4002
ERROR: Syntax Error in the -g argument.
Description
Each group specified by the -g argument of tpacladd(1) or tpaclmod(1) must be greater than 0 characters and less than 31 characters.
-g
tpacladd
tpaclmod
Action
Modify the -g argument so that the group identification falls within acceptable limits.
4003
4004
ERROR: Could not retrieve group information.
When tpacladd(1) or tpaclmod(1) was attempting to retrieve information about one of the groups specified by the -g argument, an error occurred.
Try the command again. If it fails consistently, contact your BEA TUXEDO system Technical Support.
4005
ERROR: Group number does not exist.
tpacladd(1) or tpaclmod(1) encountered a group number given via the -g parameter which does not exist.
Add the desired group to the T_ACLGROUP class by using the tpgrpadd(1) command, and then re-run this command.
T_ACLGROUP
tpgrpadd
4006
ERROR: Group groupname does not exist.
tpacladd(1) or tpaclmod(1) encountered a group name given via the -g parameter which does not exist.
4008
ERROR: type field is not valid.
The type field given via the -t option to tpacladd(1), tpaclmod(1), or tpacldel(1) was invalid. The only recognized types are SERVICE, ENQ, DEQ, or POSTEVENT.
-t
tpacldel
SERVICE
ENQ
DEQ
POSTEVENT
Change the -t option of the command being run to SERVICE, ENQ, DEQ, or POSTEVENT.
4010
ERROR: name field is not valid.
The name given to tpacladd(1), tpaclmod(1), or tpacldel(1) was invalid. An ACL name must not contain the characters '#', ':' or newline. Furthermore, the name must be less than or equal to 30 characters in length.
Change the name given to the command in order to comply with the specifications.
4011
ERROR: FML32 error error.
When adding or deleting a field from an FML buffer, the given error occurred. This error occurs when running tpacladd(1), tpaclmod(1), or tpacldel(1).
Try running the command again. If it fails consistently, contact your BEA TUXEDO system Technical Support.
4012
ERROR: Memory allocation error.
When using the command tpacladd(1), tpaclmod(1), or tpacldel(1), the system ran out of memory.
Check the memory on the system where the command was run. If it seems that there should be enough memory for this operation, contact your BEA TUXEDO system Technical Support.
4014
ERROR: TUXCONFIG is not set.
tpacladd(1), tpaclmod(1), and tpacldel(1) must be run on configured systems. Furthermore, the TUXCONFIG variable must point to the BEA TUXEDO configuration file.
TUXCONFIG
Configure the application (see ubbconfig(5) and tmloadcf(1)). Set your TUXCONFIG variable appropriately. Run tmloadcf(1). Then re-run the command that caused this error.
ubbconfig
tmloadcf
4018
ERROR: Unknown executable name.
The given executable name is not known. This error can happen if the tpgrpadd(1), tpgrpdel(1), or tpgrpmod(1) commands have been renamed.
tpgrpdel
tpgrpmod
Do not rename the tpgrpadd(1), tpgrpmod(1), or tpgrpdel(1) commands. Use the original names with which the BEA TUXEDO system binary was packaged.
4019
ERROR: MIB error number.
When running the tpacladd(1), tpaclmod(1), or tpacldel(1) command, an error occurred in the MIB(5). The returned error number was retrieved from the TA_ERROR field of the returned FML32 buffer.
MIB
TA_ERROR
Consult the MIB(5) reference pages to determine exactly which error was returned. Further action may be suggested by the nature of the error returned by the MIB.
4020
ERROR: grpname field is not valid.
The group name given to tpgrpadd(1), tpgrpmod(1), or tpgrpdel(1) was invalid. A group name must not contain the characters '#', ',', ':' or newline. Furthermore, the name must be less than or equal to 30 characters in length.
Change the group name given to the command in order to comply with the specifications.
4021
When running the tpgrpadd(1), tpgrpmod(1), or tpgrpdel(1) command, an error occurred in the MIB(5). The returned error number was retrieved from the TA_ERROR field of the returned FML32 buffer.
4022
When adding or deleting a field from an FML32 buffer, the given error occurred. This error occurs when running tpgrpadd(1), tpgrpmod(1), or tpgrpdel(1).
Try running the command again. If it continues to fail, contact your BEA TUXEDO system Technical Support.
4023
When using the commands tpgrpadd(1), tpgrpmod(1), or tpgrpdel(1), the system ran out of memory.
