Sun N1 System Manager 1.2 Administration Guide

Hardware Sensor Attributes

For x86 servers, the management server software obtains the list of hardware sensor attributes to monitor through IPMI from the service processor of the server. For servers running the SPARC architecture, the ALOM interface is used. The list of hardware sensor attributes can vary from server to server, and between firmware versions. A sample listing for some servers and firmware versions is provided in this section. The attributes depend on the server type and on the number of CPUs that the server has.


Note –

Hardware disk failure and memory failure are not monitored in this version of the N1 System Manager.


The following example lists sensor names and descriptions for a Sun Fire V40z server with firmware version 2.1.0.16.


ambienttemp     Ambient air temp
bulk.v12-0-s0   Bulk 12V S0 voltage at CPU 0
bulk.v12-2-s0   Bulk 12V S0 voltage at CPU 2
bulk.v12-3-s0   Bulk 12V S0 voltage at CPU 3
bulk.v1_8-s0    Bulk 1.8V S0 voltage
bulk.v1_8-s5    Bulk 1.8V S5 voltage
bulk.v2_5-s0    Bulk 2.5V S0 voltage
bulk.v2_5-s0-dc Bulk 2.5V S0 voltage at DC
bulk.v2_5-s5    Bulk 2.5V S5 voltage
bulk.v3_3-s0    Bulk 3.3V S0 voltage
bulk.v3_3-s0-dc Bulk 3.3V S0 voltage at DC
bulk.v3_3-s3    Bulk 3.3V S3 voltage
bulk.v3_3-s5    Bulk 3.3V S5 voltage
bulk.v3_3-s5-dc Aux 3.3V S5 voltage at DC
bulk.v5-s0      Bulk 5V S0 voltage
bulk.v5-s0-dc   Bulk 5V S0 voltage at DC
bulk.v5-s5      Bulk 5V S5 voltage
bulk.v5-s5-dc   Bulk 5V S5 voltage at DC
cpu0.dietemp    CPU 0 Die temperature
cpu0.heartbeat  CPU 0 Heartbeat
cpu0.inlettemp  CPU 0 Inlet temperature
cpu0.memtemp    CPU 0 Memory temperature
cpu0.v2_5-s0    CPU 0 VDDA (2.5V) S0 voltage
cpu0.v2_5-s3    CPU 0 VDD (2.5V) S3 voltage
cpu0.vcore-s0   CPU 0 VCore S0 voltage
cpu0.vid        CPU 0 VID Selection
cpu0.vldt0      CPU 0 LDT0 voltage
cpu0.vtt-s3     CPU 0 DDR VTT S3 voltage
cpu1.dietemp    CPU 1 Die temperature
cpu1.heartbeat  CPU 1 Heartbeat
cpu1.inlettemp  CPU 1 Inlet temperature
cpu1.memtemp    CPU 1 Memory temperature
cpu1.v2_5-s0    CPU 1 VDDA (2.5V) S0 voltage
cpu1.v2_5-s3    CPU 1 VDD (2.5V) S3 voltage
cpu1.vcore-s0   CPU 1 VCore S0 voltage
cpu1.vid        CPU 1 VID Selection
cpu1.vldt1      CPU 1 LDT1 voltage
cpu1.vldt2      CPU 1 LDT2 voltage
cpu1.vtt-s3     CPU 1 DDR VTT S3 voltage
cpu2.dietemp    CPU 2 Die temperature
cpu2.heartbeat  CPU 2 Heartbeat
cpu2.inlettemp  CPU 2 inlet temperature
cpu2.temp       CPU 2 downwind temperature
cpu2.v2_5-s0    CPU 2 VDDA (2.5V) S0 voltage
cpu2.v2_5-s3    CPU 2 VDD (2.5V) S3 voltage
cpu2.vcore-s0   CPU 2 VCore S0 voltage
cpu2.vid        CPU-2 VID Selection
cpu2.vtt-s3     CPU 2 DDR VTT voltage
cpu3.dietemp    CPU 3 Die temperature
cpu3.heartbeat  CPU 3 Heartbeat
cpu3.inlettemp  CPU 3 inlet temperature
cpu3.temp       CPU 3 downwind temperature
cpu3.v2_5-s0    CPU 3 VDDA (2.5V) S0 voltage
cpu3.v2_5-s3    CPU 3 VDD (2.5V) S3 voltage
cpu3.vcore-s0   CPU 3 VCore S0 voltage
cpu3.vid        CPU-3 VID Selection
cpu3.vtt-s3     CPU 3 DDR VTT voltage
fan1.tach       Fan 1 measured speed
fan10.tach      Fan 10 measured speed
fan11.tach      Fan 11 measured speed
fan12.tach      Fan 12 measured speed
fan2.tach       Fan 2 measured speed
fan3.tach       Fan 3 measured speed
fan4.tach       Fan 4 measured speed
fan5.tach       Fan 5 measured speed
fan6.tach       Fan 6 measured speed
fan7.tach       Fan 7 measured speed
fan8.tach       Fan 8 measured speed
fan9.tach       Fan 9 measured speed
faultswitch     System Fault Indication
g0.vldt1        AMD-8131 PCI-X Tunnel 0 LDT1 voltage
g1.vldt1        AMD-8131 PCI-X Tunnel 1 LDT1 voltage
gbeth.temp      Gigabit ethernet local temperature
golem-v1_8-s0   AMD-8131 PCI-X Tunnel 1.8V S0 voltage
identifyswitch  Identify switch
scsibp.temp     SCSI Disk backplane temperature
scsifault       SCSI Disk Fault Switch
sp.temp         SP local temperature
vldt-reg1-dc    LDT Regulator 1 Voltage
vldt-reg2-dc    LDT Regulator 2 Voltage

