Siebel Server Administration Guide > Server System Services >

Starting Up and Shutting Down a Siebel Deployment


It is important to follow the correct sequence when starting up or shutting down a Siebel deployment as several dependencies require that certain servers are running before others. Follow the procedures below to start up or shut down your Siebel deployment.

To start up a Siebel deployment

  1. Start up the Siebel Database Server.
  2. Refer to your database documentation for detailed information on this procedure.

  3. Start up the Siebel Gateway service.
  4. Refer to Administering the Siebel Gateway System Service for detailed information on this procedure.

  5. Start up the Resonate service, if applicable. For information on Resonate, see the Siebel Server Installation Guide for the operating system you are using.
  6. Start up the Siebel Server service.
  7. The Siebel Server must connect to the Siebel Gateway and Database on startup. Refer to Administering the Siebel Server System Service for detailed information on the Siebel Server service startup procedure.

To shut down a Siebel deployment

  1. Shut down the Siebel Server service.
  2. When the Siebel Server System Service is shutdown, it shuts down server components and tasks before shutting down itself. Refer to Administering the Siebel Server System Service for detailed information on the shutdown procedure.

  3. Shut down the Resonate service, if applicable. For information on Resonate, see the Siebel Server Installation Guide for the operating system you are using.
  4. Shut down the Siebel Gateway service.
  5. Refer to Administering the Siebel Gateway System Service for detailed information on this procedure.

  6. Shut down the Siebel Database Server.
  7. Refer to your database documentation for detailed information on this procedure.


 Siebel Server Administration Guide, Version 7.5, Rev. C 
 Published: 18 April 2003