Sun Cluster 3.0 U1 Release Notes Supplement

How to Replace a Controller Card, FC Switch, or Disk Tray-to-Switch Component in a Running Cluster

Use this procedure to replace a failed disk tray controller card, an FC switch, or the following disk tray-to-switch components in a running cluster:

  1. Telnet to the disk tray that is connected to the controller card, FC switch, or component that you are replacing.

  2. Use the T3/T3+ sys stat command to view the controller status for the two disk trays of the partner group.

    In the following example, both controllers are ONLINE.


    t3:/:<#> sys stat
    Unit   State      Role    Partner
    -----  ---------  ------  -------
     1    ONLINE     Master    2
     2    ONLINE     AlterM    1

    See the Sun StorEdge T3 and T3+ Array Administrator's Guide for more information about the sys stat command.

  3. Is the controller card, FC switch, or component that you are replacing attached to a disk tray controller that is ONLINE or DISABLED, as determined in Step 2?

    • If the controller is already DISABLED, go to Step 5.

    • If the controller is ONLINE, use the T3/T3+ disable command to disable it. Using the example from Step 2, if you want to disable Unit 1, enter the following:


      t3:/:<#> disable u1
      

    See the Sun StorEdge T3 and T3+ Array Administrator's Guide for more information about the disable command.

  4. Use the T3/T3+ sys stat command to verify that the controller's state has been changed to DISABLED.


    t3:/:<#> sys stat
    Unit   State      Role    Partner
    -----  ---------  ------  -------
     1    DISABLED   Slave     
     2    ONLINE     Master    

  5. Replace the component using the following references:

    • For the procedure on replacing a disk tray controller card, see the Sun StorEdge T3 and T3+ Array Installation, Operation, and Service Manual.

    • For the procedure on replacing a fiber optic cable between a disk tray and an FC switch, see the Sun StorEdge network FC switch-8 and switch-16 Installation and Configuration Guide.

    • For the procedure on replacing a GBIC on an FC switch, see the Sun StorEdge network FC switch-8 and switch-16 Installation and Configuration Guide.

    • For the procedure on replacing a StorEdge network FC switch-8 or switch-16, or an FC switch power cord, see the Sun StorEdge network FC switch-8 and switch-16 Installation and Configuration Guide.

    • For the procedure on replacing an MIA, see the Sun StorEdge T3 and T3+ Array Installation, Operation, and Service Manual.

    • For the procedure on replacing interconnect cables, see the Sun StorEdge T3 and T3+ Array Installation, Operation, and Service Manual.

  6. If necessary, telnet to the disk tray of the partner group that is still online.

  7. Use the T3/T3+ enable command to reenable the disk tray that you disabled in Step 3.


    t3:/:<#> enable u1
    

    See the Sun StorEdge T3 and T3+ Array Administrator's Guide for more information about the enable command.

  8. Use the T3/T3+ sys stat command to verify that the controller's state has been changed to ONLINE.


    t3:/:<#> sys stat
    Unit   State      Role    Partner
    -----  ---------  ------  -------
     1    ONLINE     AlterM    2
     2    ONLINE     Master    1