BEA Logo BEA Banner

  Corporate Info  |  News  |  Solutions  |  Products  |  Partners  |  Services  |  Events  |  Download  |  How To Buy

 

   WLE Doc Home   |   Messages   |   Catalog List   |   Previous   |   Next


ISNAT Messages 1400-1499



1400


ERROR: Cannot create pipe for listener

Description

Solaris only. The IIOP Server Handler creates a pipe to communicate with an IIOP Server Listener. The pipe cannot be created.

Action

Make sure the operating system has enough resources to create pipes.


1401


ERROR: Cannot setup pipe for listener

Description

Solaris only. The IIOP Server Handler sets up a pipe to communicate with an IIOP Server Listener. The setup operation failed.

Action

Contact BEA Customer Support.


1402


ERROR: Cannot attach to pipe for listener

Description

Solaris only. The IIOP Server Handler attaches a named pipe to a normal pipe to communicate with an IIOP Server Handler. The attach operation failed.

Action

Contact BEA Customer Support.


1403


ERROR: Cannot create UNIX socket

Description

HP-UX, AIX, and Tru64 UNIX only. The IIOP Server Listener failed to create a UNIX socket to communicate with an IIOP Server Handler.

Action

Make sure the operating system parameters are set correctly to handle UNIX sockets.


1404


ERROR: Cannot bind to UNIX socket

Description

HP-UX, AIX, and Tru64 UNIX only. The IIOP Server Handler creates a UNIX socket to communicate with an IIOP Server Listener. The file for the UNIX socket cannot be created.

Action

Shut the listener down, remove all files with names that begin with ISH.pipe from the APPDIR directory and reboot the IIOP Server Listener/Handler. If the problem persists, contact BEA Customer Support.


1405


ERROR: Cannot listen on UNIX socket

Description

HP-UX, AIX, and Tru64 UNIX only. The IIOP Server Handler creates a UNIX socket to communicate with an IIOP Server Listener. The IIOP Server Listener/Handler cannot set up the length of the listen queue.

Action

Make sure the operating system parameters are set correctly to handle UNIX sockets.


1406


ERROR: Missing protocol machine information

Description

An internal error occurred in the IIOP Server Listener/Handler.

Action

Contact BEA Customer Support.


1407


ERROR: Missing protocol machine information

Description

An internal error occurred in the IIOP Server Listener/Handler.

Action

Contact BEA Customer Support.


1408


ERROR: Missing protocol machine information

Description

An internal error occurred in the IIOP Server Listener/Handler. [Action] Contact BEA Customer Support.


1409


ERROR: Missing protocol machine information

Description

An internal error occurred in the IIOP Server Listener/Handler.

Action

Contact BEA Customer Support.


1410


ERROR: No : separator in network address

Description

The IIOP Server Handler process was invoked with an ISL command that specified an incorrect network address. The ISL command network address (netaddr) argument to the -n option must be of the form //host:port. This error indicates that the colon is missing in the argument.

Action

Fix the application configuration for the IIOP Server Listener/Handler and make sure the network address has the appropriate syntax.


1411


ERROR: No memory for host variable

Description

The IIOP Server Listener/Handler failed to allocate memory for an internal structure.

Action

Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.


1412


ERROR: Cannot register protocols

Description

While initializing the IIOP Server Listener (ISL), an internal error occurred.

Action

Check the ULOG for other error messages that may indicate the exact nature of the problem and reason for this failure.


1413


ERROR: Hex address type not supported

Description

The network address argument to option -n of the IIOP Server Listener/Handler uses the WLE hexadecimal format 0x0002. The IIOP Server Listener/Handler expects the network address argument to be of the form //host:port.

Action

Fix the application configuration for the IIOP Server Listener/Handler and make sure the network address has the appropriate format.


1415


WARN: Received a non-GIOP message

Description

The IIOP Server Listener/Handler received a non-GIOP message. This can occur when a client application other than an WLE remote client application attempts to connect to the IIOP Server Listener/Handler; for example, a JOLT client application, an ATMI client application, or an http client application. After this message is written to the ULOG, the IIOP Server Listener/Handler closes the connection with the client application.

Action

Make sure that only WLE remote client applications connect to the IIOP Server Listener/Handler.


1416


INFO: Ignoring non-request type messages

Description

The IIOP Server Listener/Handler does not process messages that do not relate to requests or replies.

Action

None.


1417


ERROR: message blocked, one-way method not executed

Description

There is already a message waiting for this client. Since this one-way method does not return values, this request is being dropped.

