| Bookshelf Home | Contents | Index | Search | PDF | ![]() ![]() |
Siebel Remote and Replication Manager Administration Guide > Administering Siebel Remote >
Refreshing a Client Database
Occasionally, you may need to refresh the local database for a mobile Web client. For example, whenever there is a change to the system preference parameters, a refresh or reextract is necessary for the new settings to take effect. See Setting Siebel Remote System Preferences for more details.
To refresh a client database
- If the mobile Web client has transactions ready for uploading, the user should synchronize and send changes to the server.
- Make sure that the Transaction Merger successfully applied transactions to the server database.
There are three ways to determine when transactions from a particular client have been processed:
- Use the Siebel Server Manager to check whether the Transaction Merger successfully applied transactions for the mobile Web client.
- Inspect the client's inbox directory on the Siebel Remote server. There should not be any files with the .dx extension in the inbox directory.
- Use the Siebel Client Status screen to check whether Transaction Merger successfully applied transactions for the mobile Web client.
- Run Database Extract for the mobile Web client.
Make sure that the parameter Save Transactions is TRUE.
For information on running a database extract, see Creating Mobile Web Client User Accounts and Privileges.
- When you have completed a database extract, notify the user to reinitialize the mobile Web client's local database.
For information on initializing a mobile Web client database, see Initializing a Mobile Web Client Database.
NOTE: After you have performed a database extract for a mobile Web client, the client database must be initialized before any data exchange between the client and the server can occur. This includes the uploading of any client database changes.
| Bookshelf Home | Contents | Index | Search | PDF | ![]() ![]() |
Siebel Remote and Replication Manager Administration Guide, Version 7.5, Rev. A Published: 18 April 2003 |