Siebel Analytics Web Services Guide > Description of Siebel Analytics Web SOAP API Methods > WebCatalogService Service >

writeDashboardPage() Method


The writeDashboardPage() method writes a dashboard page to the Web Catalog.

Signature

void writeDashboardPage(CatalogObject object, String path, boolean resolveLinks, boolean allowOverwrite, String sessionID);

Arguments
Description

CatalogObject object

The dashboard page object to write to the Web Catalog, supplied in the CatalogObject structure. For information about the CatalogObject structure, read CatalogObject Structure.

All fields of object.itemInfo are ignored, except for the array of item properties, which are applied to the object. The signature of the resulting document is always dashboardpageitem1.

String path

The location in the Web Catalog where the dashboard page should be written.

boolean resolveLinks

A boolean value, 1 (true) or 0 (false). When set to true, and the path in the Web Catalog refers to a link, the dashboard page is written to the location pointed to by the link.

boolean allowOverwrite

A boolean value, 1 (true) or 0 (false). When set to true, if the dashboard page already exists in the Web Catalog, it will be overwritten. When set to false, if the dashboard page already exists in the Web Catalog, it will not be overwritten.

String sessionID

A character string that contains the session ID. The session ID is usually returned by the logon call. If the SOAP client engine can handle HTTP cookies, you can omit the session ID or set it to null.

Siebel Analytics Web Services Guide