Action

Wait for the connection to free up and try again.


1419


ERROR: Invalid command line argument 'val' ignored

Description

An illegal command-line option was found in the command-line options for the IIOP Server Handler. This error is rare because the IIOP Server Listener, not the system administrator, starts the IIOP Server Handler.

Action

Contact BEA Customer Support.

See Also

For information aboutISL command, see Administration in the WebLogic Enterprise online documentation and, in particular, the discussion of the CLOPT parameter.


1420


ERROR: Expected numeric argument to -s option

Description

An invalid argument was passed to the ISL command-line option. The argument to the -s option, the server timeout, needs to be numeric. This error causes the IIOP Server Listener not to be booted.

Action

Make sure the argument to the -s option is numeric.

See Also

The ISL command. For information about the ISL command, see the Administration Guide.


1421


ERROR: Expected numeric argument to -u option

Description

An invalid argument was passed to the ISL command-line option. The argument to the -u option, the number of outbound IIOP users, needs to be numeric. This error causes the IIOP Server Listener not to be booted.

Action

Make sure the argument to the -u option is numeric.

See Also

The ISL command. For information about the ISL command, see the Administration Guide.


1422


ERROR: Bad -u option

Description

The IIOP Server Listener process was invoked with a -u option that specified an option argument outside the allowed range. The -u option specifies the number of outbound IIOP users (native clients or servers) that can be supported simultaneously by each outbound IIOP connection. This option must be greater than 0 but not more than 1024.

Action

Make sure the argument to the -u option is between 1 and 1024.

See Also

The ISL command. For information about the ISL command, see the Administration Guide.


1423


ERROR: Expected numeric argument to -o option

Description

An invalid argument was passed to the ISL command-line option. The argument to the -o option, the maximum number of outbound connections, needs to be numeric. This error causes the IIOP Server Listener not to be booted.

Action

Make sure the argument to the -o option is numeric.

See Also

The ISL command. For information about the ISL command, see the Administration Guide.


1424


INFO: host = "host_name", port = port_number

Description

The IIOP Server Listener is listening on this host and port.

Action

None.


1425


ERROR: Bad -o option

Description

The IIOP Server Listener process was invoked with an -o option that specified an option argument outside the allowed range. The -o option specifies the maximum number of outbound connections that each ISH may have. This option must be greater than zero but not more than 4096. In addition, the -o option times the maximum number of handlers must be less than 32767.

Action

Make sure the argument to the -o option is between 1 and 4096, and that the -M option multiplied by the -o option is less than 32767.

See Also

The ISL command. For information about the ISL command, see the Administration Guide.


1426


ERROR: -O option must be specified if -o, -s, or -u specified

Description

The IIOP Server Listener process was not invoked with the -O option, enable outbound IIOP, when the -o, -s, or -u options were specified. Since the -O option requires a small amount of extra resources, outbound IIOP is not enabled by default.

Action

Add the -O option to the ISL command.

See Also

The ISL command. For information about the ISL command, see the Administration Guide.


1427


ERROR: Error initializing OCM table

Description

The IIOP Server Listener could not initialize the data structures used for asymmetric outbound IIOP.

Action

The error indicates an internal problem with the IIOP Server Listener. Contact BEA WLE Technical Support.


1428


WARN: No space in ISL shared memory for additional OCM entries

Description

The maximum number of outbound IIOP connections, determined by the ISL -o option multiplied by the -M option, has been reached.

Action

Raise the maximum number of outbound IIOP connections or add IIOP Server Listeners.

See Also

The ISL command. For information about the ISL command, see the Administration Guide.


1429


ERROR: Cannot advertise service_name, tperrno = errno

Description

The IIOP Server Listener could not advertise the service used for asymmetric outbound IIOP.

Action

The error indicates an internal problem with the IIOP Server Listener. Contact BEA WLE Technical Support.


1430


ERROR: Cannot unadvertise service_name, tperrno = errno

Description

The IIOP Server Listener could not unadvertise the service used for asymmetric outbound IIOP.

Action

The error indicates an internal problem with the IIOP Server Listener. Contact BEA WLE Technical Support.


1431


ERROR: Invalid arguments, field id field_id not passed

Description

Invalid arguments were passed to the IIOP Server Listener.

Action

The error indicates an internal problem with the IIOP Server Listener. Contact BEA WLE Technical Support.


1432


ERROR: Invalid connection id id

Description

An invalid connection id was passed to the IIOP Server Listener.

Action

The error indicates an internal problem with the IIOP Server Listener. Contact BEA WLE Technical Support.


