1 |
ERROR: Memory allocation failure | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. An attempt to allocate memory for semaphore list from the operating system using |
Action |
Reduce the memory usage on the machine or increase the amount of physical memory on the machine. | |
2 |
ERROR: Cannot open semaphore 'name': error | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
3 |
ERROR: Cannot wakeup proc pid: error | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
4 |
ERROR: Cannot access ipc server (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
5 |
ERROR: Cannot access server pipe (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
6 |
ERROR: Cannot set pipe state (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
7 |
ERROR: Cannot contact ipc server (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
This function fails if the server did not create the pipe as a message-type pipe or if the pipe handle is not in message-read mode. Also, the function returns ERROR_MORE_DATA if the read buffer specified in the call is not large enough to hold the entire message. The extended error information is described in error by calling | |
8 |
ERROR: Invalid reply length from server (read/reply) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The reply buffer from the BEA TUXEDO system IPC Server has invalid length after the |
Action |
Please check Microsoft documentation for details on | |
9 |
WARN: Reusing existing shared memory segment 'IPCSEG' | |
|
Description |
Existing shared memory segment will be reused. |
Action |
No action required. | |
10 |
WARN: Existing parameter value = configuration, cannot change to actual | |
|
Description |
When creating BEA TUXEDO system IPC, warning messages are issued if existing values do not match with default configuration values for all parameters of the BEA TUXEDO system IPC Helper service. |
Action |
Check your registry database for all your BEA TUXEDO system IPC parameters. | |
11 |
ERROR: Memory allocation failure | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. An attempt to allocate memory for an anonymous security descriptor from the operating system using |
Action |
Reduce the memory usage on the machine or increase the amount of physical memory on the machine. | |
12 |
ERROR: Cannot initialize security descriptor (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
13 |
ERROR: Cannot set ACL to security descriptor (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
14 |
ERROR: Cannot create IPC mutex (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
15 |
ERROR: Cannot create shared memory 'IPCSEG' (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
16 |
ERROR: Cannot access Service Manager (error) | |
|
Description |
The |
Action |
The extended error information is described in error by calling | |
17 |
ERROR: Cannot access service 'process' (error) | |
|
Description |
The |
Action |
This error occurs usually because the BEA TUXEDO system IPC Helper service does not exist. You need to initially run the setup program comes with the BEA TUXEDO system distribution media to install the software. As part of the installation, the BEA TUXEDO system IPC Helper service will be created. Restart the BEA TUXEDO IPC Helper service. The extended error information is described in error by calling | |
18 |
ERROR: Cannot start service 'process' (error) | |
|
Description |
The |
Action |
This error occurs usually because the BEA TUXEDO system IPC Helper service does not exist. You need to initially run the setup program comes with the BEA TUXEDO system distribution media to install the software. As part of the installation, the BEA TUXEDO system IPC Helper service will be created. It is possible that the BEA TUXEDO system IPC Helper service binary (tuxipc.exe) could not be found. Check your path and registry values under \HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\BEA TUXEDO system IPC Helper\ImagePath. It is also possible that another instance of the BEA TUXEDO system IPC Helper is already running. Other possible errors are the service database is locked or the BEA TUXEDO system IPC Helper service has been disabled. Restart your BEA TUXEDO system IPC Helper service. The extended error information is described in error by calling | |
19 |
ERROR: Cannot query service 'process' (error) | |
|
Description |
The |
Action |
The extended error information is described in error by calling | |
20 |
WARN: Service 'TUXEDO IPC Helper' could not be started | |
|
Description |
The BEA TUXEDO system IPC Helper service could not be started because Windows NT service manager could not be opened or the BEA TUXEDO system IPC Helper service is inaccessible. The BEA TUXEDO system IPC Helper (tuxipc.exe) will be started as a normal process rather than a service now. |
Action |
No action required. | |
21 |
WARN: All applications will exit when console user logs off | |
|
Description |
The BEA TUXEDO system IPC Helper (tuxipc.exe) is started as a normal process rather than a service. All applications will exit when console user logs off. |
Action |
No action required. | |
22 |
ERROR: Cannot create ipc server process 'tuxipc.exe' (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
23 |
ERROR: Cannot create sleep semaphore 'name' (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
