This following information was omitted from the “Installation Overview” section in the Sun Management Center 3.5 Installation and Configuration Guide.
The Sun Management Center 3.5 documentation is available at http://docs.sun.com and on disk 2 of the product media. To read the documentation from the media, follow these steps:
Open a web browser window.
From the web browser window, open the /cdrom/cdrom0/image/index.html file, which is located on disk 2.
Follow the appropriate links to access HTML or PDF documentation in your preferred language.
To install the documentation from the media, you have two options:
Install the documentation during the product installation.
Use the pkgadd command to install the packages that are located in the following directory on disk 2:
/cdrom/cdrom0/image/PE/CommonForSolaris/Basic |
The title and description for the section“Sun StorEdgeTM A500 Patches” in the Sun Management Center 3.5 Installation and Configuration Guide are wrong. The correct title is Sun StorEdge A5x00 Packages (not Patches).
The following is the correct description for the section Sun StorEdge A5x00 Packages:
If you want to use the Sun StorEdge A5x00 module, you must install the SUNWluxop and SUNWluxox packages on the system where you install the Monitoring and Management of A5x00 and T3 Devices add-on product. If you load the A5x00 module, and the packages are not installed on the system, the Sun Management Center agent cannot run.
To check whether the packages are installed, type the following command:
# pkginfo SUNWluxop SUNWluxox |
If the packages are installed, the following lines are displayed:
system SUNWluxop Sun Enterprise Network Array firmware and utilities system SUNWluxox Sun Enterprise Network Array libraries (64-bit) |
If you need either package, you can download the package from http://sunsolve.sun.com. Make sure that you download the latest revision. Use the pkgadd(1M) command to install the packages.
Sun Management Center 3.5 Update 1 requires the latest patch for the SUNWluxop package. See A5x00 Module Does Not Populate Tables With Values (4973319).
The title and information in the section, Removing T3 Device Configuration If Present, located in the “T3 Storage Devices” in Sun Management Center 3.5 Installation and Configuration Guide section has changed. The corrected version is as follows:
Uninstalling T3 Storage Devices
If you are running Sun Management Center 3.5, you must remove the T3 device configuration from Sun Management Center 3.5 if you are going to perform any of the following functions:
Remove the T3 storage device
Move the T3 storage device to another machine
Assign a different IP or Ethernet address to the T3 storage device
Migrate the Sun Management Center server to a different machine
Uninstall the Monitoring and Management of A5x00 and T3 Devices add-on product
Uninstall Sun Management Center 3.5
If you uninstall the Monitoring and Management of A5x00 and T3 Devices add-on product without first removing the T3 device configuration, you can remove the T3 device configuration as described in the following procedure.
The corrected procedure is as follows:
Log in as root on the machine where the Monitoring and Management of A5x00 and T3 Devices add-on product is installed.
Type the following command to stop the Sun Management Center agent.
#/opt/SUNWsymon/es-stop -a |
Run the pre-uninstall script to remove T3 device configuration information.
Type the command /opt/SUNWsymon/addons/storage/sbin/pre-uninst.sh.
When asked whether you want to stop the T3 from sending syslog messages, type y.
You are then prompted for the root password for the T3 device.
Type the password.
You are notified that the T3 device has been removed from the T3 module.
Uninstall the add-on product.
Step 4 of the “To Install Sun Management Center 3.5 on the Solaris Platform” procedure in the Sun Management Center 3.5 Installation and Configuration Guide incorrectly lists the file /disk1/sbin/INSTALL.README. The correct file name is /disk1/sbin/README.INSTALL.
The first paragraph of the section, “Creating Agent Installation and Update Images” in Sun Management Center 3.5 Installation and Configuration Guide omitted the following information. Agent-update images are supported on systems that have only the Sun Management Center agent component installed. If you try to use agent-update images on systems where you have installed the agent as well as the server or console or all three layers at the same time, the operation fails.
Step 6 of the procedure, “To Install Sun Management Center 3.5 on Microsoft Windows” in Sun Management Center 3.5 Installation and Configuration Guide says the default location in which to install Sun Management Center is C:\ProgramFiles\SunMC. This path is wrong. The default location is C:\ProgramFiles\SUNWsymon.
The current description of the esadm security group in the “Setting Up Users” in Sun Management Center 3.5 Installation and Configuration Guide section mentions that esadm permits members to create top-level domains in a server context and assign privileges for other Sun Management Center users within these domains. The esadm security group does not provide the stated privileges: esadm users cannot create top-level domains and assign privileges within said domains.
