System Administrationmand(1m)


NAME

 mand - management network daemon

SYNOPSIS

 mand

DESCRIPTION

 

mand(1M) supports the management network (MAN) drivers and the failover management daemon (fomd(1M)) by providing the required network configuration. This configuration information includes host names, IP addresses, and netmasks. mand is also responsible for initializing and updating these respective fields in the platform configuration database (pcd(1M)) daemon as well as the in MAN driver on the system controller (SC).

mand is an SMS daemon running on both the main and spare SCs. Its role is set up by fomd.

This daemon is started automatically by the ssd(1M) daemon. Do not start it manually from the command line.

EXTENDED DESCRIPTION

 

SC-to-Domain and Domain-to-SC Internal Network (I1) data includes:

  • Network mask
  • SC host name
  • SC IP address
  • Domain[A-R] host name
  • Domain[A-R] IP address

SC-to-SC Internal Network (I2) data includes:

  • Network mask
  • SC 0 host name
  • SC 0 IP address
  • SC 1 host name
  • SC 1 IP address

SC External Community (C) data includes:

  • Community Failover IP address
  • Community physical interface name

EXIT STATUS

 

The following exit values are returned:

0
Successful completion.
>0
An error occurred.

FILES

 

The following configuration file is required:

/etc/opt/SUNWSMS/config/MAN.cf
This file includes the domain-to-SC, the SC-to-domain, and the SC-to-SC management network data as well as the community data for external access to the SC.

Do not manually modify the MAN.cf file.

ATTRIBUTES

 

See attributes(5) for descriptions of the following attributes.

Attribute TypesAttribute Values
AvailabilitySUNWSMSop

SEE ALSO

 

fomd(1m), pcd(1m), smsconfig(1m), ssd(1m)


SMS 1.4Go To TopLast Changed 19 September 2003