Skip Headers
Oracle® Configuration Manager Collection Overview
Release 10.3.4

Part Number E18036-01
Go to Documentation Home
Home
Go to Book List
Book List
Go to Table of Contents
Contents
Go to Feedback page
Contact Us

Go to previous page
Previous
View PDF

23 Siebel Collections

The Siebel collections include the following:

23.1 Siebel Component

The configuration categories and their associated configuration items for the Siebel Component target type follow.

23.1.1 Siebel Component Configuration

This metric captures details for the Siebel Component Configuration in parameter pairs of Property Name and Property Value. Not all Siebel components contain the same set of parameters so the actual output may vary from one component to another. For example, an Application Object Manager (AOM) component may have different parameters than a Transaction Router component. This generic pairing of Property Name and Property Value allows for any parameter to be captured for all Siebel components.

Following is an example of parameter pairs for the SCCObjMgr_enu component:

Property Name Property Value
datasource ServerDataSrc
host sdchpi01
maxtasks 500
maxmtservers 10
SIEBEL_ENTERPRISE sia80
SIEBEL_COMPNAME SCCObjMgr_enu

23.2 Siebel Component Group

The configuration categories and their associated configuration items for the Siebel Component Group target type follow.

23.2.1 Siebel Component Group Configuration

This metric captures details for the Siebel Component Group Configuration in parameter pairs of Property Name and Property Value. This is similar in nature to the Siebel Component Configuration, however the Component Groups will have the same Property Names for all groups (though the Property Values may be different). A Component Group Configuration is not the same as a Siebel component definition, although some of the same parameter names may appear.

Following is an example of parameter pairs for the Call Center component group:

Property Name Property Value
SIEBEL_COMPGROUP CallCenter
SIEBEL_ENTERPRISE sia80
SIEBEL_GATEWAY sdcp520a001

23.3 Siebel Enterprise

The configuration categories and their associated configuration items for the Siebel Enterprise target type follow.

23.3.1 Siebel Enterprise Configuration

This metric captures details for the Siebel Enterprise Configuration in parameter pairs of Property Name and Property Value. The Property Names are parameters that are appropriate for or affect the entire Siebel Enterprise. This would include Siebel Enterprise parameters as well as Siebel Named Subsystems. Named Subsystem Property Names are in the format of:

SubSys_<datasrc><parameter>
where 
  <datasrc> is the Siebel data source name, and 
  <parameter> is the parameter name in that Siebel data source

Following is an example of parameter pairs for a Siebel Enterprise:

Property Name Property Value
filesystem vol1/sia80ora/siebsrvr/fs
secadptmode DB
secadptname DBSecAdpt
SIEBEL_GATEWAY sdchpi01
SubSys_DBSecAdptdatasourcename ServerDataSrc
SubSys_GatewayDataSrcdsconnectstring sdchpi01:3220
SubSys_ServerDataSrcdsmaxcursorsize -1
tableowner usia05

23.4 Siebel Gateway

The configuration categories and their associated configuration items for the Siebel Gateway target type follow.

23.4.1 Siebel Gateway Configuration

This metric captures details for the Siebel Gateway Configuration in parameter pairs of Property Name and Property Value. The Property Names are parameters that are appropriate for or affect the Siebel Gateway.

Following is an example of parameter pairs for a Siebel Gateway:

Property Name Property Value
host sdchpi01
SIEBEL_GATEWAY sdchpi01

23.5 Siebel Server

The configuration categories and their associated configuration items for the Siebel Server target type follow.

23.5.1 Siebel Server System Configuration

This metric captures details for the Siebel Server System Configuration in parameter pairs of Property Name and Property Value. The Property Names gathered for this section contains the Siebel server parameter names while the Property Values are those specific to the settings for this Siebel server.

Following is an example of parameter pairs for a Siebel Server System Configuration:

Property Name Property Value
host sdchpi01
logdir /vol1/sia80ora/siebsrvr/enterprises/sia80/srvr1/log
rootdir /vol1/sia80ora/siebsrvr
SIEBEL_ENTERPRISE sia80
SIEBEL_SERVER srvr1

23.5.2 Siebel Server General Configuration

This metric captures details for the Siebel Server General Configuration in parameter pairs of Property Name and Property Value. The Property Names gathered for this section are not necessarily Siebel server parameter settings, but could contain applicable details for the Siebel server which might be found in other files on the server (such as base.txt). These Property Names would be associated with their corresponding Property Values.

Following is an example of parameter pairs for a Siebel Server General Configuration:

Property Name Property Value
Base File Contents 8.0.0.2 SIA [20412] LANG_INDEPENDENT
Enabled Languages enu;fra;