Siebel Data Warehouse Installation and Administration Guide > Installing and Configuring the Siebel Data Warehouse > Configuring the Informatica Servers >

Configuring the Informatica Service


This configuration follows the installation of the Informatica servers.

To configure the Informatica Service

  1. The Configure Informatica Service screen appears. Make sure the settings shown in the following table are selected for each tab.
    Click for full size image
    Tab
    Information Required
    Keys
    Enter the applicable license keys for your installation. When finished, click OK. (Obtain the license key information from the license key letter.)
    Server
    Configure SIEBEL_DW_SERVER. In the Load Manger section, make sure that the maximum number of concurrent sessions is not greater than 15 and shared memory is not greater than 3000000.
    Configuration
    Specify whether to use ASCII or UNICODE. If you select UNICODE, clear the Validate Data Codepages check box.
    Compatibility and Database
    Make sure that the Database settings section Treat CHAR as CHAR on read is selected and that the maximum number of connections is 100.
    Repository
    Enter the repository name (Siebel_DW_Rep), the repository user and password, the repository server host name, and the repository server port number (5001). Click OK.
  2. In the Informatica Server Setup Application—Options screen, click Exit.
  3. In the Setup Complete screen, click Finish.

 Siebel Data Warehouse Installation and Administration Guide
 Published: 09 September 2004