1433


ERROR: Error binding outbound connection request, can't create any more handlers

Description

The IIOP Server Listener could not start another IIOP Server Handler to process the outbound request.

Action

Raise the maximum number of IIOP Server Handlers (ISL -M option).


1434


ERROR: OCM entry could not be added

Description

The outbound IIOP connection could not be added to the outbound connection map because the IIOP Server Listener could not start another IIOP Server Handler.

Action

Raise the maximum number of IIOP Server Handlers (ISL -M option).


1435


INFO: external host = "host_name", port = port_number

Description

The IIOP Server Listener stores this host and port in any object references returned to the client. The host and port are determined by the -H option.

Action

None.


1436


ERROR: Could not timeout OCM entry

Description

An error occurred while timing out an outbound IIOP connection.

Action

The error indicates an internal problem with the IIOP Server Listener. Contact BEA Customer Support.


1437


INFO: Host: [host_name], Port: [port_number] connection timed out due to inactivity

Description

The IIOP Server Listener has determined that the outbound connection has not been used within the server timeout period (ISL -s option). The connection will be torn down by the IIOP Server Handler.

Action

None. If a subsequent request is received for this connection, the connection will be reestablished.


1438


ERROR: Sending of request message to server failed

Description

While a request message was being sent to a remote server application, the operation failed.

Action

Check the ULOG for messages indicating the nature of the failure. This warning may indicate that the remote server application is no longer accessible (that is, either the network or machine has failed). Contact BEA Customer Support.


1439


ERROR: Missing outbound connection

Description

The IIOP Server Handler does not have the necessary outbound connection information to send the request.

Action

The error indicates an internal problem with the IIOP Server Handler. Contact BEA Customer Support.


1440


ERROR: Could not connect to host/port host_port_address

Description

The IIOP Server Handler could not connect to the host and port contained within the object reference.

Action

Determine if the remote machine has failed.


1441


INFO: No outstanding request to send reply

Description

A reply has been received from the remote server application. There is no corresponding entry on the outstanding request queue. The remote server may have exceeded the timeout period for the request and the entry has already been removed from the queue.

Action

Determine if the remote server is processing invocations within the timeout period. Determine if the timeout period is appropriate for your application (BLOCKTIME multiplied by SCANUNIT).


1442


ERROR: Could not add message to blocked queue

Description

The IIOP Server Handler could not add the reply from the remote server application on the queue of blocked messages.

Action

Examine the ULOG for any immediately preceding messages giving further information about the cause of the error. Contact BEA Customer Support.


1443


ERROR: Cannot send reply to caller: error_text

Description

The IIOP Server Handler could not send the reply from the remote server application back to the caller (native client or server).

Action

Examine the ULOG for any immediately preceding messages giving further information about the cause of the error. Contact BEA Customer Support.


1444


ERROR: Invalid outbound IIOP request

Description

The IIOP Server Handler received a message without the necessary request information.

Action

The error indicates an internal problem with the IIOP Server Handler. Contact BEA Customer Support.


1445


INFO: Outbound connection index timed out due to inactivity

Description

The outbound connection was not used within the server timeout period (ISL -s option). The connection has been torn down.

Action

None. If a subsequent request is received for this connection, the connection will be reestablished.


1446


ERROR: Cannot send oneway reply

Description

The IIOP Server Handler could not send a oneway reply to the remote server application.

Action

This warning may indicate that the remote server application is no longer accessible (that is, either the network or machine has failed). Contact BEA Customer Support.


1447


ERROR: Cannot decode fragment header

Description

The IIOP Server Handler could not decode a fragment header.

Action

The error indicates an internal problem with the IIOP Server Handler. Contact BEA Customer Support.


1448


ERROR: Cannot copy msg to call buffer

Description

The IIOP Server Handler could not copy a message to an internal buffer.

Action

The error indicates an internal problem with the IIOP Server Handler. Contact BEA Customer Support.


1451


ERROR: Invalid socket index index

Description

The IIOP Server Handler received a message with an invalid socket index.

Action

The error indicates an internal problem with the IIOP Server Handler. Contact BEA Customer Support.


1452


ERROR: Invalid -s option = value

Description

The IIOP Server Listener process was invoked with an -s option that specified an option argument outside the allowed range. The -s option specifies the server timeout in minutes. This option must be greater than 0.

Action

Make sure the argument to the -s option is greater than 0.

See Also

The ISL command. For information about the ISL command, see the Administration Guide.


