The TUXEDO System application was unable to unregister the DBBL process
because another DBBL was found to have been booted already.
No action required.
While loading a
TUXCONFIG
file using
tmloadcf ,
the device and offset specified by the
TUXCONFIG
and
TUXOFFSET
environment variables,
device1
and
offset1,
don't match the information stored for the first
entry in the configuration file,
device2
and
offset2.
This occurs when the device (file) is moved from one name to
another.
Remove the configuration file before loading it with
tmloadcf .
tmloadcf (1)
The value for the
TLOGDEVICE
parameter as specified in the *MACHINES
section of the
UBBCONFIG
file must be an absolute pathname. Relative
paths and environment variables are not valid.
Correct the value for
TLOGDEVICE
as specified in the *MACHINES section
of the
UBBCONFIG
file to be an absolute pathname.
ubbconfig (5)
The
BUFTYPE
parameter of a SERVICES section entry or ROUTING section entry in the
UBBCONFIG file specified duplicate type/subtype pairs.
(For types without any subtype specified, the
BUFTYPE
parameter specified duplicate type pairs.)
Modify the
BUFTYPE
parameter so that the same type/subtype pair is not specified more than once.
Reload the configuration file.
ubbconfig (5)
If multiple entries exist in the SERVICES section with the same service name
but with different
SRVGRP
parameters, the
BUFTYPE
parameter must be the same for all of the entries.
This rule was violated for the service entry named in the error message.
Specify the same
BUFTYPE
parameters for all instances of a particular service name.
Then reload the configuration file.
ubbconfig (5)
The files in your TUXEDO System installation
do not contain the expected software license information,
such as the maximum number of licensed users.
The installation program prompted the installer for this information
at installation time.
Reinstall the TUXEDO System software,
using the license token and serial number
supplied with the distribution media.
Make sure not to terminate the installation program prematurely,
because the license information is processed at the end.
See Message No. 1606 above.
See Message No. 1606 above.
Your copy of the TUXEDO System software is an evaluation copy,
and the expiration date has passed.
If you wish to continue using the TUXEDO System,
contact the company from which you received the the product.
See Message No. 1609 above.
See Message No. 1609 above.
The device specified for the \-d option of
tlisten
does not exist or is not a character special device.
If the sockets network provider is being used, the device is not needed
and will be ignored.
If the TLI network provider is being used, the network open will fail.
If TLI is being used, specify the correct network device pathname.
tlisten (1)
While parsing a UBBCONFIG file, invalid syntax was found.
This generally occurs when a keyword or operator is missing (for example,
two numbers appear together).
Correct the syntax and re-load the configuration file.
ubbconfig(5)
An administrative request generated by
tmboot
to the remote
machine indicated in subsequent messages produced to
stderr
was rejected because either an invalid administrative
password was passed to the remote site or no administrative
password was available to be passed to the remote site.
If no administrative password was specified locally,
then determine an appropriate administrative password and set the local
environment to pass it to remote sites as indicated in
tmboot .
If an administrative password was specified locally, then either the local
setting will have to change to match that expected by the remote site, or
the administrative password used by this application will have to be added
to the password file used by
tlisten
on the remote site.
tmboot (1),
tlisten (1)
While parsing a UBBCONFIG file, an invalid machine name was specified.
The name has a value of the form "name.number" (this is restricted
only in the development copy, compiled to allow what is called "fake mp").
Correct the syntax error and re-load the configuration file.
ubbconfig(5)
While parsing a UBBCONFIG file, an invalid LMID value was found.
The LMID value contains a comma.
Correct the syntax and re-load the configuration file.
ubbconfig(5)
While parsing a UBBCONFIG file, an invalid LMID value was found.
The LMID value contains a comma.
Correct the syntax and re-load the configuration file.
ubbconfig(5)
An attempt was made to boot a 4.2.x site into an application with more
than number configured machines.
Either reduce the number of configured machines and reboot the site, or
upgrade the site to release 5.0.x or later.
"TUXEDO Administrator's Guide"
The
MAXMACHINES
parameter in the
*RESOURCES
section of the ubbconfig(5) file was specified outside of the
acceptable range of number to 8190.
Correct the ubbconfig(5) value for this parameter and rerun
tmloadcf(1).
"TUXEDO Administrator's Guide" ,
tmloadcf (1),
ubbconfig (5)
The
MAXQUEUES
parameter in the
*RESOURCES
section of the ubbconfig(5) file was specified outside of the
acceptable range of 1 to 8191.
Correct the ubbconfig(5) value for this parameter and rerun
tmloadcf(1).
"TUXEDO Administrator's Guide" ,
tmloadcf (1),
ubbconfig (5)
An attempt was made to boot a 4.2.x site with the
MAXQUEUES
and
MAXSERVERS
parameters in the
*RESOURCES
section of the ubbconfig(5) file set to different values.
