The following example shows how to apply the procedure for replacing a StorEdge A5x00 disk array disk drive.
# scstat -q # scdidadm -l d4 4 phys-schost-2:/dev/rdsk/c1t32d0 /dev/did/rdsk/d4 # scdidadm -o diskid -l c1t32d0 2000002037000edf # prtvtoc /dev/rdsk/c1t32d0s2 > /usr/tmp/c1t32d0.vtoc # luxadm remove -F /dev/rdsk/c1t32d0s2 WARNING!!! Please ensure that no filesystems are mounted on these device(s). All data on these devices should have been backed up. The list of devices that will be removed is: 1: Box Name "venus1" front slot 0 Please enter 'q' to Quit or <Return> to Continue: <Return> stopping: Drive in "venus1" front slot 0....Done offlining: Drive in "venus1" front slot 0....Done Hit <Return> after removing the device(s). <Return> Drive in Box Name "venus1" front slot 0 Logical Nodes being removed under /dev/dsk/ and /dev/rdsk: c1t32d0s0 c1t32d0s1 c1t32d0s2 c1t32d0s3 c1t32d0s4 c1t32d0s5 c1t32d0s6 c1t32d0s7 # devfsadm # fmthard -s /usr/tmp/c1t32d0.vtoc /dev/rdsk/c1t32d0s2 # scswitch -S -h node1 # shutdown -y -g0 -i6 # scdidadm -R d4 # scdidadm -o diskid -l c1t32d0 20000020370bf955 # scdidadm -ui |