Make sure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
4024
4025
tpgrpadd(1), tpgrpmod(1), and tpgrpdel(1) must be run on configured systems. Furthermore, the TUXCONFIG variable must point to the BEA TUXEDO configuration file.
4026
ERROR: new group name is not valid.
The new group name given to tpgrpmod(1) was invalid. A group name must not contain the characters '#', ',', ':' or newline. Furthermore, the name must be less than or equal to 30 characters in length.
Change the new group name given to the command in order to comply with the specifications.
4027
When tpgrpadd(1) or tpgrpmod(1) was attempting to retrieve information about groups specified on the command line, an error occurred.
Try the command again. If the command fails consistently, contact your BEA TUXEDO system Technical Support.
4028
ERROR: groupname group already exists.
In the T_ACLGROUP class, no two groups can have the same name. tpgrpmod(1) attempted to add two groups with the same name.
Do not attempt to have two groups with the same name. Change the group name and re-run the command.
4029
tpgrpmod(1) attempted to modify a group that does not exist.
Use tpgrpadd(1) to add new groups to the T_ACLGROUP class. Use the BEA TUXEDO GUI to get a complete list of the currently defined groups.
4030
When adding or deleting a field from an FML32 buffer, the given error occurred. This error occurs when running tpusradd(1), tpusrmod(1), or tpusrdel(1).
tpusradd
tpusrmod
tpusrdel
Try running the command again. If it fails again, contact your BEA TUXEDO system Technical Support.
4031
When using the commands tpusradd(1), tpusrmod(1), or tpusrdel(1), the system ran out of memory.
4032
When tpusradd(1) or tpusrmod(1) was attempting to retrieve information about a group specified on the command line, an error occurred.
4033
tpusradd(1) or tpusrmod(1) encountered a group number given via the -g parameter which does not exist.
4034
tpusradd(1) or tpusrmod(1) encountered a group name given via the -g parameter which does not exist.
4038
The given executable name is not known. This error can happen if the tpusradd(1), tpusrdel(1), or tpusrmod(1) commands have been renamed.
Do not rename the tpusradd(1), tpusrmod(1), or tpusrdel(1) commands. Use the original names with which the BEA TUXEDO binary was packaged.
4039
tpusradd(1), tpusrmod(1), and tpusrdel(1) must be run on configured systems. Furthermore, the TUXCONFIG variable must point to the BEA TUXEDO configuration file.
4040
ERROR: Security level must be USER_AUTH, ACL or MANDATORY_ACL.
In order to run tpacladd(1), tpaclmod(1), or tpacldel(1), the security level of the BEA TUXEDO application must be USER_AUTH, ACL, or MANDATORY_ACL.
USER_AUTH
ACL
MANDATORY_ACL
Change the security level in the ubbconfig(5) file to USER_AUTH, ACL, or MANDATORY_ACL. Run tmloadcf(1) on the new ubbconfig(5) file. Then re-run the command that caused this failure.
4043
ERROR: username user already exists.
In the T_ACLPRINCIPAL class, no two users can have the same numeric identification. tpusrmod(1) attempted to add two users with the same identification.
T_ACLPRINCIPAL
Do not attempt to have two users with the same numeric identification. Change the user name and re-run the command.
4044
ERROR: User username does not exist.
tpusrmod(1) attempted to modify a user which does not exist.
Use tpusradd(1) to add new users to the T_ACLPRINCIPAL class. Use the BEA TUXEDO GUI to get a complete list of the currently defined users.
4045
ERROR: usrname field is not valid.
The user name given to tpusradd(1), tpusrmod(1), or tpusrdel(1) was invalid. A user name must not contain the characters '#', ':' or newline. Furthermore, the name must be less than or equal to 30 characters in length.
4046
ERROR: Invalid group specified.
The group name given to tpusradd(1) or tpusrmod(1) was invalid. Either the group did not exist or there was a syntax error in the group name.
Use tpgrpadd(1) to add new groups. Change the group name given to the command to correspond to an existing group. Change the group name to conform to the specifications for group names.
4047
ERROR: User numbers must be between 1 and max
User numbers in the T_ACLPRINCIPAL class must be between 1 and 131071. A user number presented to tpusradd(1) or tpusrmod(1) was not within that range.
Change the user number to be within the allowable range and re-run the command.
