Overview: Siebel eBusiness Application Integration Volume l > Error Messages and Troubleshooting Tips > Error Messages for the XML ConverterErrorEAI XML Converter error - empty input message, expecting an XML document in <Value> of input arguments. CauseThe message from the EAI receiver is not included in the input arguments of the EAI XML converter. ResolutionCreate a new process property <Value> in the workflow to hold the message obtained from EAI receiver, then add <value> into the input argument of the EAI XML Converter business service. ErrorEAI XML Converter error - empty input message, expecting an XML document in <Value> of input arguments. CauseNo XML document was passed as an input to the Siebel XML converter. The XML document should be passed in as the <Value> (Message Text) input argument. ResolutionIf you are calling the XML Converter from workflow, then:
If the XML document is generated from a transport, such as MQSeries or HTTP and dispatched to a workflow, then:
ErrorError invoking 'EAI XML Converter', method 'XMLToPropSet' at step 'convert to internal'. CauseThe wrong XML format caused the error. ResolutionCheck the format of the XML message and make sure it is correct. Some common problems include: |