2813


ERROR: Unable to open snapshot file

Description

The snapshot file of the log tool could not be opened.

Action

Check the permission of the snapshot directory. Make sure you have read and write privileges.


2824


ERROR: ULOG got unknown message: message

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2850


ERROR: fatal, security argument is invalid: -z value

Description

The encryption level specified in the BEA TUXEDO WEB GUI initialization file is invalid. The valid levels are 0, and 40.

Action

Enter a valid encryption level.


2851


ERROR: Could not open logfile: filename

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2852


INFO: wgated starting

Description

The BEA TUXEDO WEB GUI process named wgated has started. You will see this message when the applet first appears. You will also see this message when you invoke the activate, deactivate, or migrate tools.

Action

No action is required.


2853


ERROR: TUXDIR not set in initialization file

Description

The ini file requires the TUXDIR entry. For more information, consult the documentation for wlisten.

Action

Specify the TUXDIR in the ini file.


2854


ERROR: Could not open ini file

Description

The BEA TUXEDO WEB GUI initialization file could not be opened.

Action

Check the permission of the file. Make sure you have read and write privileges.


2855


ERROR: wgated could not initialize the network

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2856


ERROR: wgated Cannot convert network file descriptor, error code is: strerror

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2857


ERROR: wgated could not perform network synch on file descriptor

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2858


ERROR: wgated Fatal error, authentication or encryption is turned on, but security package is not installed.

Description

Missing BEA TUXEDO security package.

Action

Install BEA TUXEDO security package.


2859


ERROR: wgated fatal error, encryption is turned on, but requires authentication which is turned off.

Description

Encryption requires authentication to be turned on.

Action

Enable authentication. For more information, consult the documentation for tlisten authentication.


2860


INFO: wgated challenge response does not match any password value

Description

The password entry is invalid.

Action

Re-enter a valid password.


2866


ERROR: wgated received unknown message: 'message'

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2867


ERROR: wgated received message with no addressee, skipping message

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2868


ERROR: wgated received a message with an unknown subsystem: value

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2869


ERROR: wgated network error on receive

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2871


ERROR: wgated network error on receive

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2872


ERROR: wgated receive_one_line buffer overflowed

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2873


ERROR: wgated send_one_line failed while sending

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2874


ERROR: Failed to change working directory to "APPDIR" (errno = number)

Description

The APPDIR directory is inaccessible.

Action

Check the permission of the directory. Make sure you have read and write privileges.


2875


ERROR: Failed to determine file length for "filename" (errno = number)

Description

The password file is inaccessible.

Action

Check the permission of the file. Make sure you have read and write privileges. For more information, consult the documentation for tlisten authentication.


2876


ERROR: Authentication requested, but no password file exists

Description

The password file is inaccessible.

Action

Check the permission of the file. Make sure you have read and write privileges. For more information, consult the documentation for tlisten authentication.


2877


INFO: W L I S T E N A U T H E N T I C A T I O N I S D I S A B L E D !

Description

You have purposely or accidently configured the BEA TUXEDO WEB GUI to disable password validation.

Action

No action is required.


2878


ERROR: Password file "filename" exists, encryption is not available

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2879


ERROR: Failed to open password file "filename" (errno = number)

Description

The password file is inaccessible.

Action

Check the permission of the file. Make sure you have read and write privileges. For more information, consult the documentation for tlisten authentication.


2880


ERROR: Cannot read password file "filename" (errno=number)

Description

The password file is inaccessible.

Action

Check the permission of the file. Make sure you have read and write privileges. For more information, consult the documentation for tlisten authentication.


2881


ERROR: wgated could not open password file, fatal error

Description

The password file is inaccessible.

Action

Check the permission of the file. Make sure you have read and write privileges. For more information, consult the documentation for tlisten authentication.


2882


WARN: wgated found too many passwords in file, only looking at first number

Description

There are too many entries in the password file. Entries beyond the limit are ignored.

Action

Reduce the number of password entries.


2883


ERROR: wgated found no passwords in the password file. (Fatal error.)

Description

The password file has no entries.

Action

Add an entry to the password file. For more information, consult the documentation for tlisten authentication.


2884


WARN: wgated was unable to tppwtokey on password number number in tlisten password file

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2885


ERROR: wgated was unable to cryptinit with password number number in tlisten password file

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2886


ERROR: wgated was unable to encrypt challenge response with password number number in tlisten password file

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2887


ERROR: Failure getting job descriptor information Error = value

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2888


ERROR: Failure getting socket from parent process, error code is strerror

Description

BEA TUXEDO WEB GUI internal error.