4048
When running the tpusradd(1), tpusrmod(1), or tpusrdel(1) command, an error occurred in the MIB(5). The returned error number was retrieved from the TA_ERROR field of the returned FML32 buffer.
4049
ERROR: A group with id number already exists.
In the T_ACLGROUP class, no two groups can have the same numeric identification. tpgrpadd(1) or tpgrpmod(1) attempted to add two groups with the same identification.
Do not attempt to have two groups with the same numeric identification. Change the identification number and re-run the command.
4050
ERROR: A user with id number already exists.
In the T_ACLPRINCIPAL class, no two users can have the same numeric identification. tpusradd(1) or tpusrmod(1) attempted to add two users with the same identification.
Do not attempt to have two users with the same numeric identification. Change the identification number and re-run the command.
4053
ERROR: User username not added.
Due to an error processing the user password, this user has not been added to the system. This can happen when using tpusradd(1) or tpusrmod(1).
Re-run the command that caused the error. If this error occurs consistently, call BEA TUXEDO system Technical Support.
4054
ERROR: Passwords do not match.
The user passwords entered to tpusradd(1) or tpusrmod(1) do not match.
Re-run the command and make sure that you enter the passwords correctly each time you are prompted.
4055
ERROR: Unable to get host user id.
tpusradd(1), tpusrmod(1), or tpusrdel(1) was unable to retrieve the user identification from the host system.
Make sure that the user id of the BEA TUXEDO administrator is known to the system. If the user id is known to the system, contact your BEA TUXEDO system Technical Support.
4056
tpacladd(1), tpaclmod(1), or tpacldel(1) was unable to retrieve the user identification from the host system.
4057
tpgrpadd(1), tpgrpmod(1), or tpgrpdel(1) was unable to retrieve the user identification from the host system.
4058
INFO: .SysMachineState: val state change to ACTIVE
This message states that the specified machine changed to ACTIVE. A complete listing of the current parameters are sent along in the posted buffer.
This is an informational message.
See Also
EVENT_MIB(5), TM_MIB(5)
EVENT_MIB
TM_MIB
4060
The given executable name is not known. This error can happen if the tpacladd(1), tpacldel(1), or tpaclmod(1) commands have been renamed.
Do not rename the tpacladd(1), tpaclmod(1), or tpacldel(1) commands. Use the original names with which the BEA TUXEDO system binary was packaged.
4062
4063
INFO: .SysNetworkState: LMID1->LMID2 state change to INACTIVE
This message indicates that the virtual circuit between machines LMID1 and LMID2 changed to an INACTIVE state. A complete listing of the current parameters are sent along in the posted buffer.
4064
INFO: .SysMachineState: LMID state change to PARTITIONED
This message states that the specified machine changed to a new state as mentioned in the message. A complete listing of the current parameters are sent along in the posted buffer.
4065
INFO: .SysNetworkState: LMID1->LMID2 state change to ACTIVE
This message indicates that the virtual circuit between machines LMID1 and LMID2 changed to a new state as mentioned in the message. A complete listing of the current parameters are sent along in the posted buffer.
4066
INFO: .SysNetworkState: LMID1->LMID2 state change to SUSPENDED
This message indicates that the virtual circuit between machines LMID1 and LMID2 changed to a SUSPENDED state. A complete listing of the current parameters are sent along in the posted buffer.
4068
INFO: .SysServerState: servername, group srvgrp, id srvid state change to state
This message indicates that the server specified above changed to a new state. A complete listing of the server attributes are sent in the posted buffer.
4069
INFO: .SysClientState: User usrname on LMID state change to state
This message indicates that the client specified above changed to a new state. A complete listing of the current attributes of the client are sent in the posted buffer.
4070
ERROR: Application must be configured.
4071
4072
4073
INFO: .SysNetworkConfig: LMID1->LMID2 configuration change
This message indicates that the network link between the two machines specified changed to a new state. A complete listing of the current parameters are sent along in the posted buffer.
4075
INFO: .SysMachineState: LMID state change to INACTIVE
This message states that the specified machine changed to an INACTIVE state. A complete listing of the current parameters are sent along in the posted buffer.
4076
ERROR: .SysEventDelivery: System Event Monitor delivery failure on LMID
This message indicates that the event server failed to perform at least one notification for a posted event.
Check to make sure that the notifications specified in the subscriptions that match the posted events can be done.