Either reconfigure the application to have equivalent values for these
parameters and reboot the site, or upgrade the 4.2.x site to release 5.0.x or later.
"TUXEDO Administrator's Guide" ,
tmloadcf (1),
ubbconfig (5)
The
MAXGROUPS
parameter in the
*RESOURCES
section of the ubbconfig(5) file was specified outside of the
acceptable range of number to 32767.
Correct the ubbconfig(5) value for this parameter and rerun
tmloadcf(1).
"TUXEDO Administrator's Guide" ,
tmloadcf (1),
ubbconfig (5)
The
CMPLIMIT
parameter in the
*MACHINES
section of the ubbconfig(5) file has been specified with an
invalid value string.
Correct the value for this parameter to the acceptable format
and rerun tmloadcf(1).
The acceptable format for this parameter is
remote[,local] where both remote and local
may be either the string
MAXLONG
or a non-negative numeric value.
"TUXEDO Administrator's Guide" ,
tmloadcf (1),
ubbconfig (5)
The
NETLOAD
parameter in the
*MACHINES
section of the ubbconfig(5) file was specified as a negative value.
Correct the ubbconfig(5) value for this parameter and rerun
tmloadcf(1).
"TUXEDO Administrator's Guide" ,
tmloadcf (1),
ubbconfig (5)
The
SPINCOUNT
parameter in the
*MACHINES
section of the ubbconfig(5) file was specified as a negative value.
Correct the ubbconfig(5) value for this parameter and rerun
tmloadcf(1).
"TUXEDO Administrator's Guide" ,
tmloadcf (1),
ubbconfig (5)
The application was configured to handle up to number configured
server groups (see the
MAXGROUPS
parameter in the
*RESOURCES
section of the ubbconfig(5) file) and has excess server groups defined
in the ubbconfig(5) file.
Either reset the
MAXGROUPS
parameter in the
*RESOURCES
section or delete server groups from the
*GROUPS
section of the ubbconfig(5) file and rerun tmloadcf(1).
"TUXEDO Administrator's Guide" ,
tmloadcf (1),
ubbconfig (5)
The application was configured to handle up to number configured
machines (see the
MAXMACHINES
parameter in the
*RESOURCES
section of the ubbconfig(5) file) and has excess machines defined
in the
*MACHINES
section of the ubbconfig(5) file.
Either reset the
MAXMACHINES
parameter in the
*RESOURCES
section or delete machines from the
*MACHINES
section of the ubbconfig(5) file and rerun tmloadcf(1).
"TUXEDO Administrator's Guide" ,
tmloadcf (1),
ubbconfig (5)
An invalid opcode number was sent to the tagent process.
The most likely cause of this problem is a non-TUXEDO System process incorrectly
connecting to the TUXEDO System listener (tlisten(1)) process and attempting
to interact with the tagent. In this case, the non-TUXEDO System process
should be changed to not connect to tlisten.
If this is not the case, then contact your TUXEDO System Technical Support
for further assistance.
The configured value num1 for the maximum number of configured
groups in the application (see the
MAXGROUPS
parameter in the
*RESOURCES
section of the ubbconfig(5) file) is not set to the value num2
required for interoperability with release num3.
Either modify the value of this parameter in the configuration file and
rerun tmloadcf(1), or upgrade the site in question to a later release
of the TUXEDO System.
"TUXEDO Administrator's Guide" ,
tmloadcf (1),
tmunloadcf (1),
ubbconfig (5)
Master migration from a release num1 site to a num2 site was
attempted.
Change the backup site to be one of the same release as the master site.
"TUXEDO Administrator's Guide" ,
tmadmin (1),
tmloadcf (1),
ubbconfig (5)
The backup master site attempted to boot with an invalid release number.
Either change the backup master site to one of the same release as the
master site, or upgrade the backup master site release.
"TUXEDO Administrator's Guide" ,
tmadmin (1),
tmboot (1),
tmloadcf (1),
ubbconfig (5)
A BBL attempted to boot into an application with a master site running an
older release than its own, number.
Either run the older release on the site in question, or upgrade the master
site to be one running the latest TUXEDO System release desired.
The
SVCTIMEOUT
parameter in the
*SERVICES
section of the ubbconfig(5) file was specified as a negative value.
Change the parameter value in the ubbconfig(5) file and rerun
tmloadcf(1).
"TUXEDO Administrator's Guide" ,
tmloadcf (1),
ubbconfig (5)
The BBL could not abortively deactivate the server with process id pid
after the server exceeded the configured
SVCTIMEOUT
value for the service it was currently processing.