Action

Contact your BEA TUXEDO system Technical Support.


2889


WARN: guimib_tpterm failed,tperrno = error

Description

The GUI was unable to do a tpterm(3c) from the application. Look at surrounding entries in the ULOG to determine the cause of the tpterm(3c) failure. This is a non-critical, internal error in the GUI and will not affect the GUI's functionality or performance.

Action

No action is needed.

See Also

tpterm(3c)


2890


WARN: unknown protocol received

Description

The GUI's server side received an unknown message from the JAVA front-end of the GUI. This is an internal error in the wgated process and may or may not affect the GUI's functionality or performance.

Action

Contact your BEA TUXEDO system Technical Support and provide a description of the action being performed when this error was seen.

See Also

tpterm(3c)


2891


WARN: guimib_tpterm failed,tperrno = error

Description

The GUI was unable to do a tpterm(3c) from the application. Look at surrounding entries in the ULOG to determine the cause of the tpterm(3c) failure. This is a non-critical, internal error in the GUI and will not affect the GUI's functionality or performance.

Action

No action is needed.

See Also

tpterm(3c)


2892


ERROR: activateObjects: GET operation failed on T_DOMAIN

Description

The GUI tried to access the BEA TUXEDO MIB to retrieve attributes of the Domain. This call has failed. Look at surrounding entries in the ULOG to determine the cause of the failure. This is a non-critical, internal error and does not affect the GUI's functionality or performance. However, because of this error, the state of the Domain may be incorrectly displayed in the Tree.

Action

No action required.


2893


ERROR: activateObjects: will not send msg to tree to update view

Description

The GUI tried to access the BEA TUXEDO MIB to retrieve attributes of the Domain. This call has failed. Look at surrounding entries in the ULOG to determine the cause of the failure. This is a non-critical, internal error and does not affect the GUI's functionality or performance. However, because of this error, the state of the Domain may be incorrectly displayed in the Tree.

Action

No action is needed.


2894


ERROR: activate: failed to start tlisten process...

Description

The GUI was unable to start the tlisten process on the local site. Look at surrounding entries in the ULOG to determine the reason for the failure. This is a critical error and because of it, no MP mode tmboot(1) or tmshutdown(1) will succeed.

Action

Look in the ULOG to determine why the tlisten process could not be started. Start the tlisten process manually from the command line.

See Also

tlisten(1)


2895


ERROR: tpsetunsol failed: tperrno

Description

The GUI was unable to setup a handler to receive unsolicited notifications. Look at surrounding entries in the ULOG to determine the reason for the failure. This error will not affect the GUI's performance or functionality in any way. However, because of this error, the GUI will not display notification messages that are sent by TUXEDO System/T when server processes are booted/shutdown/restarted etc.

Action

No action is needed.

See Also

tpsetunsol(3c), tpchkunsol(3c)


2896


ERROR: activate: Get failed...cannot continue with object's activation

Description

The GUI was unable to access the BEA TUXEDO MIB. Look at surrounding entries in the ULOG to determine the reason for the failure. This is a critical error. The ongoing Activation action will not succeed.

Action

Contact your BEA TUXEDO system Technical Support and provide them with a description of action being performed along with relevant ULOGs.


2897


ERROR: tpalloc failed, tperrno=tperrno: error string

Description

The GUI made a call to tpalloc(3c) that failed. Look at surrounding entries in the ULOG to determine the cause of the failure. This is a critical error. The ongoing Activation, Deactivation or Migration action will not succeed.

Action

Contact your BEA TUXEDO system Technical Support and provide them with a description of action being performed along with relevant ULOGs.

See Also

tpalloc(3c)


2898


ERROR: Fldid32 failed, tperrno=tperrno: error string

Description

The GUI made a call to Fldid32(3fml) that failed. Look at surrounding entries in the ULOG to determine the cause of the failure. This is a critical error. The ongoing Activation, Deactivation or Migration action will not succeed.

Action

Contact your BEA TUXEDO system Technical Support and provide them with a description of action being performed along with relevant ULOGs.

See Also

Fldid32(3fml)


2899


ERROR: CFadd32 failed, tperrno=tperrno: error string

Description

The GUI made a call to CFadd32(3fml) that failed. Look at surrounding entries in the ULOG to determine the cause of the failure. This is a critical error. The ongoing Activation, Deactivation or Migration action will not succeed.

Action

Contact your BEA TUXEDO system Technical Support and provide them with a description of action being performed along with relevant ULOGs.

See Also

CFadd32(3fml)