4077
ERROR: .SysEventFailure: System Event Monitor subsystem failure on LMID
The system event server periodically sends a message to itself to detect blocking conditions on the message queues. This event is generated if the server can't put a message on the queue in no-block node. It can also be generated if the received message doesn't match what was sent out earlier. The second case will probably never happen.
Configure larger message queues or distribute the load in the application equally among all the machines.
4078
ERROR: Memory allocation failure
Memory allocation failed in the event server.
4080
ERROR: Message received did not match sent message
The event server periodically tests the message queue subsystem for blocking conditions by sending a message to itself in NOWAIT mode and receiving the message right after. This message indicates that the received message didn't match the sent message.
NOWAIT
Contact your BEA TUXEDO system Technical Support.
TMSYSEVT(5), TMUSREVT(5)
TMSYSEVT
TMUSREVT
4081
When adding or deleting a field from an FML32 buffer, the given error occurred. This error occurs when running tpaclcvt(1).
tpaclcvt
4082
When using the command tpaclcvt(1), the system ran out of memory.
4083
INFO: Line number not added because it is a comment.
The given line number in the user file was ignored by tpaclcvt(1). The line was not formatted correctly, and hence was ignored.
Be sure that the file which is being converting has the correct format.
4084
INFO: User ID field field is not numeric. Line number not added.
If tpaclcvt(1) encounters a user identification number which is not numeric, then it does not attempt to add the user. This can occur when converting the user file.
Be sure that the file which is being converted has the correct format.
4085
INFO: User ID number is invalid. Line number not added.
User identification numbers are only valid within the range 1 to 131,071. If tpaclcvt(1) encounters a user identification number which is not in the given range, then it does not attempt to add the user.
Any users which tpaclcvt(1) could not add can be added with tpusradd(1).
4086
INFO: Group ID field number is not numeric. Line number not added.
If tpaclcvt(1) encounters a group identification number which is not numeric, then it does not attempt to add the user. This can occur when converting the user file.
4087
INFO: Line number not added. # is an illegal character.
The given line in the user file was not converted by tpaclcvt(1). This is because a # character was encountered in the username, which is illegal.
4088
INFO: Line number not added. error_string.
tpaclcvt(1) encountered an error when attempting to get information concerning the user on the given line.
Examine the error code returned. This error can be used to determine the actual BEA TUXEDO system error that occurred.
4089
INFO: Line number user name not added. Error retrieving number of occurrences.
When tpaclcvt(1) is converting a user file, it attempts to look for duplicate users. If an error occurs while extracting the number of users, this message occurs.
4090
INFO: Line number user username not added. User username already exists.
You can add any user which tpaclcvt(1) did not add with tpusradd(1).
4091
tpaclcvt(1) encountered an error when attempting to get information concerning user identifiers.
4092
When tpaclcvt(1) is converting a user file, it attempts to look for duplicate users identification numbers. If an error occurs while extracting the number of user identifiers, this message occurs.
4093
INFO: Line number user usernumber not added. User usernumber already exists.
tpaclcvt(1) did not add the given user because that user identification number already exists.
4094
INFO: Line number user username not added. Error writing file.
tpaclcvt(1) was attempting to modify the user file to add the given user.
Run a diagnostic on the disk to see whether the disk is corrupted. If it is corrupted, buy a new disk and run the command again. If it is not, contact BEA TUXEDO system Technical Support.
4095
The given line number in the group file was ignored by tpaclcvt(1). The line was not formatted correctly, and hence was ignored.
4096
INFO: Group ID field string is not numeric. Line number not added.
If tpaclcvt(1) encounters a group identification number that is not numeric, then it does not attempt to add the user. This can occur when converting the group file.
Any groups which tpaclcvt(1) could not add can be added with tpgrpadd(1).
4097
tpaclcvt(1) encountered an error when attempting to add a group. The error_string can help to determine exactly what error occurred.
4098
INFO: Line number Group groupname not added. Error retrieving error.
tpaclcvt(1) encountered an error when adding a group to the T_ACLGROUP class. When attempting to retrieve the error from the returned FML32 buffer, an error occurred.
If this error occurs consistently, contact BEA TUXEDO system Technical Support.
4099
INFO: Line number Group groupname: error_string
tpaclcvt(1) received the given error_string from the MIB when adding the group on the given line.
Use the error_string returned from the MIB to determine exactly what error occurred.