以下示例将群集节点置于维护状态并检验了操作结果。scstat -q 的输出信息显示 phys-schost-1 的 Node votes 为 0(零),并且其状态为 Offline。Quorum Summary 还将显示减少后的选票计数。视具体的配置情况而定,Quorum Votes by Device 的输出信息可能也会表明某些定额磁盘设备已脱机。
[在要进入维护状态的节点上:] phys-schost-1# scswitch -S -h phys-schost-1 phys-schost-1# shutdown -g0 -y -i0 [在群集中另一个节点上:] phys-schost-2# scconf -c -q node=phys-schost-1,maintstate phys-schost-2# scstat -q -- Quorum Summary -- Quorum votes possible: 3 Quorum votes needed: 2 Quorum votes present: 3 -- Quorum Votes by Node -- Node Name Present Possible Status --------- ------- -------- ------ Node votes: phys-schost-1 0 0 Offline Node votes: phys-schost-2 1 1 Online Node votes: phys-schost-3 1 1 Online -- Quorum Votes by Device -- Device Name Present Possible Status ----------- ------- -------- ------ Device votes: /dev/did/rdsk/d3s2 0 0 Offline Device votes: /dev/did/rdsk/d17s2 0 0 Offline Device votes: /dev/did/rdsk/d31s2 1 1 Online |