Transports and Interfaces: Siebel eBusiness Application Integration Volume III > EAI Transports and Interfaces Overview >

Configuring Named Subsystems and Receiver Server Components


This section explains how to configure named subsystems for the MQSeries AMI Receiver server component.

To configure the Default Tasks parameter

  1. From the application-level menu, choose View > Site Map > Server Administration view >Enterprise Configuration.
  2. Click the Enterprise Component Groups tab.
  3. A list of receivers appears in the Enterprise Component Groups applet, for example, MQSeries AMI Receiver.

  4. Select Components from the Server Administration view.
  5. Click the Component Parameters tab.
  6. Select the MQSeries AMI Receiver in the Server Components List applet.
  7. Query for the Default Tasks parameter in the Component Parameters applet.
  8. Set the value for the Default Tasks parameter to 1, or any number equal to the number of tasks that will be started for the component.

To create a connection subsystem

  1. From the application-level menu, choose View > Site Map > Server Administration view > Enterprise Configuration.
  2. Click the Enterprise Profile Configuration tab.
  3. In the Component Profiles List applet, create a new Named Subsystem record.
    1. Enter MyAMISubsys in the Named Subsystem Alias column.
    2. Select MQSeriesAMISubsys as the type.
    3. In the Enterprise Profile Configuration applet, specify the values for each of the connection parameters for the AMI receiver, such as MqLocalHostFileName.

To create a data handling subsystem

  1. From the application-level menu, choose View > Site Map > Server Administration view >Enterprise Configuration.
  2. Click on the Enterprise Profile Configuration tab.
  3. In the Component Profiles List applet, create a new Named Subsystem record.
    1. Enter MyDispSubsys in the Named Subsystem Alias column.
    2. Select EAITransportDataHandlingSubsys as the type.
  4. In the Enterprise Profile Configuration applet, specify the values for each of the data handling parameters for the AMI receiver, such as Dispatch Service.

To start the Receiver Server task

  1. From the application-level menu, choose View > Site Map > Server Administration view > Servers.
  2. Click the Server Components tab.
  3. In the Server Components applet, select the MQSeries AMI Receiver.
  4. Click the Shutdown button.
  5. Wait for the component state to change to Shutdown.

  6. Click Startup to restart the Receiver.
  7. Observe that the Component State now changes to Online, and the value for Running Tasks changes to the number of Default Tasks specified previously.

To specify named subsystems in a workflow

  1. From the application-level menu, choose View > Site Map > Business Process Administration > Workflow Processes.
  2. Query and select the workflow process named MyMQOutbound.
  3. Double-click the MQ Send step.
  4. In the Input Arguments Applet, insert a new record to specify the Connection subsystem, and specify the value as MyAMISubsys.
  5. Insert another input argument to specify the Data Handling Subsystem, and specify the value as MyDispSubsys.
  6. Insert a third record to specify the Message Text.

 Transports and Interfaces: Siebel eBusiness Application Integration Volume III 
 Published: 23 June 2003