Siebel Server Sync Guide > Administering Siebel Server Sync > Process of Configuring Email Notification of Synchronization Errors >

Configuring System Alerts for Email Notification of Exchange Connector Synchronization Errors


This topic describes how to configure SSSE so that the administrator receives email notification of errors generated by the Exchange Connector during the inbound synchronization process.

This task is a step in Process of Configuring Email Notification of Synchronization Errors.

To enable email notification of Exchange Connector synchronization errors, perform the following procedure.

To configure system alerts for Exchange Connector synchronization errors

  1. Navigate to Administration - PIM Server Integration, Configuration, and then PIM Server Integration Configuration.
  2. In the PIM Server Integration Configuration list, select the Exchange 2000/2003 Connector profile.
  3. In the Configuration Parameters list, create the following alert parameters, and specify values for the parameters as described:
    Section
    Parameter
    Value

    AdminNotify

    AdminEmailAddress

    A comma delimited email address list of the administrators to be notified

    Example: ssseadmin@sdcexch02.siebel.com

    AdminNotify

    FromAddress

    The originating address of the email notification

    Example: ssseadmin@sdcexch02.siebel.com

    AdminNotify

    SMTPServer

    SMTP server name or IP address through which the email is sent

    Example: mymailserver.company.com

    AdminNotify

    SMTPServerPort

    Port number of the SMTP server

    Example: 25

    AdminNotify

    Message

    Specify the content of the notification email in this field

Siebel Server Sync Guide