Contact your TUXEDO System Technical Support.
"TUXEDO Administrator's Guide" ,
tmloadcf (1),
ubbconfig (5),
kill (2)
in UNIX reference manuals
The BBL has terminated the local server with process id pid
using the kill(2) system call to generate a
SIGKILL
signal because the server exceeded the maximum service processing time
for the current service as configured via the
SVCTIMEOUT
parameter in the
*SERVICES
section of the ubbconfig(5) file.
Either increase the configured service timeout value, or modify the
server to complete the service within the allotted time interval.
"TUXEDO Administrator's Guide" ,
tmloadcf (1),
ubbconfig (5),
kill (2)
in UNIX reference manuals
1600 ERROR: Unable to register - another DBBL already exists on machine
DESCRIPTION
ACTION
1601 ERROR: TUXCONFIG,TUXOFFSET device1, offset1 doesn't match first device entry on configuration device2, offset2
DESCRIPTION
ACTION
SEE ALSO
1603 ERROR: TLOGDEVICE must be an absolute pathname
DESCRIPTION
ACTION
SEE ALSO
1604 ERROR: section_name entry entry_name - duplicate type(type_name)/subtype(subtype_name)
DESCRIPTION
ACTION
SEE ALSO
1605 ERROR: SERVICES entry entry_name - must have the same BUFTYPE for all SERVICE entries.
DESCRIPTION
ACTION
SEE ALSO
1606 ERROR: Unlicensed TUXEDO System Binary
DESCRIPTION
ACTION
1607 ERROR: Unlicensed TUXEDO System Binary
DESCRIPTION
ACTION
1609 ERROR: Expired TUXEDO System Binary
DESCRIPTION
ACTION
1610 ERROR: Expired TUXEDO System Binary
DESCRIPTION
ACTION
1614 WARN: Network device does not exist
DESCRIPTION
ACTION
SEE ALSO
1615 ERROR: Identifier or number must be followed by white space or punctuation
DESCRIPTION
ACTION
SEE ALSO
1624 ERROR: Invalid or unspecified administrative password
DESCRIPTION
ACTION
SEE ALSO
1626 ERROR: Machine "pmid" cannot be of the form "name.number"
DESCRIPTION
ACTION
SEE ALSO
1627 ERROR: LMID "value" must not contain comma
DESCRIPTION
ACTION
SEE ALSO
1628 ERROR: LMID "value" must not contain comma
DESCRIPTION
ACTION
SEE ALSO
1629 ERROR: Cannot allow only release 4.2.x BBLs to join system with a configuration of number machines or more
DESCRIPTION
ACTION
SEE ALSO
1631 ERROR: MAXMACHINES parameter must be >= number and < 8191
DESCRIPTION
ACTION
SEE ALSO
1633 ERROR: MAXQUEUES parameter must be > 0 and < 8192
DESCRIPTION
ACTION
SEE ALSO
1634 ERROR: MAXQUEUES(number) and MAXSERVERS(number) must be equal to interoperate with release number
DESCRIPTION
ACTION
SEE ALSO
1636 ERROR: MAXGROUPS parameter must be >= number and < 32768
DESCRIPTION
ACTION
SEE ALSO
1638 ERROR: Invalid CMPLIMIT value string
DESCRIPTION
ACTION
SEE ALSO
1640 ERROR: NETLOAD parameter must be >= 0
DESCRIPTION
ACTION
SEE ALSO
1642 ERROR: SPINCOUNT parameter must be >= 0
DESCRIPTION
ACTION
SEE ALSO
1643 ERROR: More than MAXGROUPS(number) groups in configuration file
DESCRIPTION
ACTION
SEE ALSO
1644 ERROR: More than MAXMACHINES(number) machines in configuration file
DESCRIPTION
ACTION
SEE ALSO
1645 ERROR: Illegal opcode (number) sent to tagent
DESCRIPTION
ACTION
1646 ERROR: MAXGROUPS(num1) must be num2 to interoperate with release num3
DESCRIPTION
ACTION
SEE ALSO
1647 ERROR: Cannot migrate master from release num1 to release num2
DESCRIPTION
ACTION
SEE ALSO
1649 ERROR: Backup master is running invalid release number
DESCRIPTION
ACTION
SEE ALSO
1651 ERROR: Cannot join system with DBBL running older release number
DESCRIPTION
ACTION
1655 ERROR: SVCTIMEOUT parameter must not be < 0
DESCRIPTION
ACTION
SEE ALSO
1666 WARN: Could not terminate server(pid) processing after SVCTIMEOUT
DESCRIPTION
ACTION
SEE ALSO
1667 WARN: Server(pid) processing terminated after SVCTIMEOUT
DESCRIPTION
ACTION
SEE ALSO