1453


INFO: Attempting to forward bind to another ISL

Description

If the maximum number of outbound IIOP connections, determined by the -o option multiplied by the -M option, is reached, the IIOP Server Listener attempts to forward the request to a different IIOP Server Listener.

Action

If the forward is successful, no action is required. If the forward fails, either raise the maximum number of outbound IIOP connections or add IIOP Server Listeners.


1454


ERROR: Cannot set performance log directory

Description

The IIOP Server Listener was unable to construct a performance log filename.

Action

None.


1456


ERROR: Could not get performance log information

Description

The IIOP Server Listener was unable to record performance data.

Action

None.


1457


ERROR: val performance log file open error

Description

The IIOP Server Listener was unable to open a file in which to record performance data.

Action

None.


1458


ERROR: Write error val, file val

Description

The IIOP Server Listener was unable to write performance data to the performance log file.

Action

None.


1460


WARN: Received a non-SSL message

Description

The IIOP Server Listener received a non-SSL message on the secure port.

Action

Verify that the client is using SSL. If using the WLE Bootstrap object, the client should specify the corbalocs://host:port format.


1461


ERROR: Memory allocation failure

Description

An attempt to allocate memory dynamically from the operating system using malloc failed.

Action

Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Either reduce the memory usage on the machine or increase the amount of physical memory on the machine. Also, increase the space on the swap device.

See Also

See the malloc function.

For UNIX systems, see the malloc(3) manual page.

For Microsoft Windows NT systems, see the Microsoft Visual C++ online help.


1462


ERROR: The -z (val) must be 0, 40, 56, or 128

Description

The -z value must be one of the listed values.

Action

Change the value to one of the listed values.

See Also

For information about the ISL command, see Administration in the WebLogic Enterprise online documentation.


1463


ERROR: The -Z (val) must be 0, 40, 56, or 128

Description

The -Z value must be one of the listed values.

Action

Change the value to one of the listed values.

See Also

For information about the ISL command, see Administration in the WebLogic Enterprise online documentation.


1464


ERROR: SSL package is not installed

Description

The IIOP Server Listener was started with SSL options specified, but the SSL package is not installed.

Action

Either install the SSL package, or reconfigure the Listener not to use SSL.

See Also

For information about the ISL command, see Administration in the WebLogic Enterprise online documentation.


1465


ERROR: Only exportable encryption is allowed

Description

The values specified for the -Z or -z option were greater than that allowed for this SSL installation.

Action

Verify the -Z and -z option values are not greater than the encryption strength of the installed SSL package.

See Also

For information about the ISL command, see Administration in the WebLogic Enterprise online documentation.


1466


ERROR: -z option is greater than -Z option

Description

The -z option must be smaller or equal to the -Z option.

Action

Change the -z and -Z options so the -z option is less than or equal to the -Z option.

See Also

For information about ISL command, see Administration in the WebLogic Enterprise online documentation.


1467


ERROR: Could not get listening socket information

Description

An error has occurred when getting the listening socket information for an SSL connection.

Action

Contact BEA Customer Support.


1468


ERROR: Invalid state for SSL connection val

Description

The SSL connection 'val' has an invalid state.

Action

Contact BEA Customer Support.


1469


ERROR: Could not write to SSL connection, err = val

Description

An error 'val' occurred while trying to write to the SSL connection. This may occur due to errors in the SSL handshake or transport errors on the socket.

Action

The ULOG may give more information about the error.


1470


ERROR: Could not create SSL context on connect

Description

The IIOP Server Listener was unable to create the SSL context.

Action

The ULOG may give more information about the error.


1471


ERROR: Could not set SSL protocol to client side, err = val

Description

The IIOP Server Listener was unable to set the SSL protocol due to the error 'val'.

Action

The ULOG may give more information about the error.


1472


ERROR: Invalid ASN encoding

Description

An internal error occurred while processing an ASN encoded object.

Action

The ULOG may give more information about the error. Contact BEA Customer Support.


1473


ERROR: Could not create SSL context on accept

Description

The IIOP Server Listener was unable to create the SSL context.

Action

The ULOG may give more information about the error. Contact BEA Customer Support.


1474


ERROR: Could not set SSL protocol to server side, err = val

Description

The IIOP Server Listener was unable to set the SSL protocol due to the error 'val'.

Action

The ULOG may give more information about the error.


1475


ERROR: ASN integer too big

Description

A data field of the ASN encoded object contains an integer too big for the platform.

Action

Contact BEA Customer Support.


1476


INFO: SSL function completed successfully

Description

The SSL function was successful.