24 |
ERROR: Cannot access ipc server pipe 'IPC_SERVER_PIPE' (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
25 |
WARN: Reopening existing segment 'shmid' | |
|
Description |
Unable to get a BEA TUXEDO system shared memory segment. The |
Action |
No action required. | |
26 |
ERROR: shmat: Missing segment 'shmid' | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. Unable to attach a BEA TUXEDO system shared memory segment. The |
Action |
Restart your BEA TUXEDO system IPC Helper service or reboot your machine if the problem is persistent. | |
27 |
WARN: shmdt: Cannot unmap segment | |
|
Description |
Unable to detach a BEA TUXEDO system shared memory segment. The |
Action |
Contact BEA Customer Support. | |
28 |
ERROR: Cannot release semaphore (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
29 |
ERROR: Cannot create timer event (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
31 |
ERROR: Cannot create pause event (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
32 |
ERROR: Cannot create timer start event (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
33 |
ERROR: Cannot create timer thread (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
34 |
ERROR: Cannot wait on start event (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
35 |
ERROR: Cannot send message to timer thread threadId (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
39 |
ERROR: Memory allocation error (line line_number) | |
|
Description |
An attempt to allocate memory from the operating system using |
Action |
Reduce the memory usage on the machine or increase the amount of physical memory on the machine. | |
40 |
ERROR: Cannot create watchdog start event (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
41 |
ERROR: Cannot create watchdog thread (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
42 |
ERROR: Removing invalid process pid | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. Process pid is no longer alive, and it will be removed. |
Action |
Contact BEA Customer Support. | |
43 |
ERROR: Watchdog wait failed (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. Waiting for the process to terminate has failed. |
Action |
The extended error information is described in error by calling | |
44 |
ERROR: Cannot create new process event (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
45 |
ERROR: Cannot create ipc data (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. Creating the BEA TUXEDO system IPC data has failed. |
Action |
The extended error information is described in error by calling | |
46 |
ERROR: Cannot create server pipe 'IPC_SERVER_PIPE' (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
47 |
ERROR: Pipe connect failed (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
48 |
ERROR: Cannot read pipe (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
49 |
ERROR: Unexpected read size read/ipcop | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
Contact BEA Customer Support. | |
50 |
ERROR: Unexpected request action | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. Invalid IPC request was given to the BEA TUXEDO system IPC Helper. |
Action |
Contact BEA Customer Support. | |
51 |
ERROR: Cannot write to pipe (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
52 |
ERROR: Unexpected write size write/reply | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
Contact BEA Customer Support. | |
53 |
ERROR: Cannot flush pipe (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
54 |
WARN: Cannot disconnect pipe (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
55 |
ERROR: Cannot start IPC services (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
56 |
ERROR: Cannot set service status (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
57 |
ERROR: Cannot create worker thread (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
58 |
INFO: IPC server exiting | |
|
Description |
The BEA TUXEDO system IPC Helper server is exiting. |
Action |
No action required. | |
59 |
ERROR: Cannot start process in background mode, cmdline=val, errno=val2 | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. An attempt to start the current process in background mode failed. |
Action |
The extended error information is described in error by calling | |
60 |
ERROR: Memory allocation failure | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. An attempt to allocate memory from the operating system using |
Action |
Reduce the memory usage on the machine or increase the amount of physical memory on the machine. | |
61 |
ERROR: Could not make pipe, errno=error | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
62 |
ERROR: Could not fork, errno=error | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
63 |
ERROR: Child dup error, rc=retcode, errno=error | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The _open_osfhandle system function call failed. |
Action |
The extended error information is described in error by calling | |
64 |
ERROR: Parent dup error while saving stdout, errno=error | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The _dup system function call failed. |
Action |
The extended error information is described in error by calling | |
65 |
WARN: pager: wait status 0xstatus, errno=error | |
|
Description |
The |
