Sun Cluster 3.0 12/01 Release Notes Supplement

Bug ID 4626010

Problem Summary: In a Sun StorEdge 3900 Series system, the preconfigured, default hard zones that are used on the Sun StorEdge Network FC Switch-8 and Switch-16 switches are incompatible for use with host-based mirroring in a cluster. The hard zones prevent the cluster nodes from seeing all attached storage because there are only two ports per zone.

Workaround: Remove the default hard zones from the Sun StorEdge Network FC Switch-8 and Switch-16 switches (this is documented as a necessary step in the procedures in Appendix C, Installing and Maintaining a Sun StorEdge 3900 or 6900 Series System. See the SANbox-8/16 Switch Management User's Manual for instructions on removing the preconfigured hard zones on all Sun StorEdge Network FC Switch-8 and Switch-16 switches.