The following example shows how to apply the procedure for adding a StorEdge D1000 disk array disk drive.
# scdidadm -l
16 phys-circinus-3:/dev/rdsk/c2t0d0 /dev/did/rdsk/d16
17 phys-circinus-3:/dev/rdsk/c2t1d0 /dev/did/rdsk/d17
18 phys-circinus-3:/dev/rdsk/c2t2d0 /dev/did/rdsk/d18
19 phys-circinus-3:/dev/rdsk/c2t3d0 /dev/did/rdsk/d19
...
26 phys-circinus-3:/dev/rdsk/c2t12d0 /dev/did/rdsk/d26
30 phys-circinus-3:/dev/rdsk/c1t2d0 /dev/did/rdsk/d30
31 phys-circinus-3:/dev/rdsk/c1t3d0 /dev/did/rdsk/d31
32 phys-circinus-3:/dev/rdsk/c1t10d0 /dev/did/rdsk/d32
33 phys-circinus-3:/dev/rdsk/c0t0d0 /dev/did/rdsk/d33
34 phys-circinus-3:/dev/rdsk/c0t6d0 /dev/did/rdsk/d34
8190 phys-circinus-3:/dev/rmt/0 /dev/did/rmt/2
# cfgadm -c configure c1
# devfsadm
# scgdevs
Configuring DID devices
Could not open /dev/rdsk/c0t6d0s2 to verify device id.
Device busy
Configuring the /dev/global directory (global devices)
obtaining access to all attached disks
reservation program successfully exiting
# scdidadm -l
16 phys-circinus-3:/dev/rdsk/c2t0d0 /dev/did/rdsk/d16
17 phys-circinus-3:/dev/rdsk/c2t1d0 /dev/did/rdsk/d17
18 phys-circinus-3:/dev/rdsk/c2t2d0 /dev/did/rdsk/d18
19 phys-circinus-3:/dev/rdsk/c2t3d0 /dev/did/rdsk/d19
...
26 phys-circinus-3:/dev/rdsk/c2t12d0 /dev/did/rdsk/d26
30 phys-circinus-3:/dev/rdsk/c1t2d0 /dev/did/rdsk/d30
31 phys-circinus-3:/dev/rdsk/c1t3d0 /dev/did/rdsk/d31
32 phys-circinus-3:/dev/rdsk/c1t10d0 /dev/did/rdsk/d32
33 phys-circinus-3:/dev/rdsk/c0t0d0 /dev/did/rdsk/d33
34 phys-circinus-3:/dev/rdsk/c0t6d0 /dev/did/rdsk/d34
35 phys-circinus-3:/dev/rdsk/c2t13d0 /dev/did/rdsk/d35
8190 phys-circinus-3:/dev/rmt/0 /dev/did/rmt/2
|