Sun Cluster Data Service for SAP Web Application Server Guide for Solaris OS

SUNW.sapenq Extension Properties

The SUNW.sapenq resource type represents the SAP enqueue server in a Sun Cluster configuration. The extension properties of this resource type are as follows:

Child_mon_level

The child process monitoring level for the Process Monitor Facility (PMF). This property is equivalent to the -C option of pmfadm.

The default value of -1 indicates that child process monitoring is not to be performed. Positive values indicate the desired level of child process monitoring.

Data type

Integer

Default

-1

Range

No range defined

Tunable

Any time

Enqueue_Instance_Number

The two-digit instance number for the SAP enqueue server. This number is the value of SAPSYSTEM in the SAP profile for SAP enqueue server.

Data type

String

Default

No default defined

Range

Not applicable

Tunable

When disabled

Enqueue_Profile

The full path to the SAP enqueue server profile.

Data type

String

Default

No default defined

Range

Not applicable

Tunable

When disabled

Enqueue_Server

The full path to the SAP enqueue server executable.

Data type

String

Default

No default defined

Range

Not applicable

Tunable

When disabled

Enqueue_Server_Monitor

The full path to the SAP enqueue server monitor executable.

Data type

String

Default

directory/ensmon, where directory is the full path to the directory where the SAP enqueue server executable is stored, as specified by the extension property Enqueue_Server.

Range

Not applicable

Tunable

When disabled

Log_Directory

The directory for the startup and monitor log files.

Data type

String

Default

The home directory of the administration user, as specified by the extension property SAP_User.

Range

Not applicable

Tunable

When disabled

Monitor_retry_count

The maximum number of restarts by the Process Monitor Facility (PMF) that are allowed for the SAP enqueue server fault monitor.

Data type

Integer

Default

4

Range

No range defined

Tunable

Any time

Monitor_retry_interval

The interval in minutes between restarts of the SAP enqueue server fault monitor.

Data type

Integer

Default

2

Range

No range defined

Tunable

Any time

Probe_timeout

The timeout value in seconds that the SAP enqueue server fault monitor uses to probe an SAP enqueue server instance.

Data type

Integer

Default

120

Range

Minimum = 2; no maximum defined

Tunable

Any time

SAP_User

The administration user for the SAP enqueue server.

Data type

String, where letters are in lowercase

Default

No default defined

Range

Not applicable

Tunable

When disabled

Stop_signal

The signal that is sent to the application to stop the SAP enqueue server application.

Data type

Integer

Default

2 (equivalent to SIGINT)

Range

1–37

Tunable

When disabled