Action |
The extended error information is described in error by calling | |
66 |
ERROR: Cannot create process (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
67 |
ERROR: Could not allocate thread local storage, error number = error | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
68 |
ERROR: Could not allocate thread local storage, error number = error | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling | |
71 |
ERROR: Memory allocation failure | |
|
Description |
An attempt to allocate memory from the operating system using |
Action |
Reduce the memory usage on the machine or increase the amount of physical memory on the machine. | |
72 |
ERROR: TUXDIR environment variable not set | |
|
Description |
The BEA TUXEDO system environment variable |
Action |
Set the environment variable | |
See Also |
BEA TUXEDO system Installation Guide | |
73 |
ERROR: Memory allocation failure | |
|
Description |
An attempt to allocate memory from the operating system for buildclient failed. |
Action |
Reduce the memory usage on the machine or increase the amount of physical memory on the machine. | |
74 |
ERROR: Unused arguments passed to command | |
|
Description |
Extra arguments were given to the buildclient command for building BEA TUXEDO system clients. |
Action |
Consult your BEA TUXEDO system documentation for valid arguments for | |
See Also |
| |
75 |
ERROR: Memory allocation failure | |
|
Description |
An attempt to allocate memory from the operating system using |
Action |
Reduce the memory usage on the machine or increase the amount of physical memory on the machine. | |
76 |
ERROR: Can't open tempfile filename | |
|
Description |
An attempt to open a temporary file using fopen failed. |
Action |
Check the permissions of the file and repeat the operation. | |
See Also |
fopen | |
77 |
ERROR: Can't execute cc_cmd | |
|
Description |
The buildclient command was unable to execute the C compiler command. The C compiler command that buildclient attempted to execute is given as part of this error message. |
Action |
Verify that the Microsoft Visual C++ compiler has been installed on the machine, that it is executable, and that the directory containing the compiler is included in your PATH environment variable. | |
See Also |
buildclient(1) | |
78 |
ERROR: Can't execute cc_cmd | |
|
Description |
The buildclient command was unable to execute the C compiler command. The C compiler command that buildclient attempted to execute is given as part of this error message. |
Action |
Verify that the Microsoft Visual C++ compiler has been installed on the machine, that it is executable, and that the directory containing the compiler is included in your PATH environment variable. | |
See Also |
buildclient(1) | |
94 |
ERROR: Cannot open registry key | |
|
Description |
Unable to open the registry key for the BEA TUXEDO system Performance Monitor: \\HKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\TUXEDO IPC Helper\\Performance. The |
Action |
This error occurs usually because the registry key for the BEA TUXEDO system IPC Helper service does not exist or it was not created properly. You need to initially run the setup program comes with the BEA TUXEDO system distribution media to install the software. As part of the installation, the BEA TUXEDO system IPC Helper service will be created as well as the registry keys. Other possible errors are your registry database somehow got locked. You might need to reboot the machine if the problem is persistent. | |
95 |
ERROR: Cannot obtain 'First Counter' data | |
|
Description |
Unable to retrieve the "First Counter" data from the registry for the BEA TUXEDO system Performance Monitor: \\HKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\TUXEDO IPC Helper\\Performance. The |
Action |
This error occurs usually because the registry key for the BEA TUXEDO system IPC Helper service does not exist or it was not created properly. You need to initially run the setup program comes with the BEA TUXEDO system distribution media to install the software. As part of the installation, the BEA TUXEDO system IPC Helper service will be created as well as the registry keys. Other possible errors are your registry database somehow got locked. You might need to reboot the machine if the problem is persistent. | |
96 |
ERROR: Cannot obtain 'First Help' data | |
|
Description |
Unable to retrieve the "First Help" data from the registry for the BEA TUXEDO system Performance Monitor: \\HKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\TUXEDO IPC Helper\\Performance. The |
Action |
This error occurs usually because the registry key for the BEA TUXEDO system IPC Helper service does not exist or it was not created properly. You need to initially run the setup program comes with the BEA TUXEDO system distribution media to install the software. As part of the installation, the BEA TUXEDO system IPC Helper service will be created as well as the registry keys. Other possible errors are your registry database somehow got locked. You might need to reboot the machine if the problem is persistent. | |
99 |
ERROR: Cannot create process maintenance thread (error) | |
|
Description |
An internal BEA TUXEDO system IPC error has occurred. The |
Action |
The extended error information is described in error by calling |
|