecutive number of times the comparison against thresholds should hold TRUE before an alert is generated.

Target Version

Evaluation and Collection Frequency

Upload Frequency

Operator

Default Warning Threshold

Default Critical Threshold

Consecutive Number of Occurrences Preceding Notification

Alert Text

pre-10g

Every Minute

After Every Sample

>

1

5

3

%value%%% of service time is spent waiting on the 'log file switch (archiving needed)' event.

Data Source

(DeltaLogFileSwitchArchTime/DeltaServiceTime)*100 where:

See Idle Events

User Action

Check the alert file to make sure that archiving has not stopped due to a failed archive write. To speed up archiving consider adding more archive processes or putting the archive files on striped disks.

If the archiver is slow, then it might be prudent to prevent I/O contention between the archiver process and LGWR by ensuring that archiver reads and LGWR writes are separated. This is achieved by placing logs on alternating drives.