Action

None.


1477


ERROR: SSL function was called with an invalid parameter

Description

The IIOP Server Handler encountered an internal error when passing a parameter.

Action

Contact BEA Customer Support.


1478


ERROR: call failed because the SSL Connection has already been closed due to an error

Description

The IIOP Server Handler encountered an internal error.

Action

Contact BEA Customer Support.


1479


WARN: SSL connection is closed, but closed in a graceful manner

Description

The IIOP Server Handler's SSL connection closed, but data integrity was preserved.

Action

None.


1480


ERROR: SSL fatal alert was received

Description

The IIOP Server Handler encountered a fatal SSL error.

Action

Contact BEA Customer Support.


1481


ERROR: SSL connection closed without check for graceful close message

Description

The IIOP Server Listener/Handler's SSL connection closed without verification.

Action

None.


1482


ERROR: fatal IO error on SSL connection

Description

An unexpected fatal error occurred on the IIOP Server Handler's SSL connection.

Action

Contact BEA Customer Support.


1483


ERROR: SSL memory allocation function failed

Description

An attempt to allocate memory dynamically from the operating system using malloc failed.

Action

Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Either reduce the memory usage on the machine or increase the amount of physical memory on the machine. Increase the space on the swap device.

See Also

See the malloc function.

For UNIX systems, see the malloc(3) manual page.

For Microsoft Windows NT systems, see the Microsoft Visual C++ online help.


1484


ERROR: SSL secure connection could not be negotiated

Description

A secure connection could not be negotiated. This may occur due to encryption strength differences, certificate validation errors, or initialization failures.

Action

The ULOG may give more information about the error. Verify that the client encryption strength (-ORBminCrypto, -ORBmaxCrypto) is within the range supported by the IIOP Server Listener (-z, -Z).


1485


ERROR: SSL index out of range

Description

An internal error has occurred.

Action

Contact BEA Customer Support.


1486


ERROR: SSL protocol violation occurred

Description

There was a violation of the SSL protocol.

Action

Contact BEA Customer Support.


1487


ERROR: Unknown SSL error

Description

An unknown SSL error has occurred.

Action

Contact BEA Customer Support.


1488


ERROR: SSL session record could not be located

Description

The IIOP Server Listener could not locate the SSL session record.

Action

This indicates an internal error. Contact BEA Customer Support.


1489


ERROR: SSL feature or value not supported

Description

An SSL feature or value that is not supported has been specified.

Action

Contact BEA Customer Support.

See Also

For information about ISL command, see Administration or Using Security in the WebLogic Enterprise online documentation.


1490


INFO: SSL connection would block

Description

The IIOP Server Handler has encountered a situation where it would block if it attempts to read the SSL connection.

Action

Contact BEA Customer Support.


1491


ERROR: Could not get admin key, errno = val

Description

The IIOP Server Handler encountered the error 'val' when attempting to get the admin key.

Action

Contact BEA Customer Support.


1492


ERROR: X.509 certificate chain could not be completed with a self-signed root certificate

Description

The IIOP Server Handler was unable to verify the SSL certification chain without a self-signed root certificate.

Action

Verify that the certificate chain contains a self-signed root certificate.


1493


ERROR: X.509 certificate chain is invalid for some reason

Description

The IIOP Server Handler encountered an invalid X.509 certificate chain.

Action

Verify the certificate chain.


1494


ERROR: Could not init decrypt of admin key, errno = val

Description

The IIOP Server Handler could not initialize the decryption of the administration key because of the error 'val'.

Action

Contact BEA Customer Support.


1495


ERROR: One of the X.509 certificates in the chain has expired or that is not yet valid

Description

The IIOP Server Handler encountered an X.509 certification that has expired or is not yet valid.

Action

Verify the certificate chain.


1496


ERROR: X.509 certificate data extraction function failed to find the requested data

Description

The IIOP Server Handler was unable to find the requested data in the certificate.

Action

Verify the certificate. Contact BEA Customer Support.


1497


ERROR: X.509 names are not equal

Description

The X.509 names contained within two SSL certificates are not equal.

Action

Verify the certificates. Contact BEA Customer Support.


1498


ERROR: SSL file was not found

Description

An SSL file was not found.

Action

Contact BEA Customer Support.


1499


ERROR: SSL data was not found

Description

SSL data was not found.

Action

Verify the filename and directory of the private keys, the public keys, the certification rules files, and the LDAP files.

See Also

See Administration or Using Security in the WebLogic Enterprise online documentation.