NAME | SYNOPSIS | DESCRIPTION | OPTIONS | DIAGNOSTICS | RESTRICTIONS FOR ChorusOS | ATTRIBUTES
dd is a target utility.
The dd utility copies the standard input to the standard output. Input data is read and written in 512-byte blocks. If input reads are short, input from multiple reads are aggregated to form the output block. When finished, dd displays the number of complete and partial input and output blocks and truncated input records to the standard error output.
The options are:
Set both input and output block size, superseding the ibs and obs operands. If no conversion values other than noerror, notrunc or sync are specified, each input block is copied to the output as a single block without any aggregation of short blocks.
Set the conversion record size to n bytes. The conversion record size is required by the record oriented conversion values.
Copy only n input blocks.
Copy n input files before terminating. This operand is only applicable when the input device is a tape.
Set the input block size to n bytes instead of the default of 512.
Read input from file instead of the standard input.
Set the output block size to n bytes instead of the default of 512.
Write output to file instead of the standard output. Any regular output file is truncated unless the notrunc conversion value is specified. If an initial portion of the output file is skipped (see the seek operand) the output file is truncated at that point.
Seek n blocks from the beginning of the output before copying. On non-tape devices, a lseek 2 operation is used. Otherwise, existing blocks are read and the data discarded. If the user does not have read permission for the tape, it is positioned using the tape ioctl 2 function calls. If the seek operation is past the end of file, space from the current end of file to the specified offset is filled with blocks of NUL bytes.
Skip n blocks from the beginning of the input before copying. On input which supports seeks, a lseek 2 operation is used. Otherwise, input data is read and discarded. For pipes, the correct number of bytes is read. For all other devices, the correct number of blocks is read without distinguishing between a partial or complete block.
Where value is one of the symbols from the following list:
The same as the unblock value except that characters are translated from ECBDIC to ASCII before the records are converted. (These values imply unblock if the operand cbs is also specified.) There are two conversion maps for ASCII. The value ascii specifies the recommended one which is compatible with System V. The value oldascii specifies the one used in historic AT&T and pre-4.3BSD-reno systems.
Treats the input as a sequence of newline or end-of-file terminated variable length records independent of input and output block boundaries. Any trailing newline character is discarded. Each input record is converted to a fixed length output record where the length is specified by the cbs operand. Input records shorter than the conversion record size are padded with spaces. Input records longer than the conversion record size are truncated. The number of truncated input records, if any, are reported to the standard error output at the completion of the copy.
The same as the block value except that characters are translated from ASCII to EBCDIC after the records are converted. (These values imply block if the operand cbs is also specified.) There are four conversion maps for EBCDIC. The value ebcdic specifies the recommended one, which is compatible with System V. The value ibm is a slightly different mapping, which is compatible with the AT&T System V ibm value. The values oldebcdic and oldibm are maps used in historic AT&Tand pre-4.3BSD-reno systems.
Transform uppercase characters into lowercase characters.
Do not stop processing on an input error. When an input error occurs, a diagnostic message followed by the current input and output block counts will be written to the standard error output in the same format as the standard completion message. If the sync conversion is also specified, any missing input data will be replaced with NUL bytes (or with spaces if a block oriented conversion value was specified) and processed as a normal input buffer. If the sync conversion is not specified, the input block is omitted from the output. On input of files which are not tapes or pipes, the file offset will be positioned past the block in which the error occurred using lseek 2.
Do not truncate the output file. This will preserve any blocks in the output file not explicitly written by dd. The notrunc value is not supported for tapes.
Pad the final output block to the full output block size. If the input file is not a multiple of the output block size after conversion, this conversion forces the final output block to be the same size as preceding blocks for use on devices that require regularly sized blocks to be written. This option is incompatible with use of the bs=n block size specification.
Swap every pair of input bytes. If an input buffer has an odd number of bytes, the last byte will be ignored during swapping.
Pad every input block to the input buffer size. Spaces are used to pad bytes if a block oriented conversion value is specified, otherwise NUL bytes are used.
Transform lowercase characters into uppercase characters.
Treats the input as a sequence of fixed length records independent of input and output block boundaries. The length of the input records is specified by the cbs operand. Any trailing space characters are discarded and a newline character is appended.
Where sizes are specified, a decimal number of bytes is expected. If the number ends with a ``b'', ``k'', ``m'' or ``w'', the number is multiplied by 512, 1024 (1K), 1048576 (1M) or the number of bytes in an integer, respectively. Two or more numbers may be separated by an ``x'' to indicate a product.
When finished, dd displays the number of complete and partial input and output blocks, truncated input records and odd-length byte-swapping blocks to the standard error output. A partial input block is one where less than the input block size was read. A partial output block is one where less than the output block size was written. Partial output blocks to tape devices are considered fatal errors. Otherwise, the rest of the block will be written. Partial output blocks to character devices will produce a warning message. A truncated input block is one where a variable length record oriented conversion value was specified, and the input line was too long to fit in the conversion record, or was not newline terminated.
Normally, data resulting from input or conversion or both are aggregated into output blocks of the specified size. After the end of input is reached, any remaining output is written as a block. This means that the final output block may be shorter than the output block size.
If successful, the dd utility returns 0, otherwise >0 if an error occurred.
The files operand and the ascii, ebcdic, ibm, oldascii, oldebcdic, and oldibm values are extensions to the POSIX standard.
Tapes are not currently supported with this utility.
See attributes(5) for descriptions of the following attributes:
ATTRIBUTE TYPE | ATTRIBUTE VALUE |
---|---|
Interface Stability | Evolving |
NAME | SYNOPSIS | DESCRIPTION | OPTIONS | DIAGNOSTICS | RESTRICTIONS FOR ChorusOS | ATTRIBUTES