Sun Cluster 3.0 Hardware Guide

Example--Adding a StorEdge MultiPack Disk Drive

The following example shows how to apply the procedure for adding a StorEdge MultiPack enclosure disk drive.


# scdidadm -l
16       phys-circinus-3:/dev/rdsk/c2t0d0 /dev/did/rdsk/d16    
17       phys-circinus-3:/dev/rdsk/c2t1d0 /dev/did/rdsk/d17    
18       phys-circinus-3:/dev/rdsk/c2t2d0 /dev/did/rdsk/d18    
19       phys-circinus-3:/dev/rdsk/c2t3d0 /dev/did/rdsk/d19    
...
26       phys-circinus-3:/dev/rdsk/c2t12d0 /dev/did/rdsk/d26    
30       phys-circinus-3:/dev/rdsk/c1t2d0 /dev/did/rdsk/d30    
31       phys-circinus-3:/dev/rdsk/c1t3d0 /dev/did/rdsk/d31    
32       phys-circinus-3:/dev/rdsk/c1t10d0 /dev/did/rdsk/d32    
33       phys-circinus-3:/dev/rdsk/c0t0d0 /dev/did/rdsk/d33    
34       phys-circinus-3:/dev/rdsk/c0t6d0 /dev/did/rdsk/d34    
8190     phys-circinus-3:/dev/rmt/0     /dev/did/rmt/2   
# cfgadm -c configure c1
# devfsadm
# scgdevs
Configuring DID devices
Could not open /dev/rdsk/c0t6d0s2 to verify device id.
        Device busy
Configuring the /dev/global directory (global devices)
obtaining access to all attached disks
reservation program successfully exiting
# scdidadm -l
16       phys-circinus-3:/dev/rdsk/c2t0d0 /dev/did/rdsk/d16    
17       phys-circinus-3:/dev/rdsk/c2t1d0 /dev/did/rdsk/d17    
18       phys-circinus-3:/dev/rdsk/c2t2d0 /dev/did/rdsk/d18    
19       phys-circinus-3:/dev/rdsk/c2t3d0 /dev/did/rdsk/d19    
...
26       phys-circinus-3:/dev/rdsk/c2t12d0 /dev/did/rdsk/d26    
30       phys-circinus-3:/dev/rdsk/c1t2d0 /dev/did/rdsk/d30    
31       phys-circinus-3:/dev/rdsk/c1t3d0 /dev/did/rdsk/d31    
32       phys-circinus-3:/dev/rdsk/c1t10d0 /dev/did/rdsk/d32    
33       phys-circinus-3:/dev/rdsk/c0t0d0 /dev/did/rdsk/d33    
34       phys-circinus-3:/dev/rdsk/c0t6d0 /dev/did/rdsk/d34    
35       phys-circinus-3:/dev/rdsk/c2t13d0 /dev/did/rdsk/d35    
8190     phys-circinus-3:/dev/rmt/0     /dev/did/rmt/2       
#