“es-config Options” table in the “Reconfiguring Sun Management Center Ports” section omitted the following parameter.
Option |
Description |
---|---|
-r |
Re-seed Sun Management Center components. If the SUNWcry package is installed, you are prompted to enable SNMP encryption (privacy). For more information, see the Sun Management Center 3.5 Update 1 Supplement. |
The following information for the -P option is incorrect: The range of ports for the -P option must be at least 100, for example, 1024:1124 where 1024 is the MinPort and 1124 is the MaxPort. The correct information is as follows: The range of ports must be 20 ports or larger, for example, 1024:1044. The minimum specified ports for -P is 20.
Step 3 in the procedure, “To Restrict the Firewall Port Range” in Sun Management Center 3.5 Installation and Configuration Guide incorrectly says: “You are asked whether you want to start the Sun Management Center components.” The software does not prompt you to start the Sun Management Center components. These components are started automatically.
The following localization packages were omitted from the “Sun Management Center 3.5 Packages” section in the Sun Management Center 3.5 Installation and Configuration Guide.
Table 4–1 Sun Management Center 3.5 Localization Packages
Package Name |
Package Description |
---|---|
SunWfresf |
Sun Management Center message files for French |
SUNWjaesf |
Sun Management Center message files for Japanese |
SUNWkoesf |
Sun Management Center message files for Korean |
SUNWcesf |
Sun Management Center message files for Simplified Chinese |
SUNWhesf |
Sun Management Center message files for Traditional Chinese |
SUNWfresi |
Sun Management Center installation message files for French |
SUNWjaesi |
Sun Management Center installation message files for Japanese |
SUNWkoesi |
Sun Management Center installation message files for Korean |
SUNWcesi |
Sun Management Center installation message files for Simplified Chinese |
SUNWhesi |
Sun Management Center installation message files for Traditional Chinese |
SUNWfresh |
Sun Management Center Help for French |
SUNWjaesh |
Sun Management Center Help for Japanese |
SUNWkoesh |
Sun Management Center Help for Korean |
SUNWcesh |
Sun Management Center Help for Simplified Chinese |
SUNWhesh |
Sun Management Center Help for Traditional Chinese |
Table 4–2 Sun Management Center 3.5 Advanced System Monitoring Localization Packages
Package Name |
Package Description |
---|---|
SUNWfram |
Sun Management Center Advance Monitoring Add-On Product – French |
SUNWjaam |
Sun Management Center Advance Monitoring Add-On Product - Japanese |
SUNWkoam |
Sun Management Center Advance Monitoring Add-On Product - Korean |
SUNWcam |
Sun Management Center Advance Monitoring Add-On Product - Simplified Chinese |
SUNWham |
Sun Management Center Advance Monitoring Add-On Product - Traditional Chinese |
Table 4–3 Sun Management Center 3.5 TNG integration Localization Packages
Package Name |
Package Description |
---|---|
SUNWfrcam |
Sun Management Center - TNG integration French message files |
SUNWjacam |
Sun Management Center - TNG integration Japanese message files |
SUNWkocam |
Sun Management Center - TNG integration Korean message files |
SUNWccam |
Sun Management Center - TNG integration Simplified Chinese message files |
SUNWhcam |
Sun Management Center - TNG integration Traditional Chinese message files |
Table 4–4 Sun Management Center 3.5 Tivoli TEC Localization Packages
Package Name |
Package Description |
---|---|
SUNWfrtia |
Sun Management Center Tivoli TEC - French |
SUNWjatia |
Sun Management Center Tivoli TEC - Japanese |
SUNWkotia |
Sun Management Center Tivoli TEC - Korean |
SUNWctia |
Sun Management Center Tivoli TEC - Simplified Chinese |
SUNWhtia |
Sun Management Center Tivoli TEC - Traditional Chinese |
Table 4–5 Sun Management Center 3.5 Storage (A5x00/T3) Module Localization Packages
Package Name |
Package Description |
---|---|
SUNWfrstm |
Sun Management Center Storage Module - French |
SUNWjastm |
Sun Management Center Storage Module - Japanese |
SUNWkostm |
Sun Management Center Storage Module - Korean |
SUNWcstm |
Sun Management Center Storage Module - Simplified Chinese |
SUNWhstm |