poweroff(1M) powers off the specified dual 48V power supply, fan tray, or board. If no arguments are specified and you have platform administrator privileges, the entire system, with the exception of the bulk power supplies, the fan trays, and the spare system controller (SC), powers off. If active domains are utilizing the component that is going to be powered off, a listing of those domains and an "Are you sure?" prompt is given by default.
Note When you power off a bulk power supply poweroff trips the circuit breaker. In that case the poweron command alone can not restore power. You must manually flip the breaker back on and then run poweron.If you do not have platform administrator privileges, the [location] command operand must be specified and the board must be assigned to a domain for which you have domain administrator or configurator privileges.
Note This command has no effect on the position of the virtual keyswitch. |