Siebel Financial Services Connector for ACORD P&C and Surety Guide > Troubleshooting > Envelope Problem >

Message does not show user-selected information


Problem

A user chooses header elements while generating an envelope integration object, but the resulting message for initial request does not show the chosen header information.

Solution

When a user creates a user-defined envelope integration object, all the user-chosen tags are memorized in the userdefined user property of each integration component of the envelope integration object. The value of this user property of each integration component indicates the names of its child integration components.

In the workflow, find the business service corresponding to the "PropsetToXMLPropSet" method of the FINS ACORD XML Converter. Change the value of the input argument from initsignon to userdefined. Doing so causes the user property userdefined to be used to construct the initial SignonRq header instead of the default value initsignon. The SignonRq header will reflect the user-chosen elements.


 Siebel Financial Services Connector for ACORD P&C and Surety Guide 
 Published: 18 April 2003