You can examine alarm values and set alarm actions with the following commands:
Description
The ackAlarms command acknowledges alarms in an agent or a list of agents.
Syntax
ackAlarms a=host[:port][,host[:port]]* [domain=domain] [m=module[+instance][mgtObj=managedObject [property=property [propInst=propertyInstance] [qualifier=qualifier]]]] [severity=DIS|DWN|ERR|INF|IRR|OFF|WRN] [state=OPEN|CLOSED|FIXED] [note=reason]
Parameters
a, domain, m, mgtObj, property, propInst, qualifier, severity, state, and note.
If no value is specified for the state parameter, state defaults to Open.
Description
The delAlarms command deletes alarms in an agent or a list of agents.
Syntax
delAlarms a=host[:port][,host[:port]]* [domain=domain] [m=module[+instance][mgtObj=managedObject [property=property [propInst=propertyInstance] [qualifier=qualifier]]]] [severity=DIS|DWN|ERR|INF|IRR|OFF|WRN] [state=OPEN|CLOSED|FIXED] [ack=ACK|NOACK] [note=reason]
Parameters
a, domain, m, mgtObj, property, propInst, qualifier, severity, state, ack, and note.
If no value is specified for the state parameter, state defaults to Closed.
Description
The getAlarms command retrieves alarm information for an agent or a set of agents.
Syntax
getAlarms a=host[:port][,host[:port]]* [domain=domain] [m=module[+instance][mgtObj=managedObject [property=property [propInst=propertyInstance] [qualifier=qualifier]]]] [severity=DIS|DWN|ERR|INF|IRR|OFF|WRN] [state=OPEN|CLOSED|FIXED] [ack=ACK|NOACK]
Parameters
a, domain, m, mgtObj, property, propInst, qualifier, severity, state, and ack.
If no parameters are specified, getAlarms returns all alarm information.
Description
The runAlarmAction command runs a manual or delayed alarm action for all alarms under a domain of an agent or a list of agents.
Syntax
runAlarmAction a=host[:port][,host[:port]]* [domain=domain] [m=module[+instance][mgtObj=managedObject [property=property [propInst=propertyInstance] [qualifier=qualifier]]]] [severity=DIS|DWN|ERR|INF|IRR|OFF|WRN] [state=OPEN|CLOSED|FIXED] [ack=ACK|NOACK]
Parameters
a, domain, m, mgtObj, property, propInst, qualifier, severity, state, and ack.
Description
The setAlarmAction command sets a manual or delayed alarm action for all alarms under a domain of an agent or a list of agents.
Syntax
setAlarmAction a=host[:port][,host[:port]]* command=command [domain=domain] [m=module[+instance][mgtObj=managedObject [property=property [propInst=propertyInstance] [qualifier=qualifier]]]] [severity=DIS|DWN|ERR|INF|IRR|OFF|WRN] [state=OPEN|CLOSED|FIXED] [ack=ACK|NOACK]
To set up email alerts for an alarm, the command format can either be
command="email.sh:<email-id>:<message>" or
command="email:<email-id>:<message>"
Parameters
a, command, domain, m, mgtObj, property, propInst, qualifier, severity, state, and ack.