BEA WebLogic Server 9.1 Diagnostics Schema Reference

http://www.bea.com/ns/weblogic/90/diagnostics
element alarm-type

Model
<alarm-type>annonymous type derived from string</alarm-type>
Disallowed substitutions (block)
none (extensions, restrictions and substitutions are allowed)
Substitution group exclusion (final)
none (extensions and restrictions are allowed)
Usage
Documentation

The alarm type for the watch: manual or automatic. The default alarm type is manual.

Once a manually set alarm has triggered, it must be reset through the WebLogic Server Administration Console or programmatically before it can trigger again. An automatic reset alarm will reset after the specified time period has elapsed.

Privileges: Read/Write

Default Value: None

MBean Attribute: WLDFWatchBean.AlarmType

Fundamental Facets
equality, non-numeric, unbounded, unordered, countable infinite value space
White Space Processing
preserve
Enumeration Facet
"None", "ManualReset", "AutomaticReset"
BEA WebLogic Server 9.1 Diagnostics Schema Reference

Version: 9.1