啟動叢集節點會受到法定數目配置的影響。 在兩個節點叢集中,必須配置一個法定裝置,以便使叢集的法定總計數為三。 每一個節點都應有一個法定計數,以及一個法定計數用於法定裝置。 在這個情況下,如果第一個節點關閉,第二個節點會使法定裝置繼續當作單獨的叢集成員執行。 如果第一個節點作為叢集節點返回叢集中,必須開啟並執行第二個節點。 必要的叢集法定計數 (二) 必須存在。
SPARC︰
ok boot |
x86︰
<<< Current Boot Parameters >>> Boot path: /pci@0,0/pci8086,2545@3/pci8086,1460@1d/pci8086,341a@7,1/ sd@0,0:a Boot args: Type b [file-name] [boot-flags] <ENTER> to boot with options or i <ENTER> to enter boot interpreter or <ENTER> to boot with defaults <<< timeout in 5 seconds >>> Select (b)oot or (i)nterpreter: b |
叢集節點和叢集交互連接之間必須有運轉中的連線,才能夠成為叢集成員。
確認節點啟動成功而且是在線上狀態。
scstat 指令報告節點的狀態。
# scstat -n |
如果叢集節點的 /var 檔案系統已滿,Sun Cluster 可能無法在該節點上重新啟動。 如果發生此問題,請參閱如何修復整個 /var 檔案系統。
以下範例顯示 phys-schost-1 節點啟動為叢集時的主控台輸出。
ok boot Rebooting with command: boot ... Hostname: phys-schost-1 Booting as part of a cluster ... NOTICE: Node phys-schost-1: attempting to join cluster ... NOTICE: Node phys-schost-1: joined cluster ... The system is coming up. Please wait. checking ufs filesystems ... reservation program successfully exiting Print services started. volume management starting. The system is ready. phys-schost-1 console login: |
以下範例顯示 phys-schost-1 節點啟動為叢集時的主控台輸出。
<<< Current Boot Parameters >>> Boot path: /pci@0,0/pci8086,2545@3/pci8086,1460@1d/pci8086,341a@7,1/sd@0,0:a Boot args: Type b [file-name] [boot-flags] <ENTER> to boot with options or i <ENTER> to enter boot interpreter or <ENTER> to boot with defaults <<< timeout in 5 seconds >>> Select (b)oot or (i)nterpreter: Size: 276915 + 22156 + 150372 Bytes /platform/i86pc/kernel/unix loaded - 0xac000 bytes used SunOS Release 5.9 Version on81-feature-patch:08/30/2003 32-bit Copyright 1983-2003 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. configuring IPv4 interfaces: e1000g2. Hostname: phys-schost-1 Booting as part of a cluster NOTICE: CMM: Node phys-schost-1 (nodeid = 1) with votecount = 1 added. NOTICE: CMM: Node phys-schost-2 (nodeid = 2) with votecount = 1 added. NOTICE: CMM: Quorum device 1 (/dev/did/rdsk/d1s2) added; votecount = 1, bitmask of nodes with configured paths = 0x3. WARNING: CMM: Initialization for quorum device /dev/did/rdsk/d1s2 failed with error EACCES. Will retry later. NOTICE: clcomm: Adapter e1000g3 constructed NOTICE: clcomm: Path phys-schost-1:e1000g3 - phys-schost-2:e1000g3 being constructed NOTICE: clcomm: Path phys-schost-1:e1000g3 - phys-schost-2:e1000g3 being initiated NOTICE: clcomm: Path phys-schost-1:e1000g3 - phys-schost-2:e1000g3 online NOTICE: clcomm: Adapter e1000g0 constructed NOTICE: clcomm: Path phys-schost-1:e1000g0 - phys-schost-2:e1000g0 being constructed NOTICE: CMM: Node phys-schost-1: attempting to join cluster. WARNING: CMM: Reading reservation keys from quorum device /dev/did/rdsk/d1s2 failed with error 2. NOTICE: CMM: Cluster has reached quorum. NOTICE: CMM: Node phys-schost-1 (nodeid = 1) is up; new incarnation number = 1068503958. NOTICE: CMM: Node phys-schost-2 (nodeid = 2) is up; new incarnation number = 1068496374. NOTICE: CMM: Cluster members: phys-schost-1 phys-schost-2. NOTICE: CMM: node reconfiguration #3 completed. NOTICE: CMM: Node phys-schost-1: joined cluster. NOTICE: clcomm: Path phys-schost-1:e1000g0 - phys-schost-2:e1000g0 being initiated NOTICE: clcomm: Path phys-schost-1:e1000g0 - phys-schost-2:e1000g0 online NOTICE: CMM: Retry of initialization for quorum device /dev/did/rdsk/d1s2 was successful. WARNING: mod_installdrv: no major number for rsmrdt ip: joining multicasts failed (18) on clprivnet0 - will use link layer broadcasts for multicast The system is coming up. Please wait. checking ufs filesystems /dev/rdsk/c1t0d0s5: is clean. NIS domain name is dev.eng.mycompany.com starting rpc services: rpcbind keyserv ypbind done. Setting netmask of e1000g2 to 255.255.255.0 Setting netmask of e1000g3 to 255.255.255.128 Setting netmask of e1000g0 to 255.255.255.128 Setting netmask of clprivnet0 to 255.255.255.0 Setting default IPv4 interface for multicast: add net 224.0/4: gateway phys-schost-1 syslog service starting. obtaining access to all attached disks ***************************************************************************** * * The X-server can not be started on display :0... * ***************************************************************************** volume management starting. Starting Fault Injection Server... The system is ready. phys-schost-1 console login: |