The following example lists sensor names and descriptions for a Sun Fire V20z server with firmware version 2.1.0.16.


ambienttemp    Ambient air temp
bulk.v12-0-s0  Bulk 12v supply voltage (cpu0)
bulk.v12-1-s0  Bulk 12v supply voltage (cpu1)
bulk.v1_8-s0   Bulk 1.8v S0 voltage
bulk.v1_8-s5   Bulk 1.8v S5 voltage
bulk.v2_5-s0   Bulk 2.5v S0 voltage
bulk.v2_5-s5   Bulk 2.5v S5 voltage
bulk.v3_3-s0   Bulk 3.3v supply
bulk.v3_3-s3   Bulk 3.3v S3 voltage
bulk.v3_3-s5   Bulk 3.3v S5 voltage
bulk.v5-s0     Bulk 5v supply voltage
bulk.v5-s5     Bulk 5v S5 voltage
cpu0.dietemp   CPU 0 die temp
cpu0.heartbeat CPU 0 heartbeat
cpu0.memtemp   CPU 0 memory temp
cpu0.temp      CPU 0 low side temp
cpu0.v2_5-s0   CPU VDDA voltage
cpu0.v2_5-s3   CPU 0 VDDIO voltage
cpu0.vcore-s0  CPU 0 core voltage
cpu0.vid       CPU-0 VID output
cpu0.vldt1     CPU0 HT 1 voltage
cpu0.vldt2     CPU 0 HT 2 voltage
cpu0.vtt-s3    CPU 0 VTT voltage
cpu1.dietemp   CPU 1 die temp
cpu1.heartbeat CPU 1 heartbeat
cpu1.memtemp   CPU 1 memory temp
cpu1.temp      CPU 1 low side temp
cpu1.v2_5-s3   CPU 1 VDDIO voltage
cpu1.vcore-s0  CPU 1 core voltage
cpu1.vid       CPU-1 VID output
cpu1.vtt-s3    CPU 1 VTT voltage
fan1.tach      Fan 1 measured speed
fan2.tach      Fan 2 measured speed
fan3.tach      Fan 3 measured speed
fan4.tach      Fan 4 measured speed
fan5.tach      Fan 5 measured speed
fan6.tach      Fan 6 measured speed
faultswitch    Fault switch (source for eval)
g.vldt1        AMD-8131 PCI-X Tunnel HT 1 voltage
gbeth.temp     Gigabit ethernet temp
golem.temp     PCIX bridge temp
hddbp.temp     Disk drive backplane temp
identifyswitch Identify switch
ps.fanfail     Power Supply fan failure sensor
ps.tempalert   Power Supply too hot sensor
sp.temp        SP temp
thor.temp      AMD-8111 I/O Hub temp

Monitoring data is retrieved by the N1 System Manager from most these sensors.

For Sun Fire X4100 and Sun Fire X4200 servers, the following sensors are monitored:


Chassis Sensors:
sys.id               Indicates chassis type
sys.intsw            State of the Chassis Intrusion switch. When the chassis cover to 
                     the CPU area is opened this sensor logs an event
sys.psfail           LED indicator shows state of PS Fail / Rear LED 
                     on the front panel
sys.tempfail         LED indicator shows state of Over Temperature LED 
                     on the front panel
sys.fanfail          LED indicator shows state of Over Temperature LED 
                     on the front panel

Back Panel Sensors
bp.power             LED indicator shows state of the Power LED on the back panel
bp.locate            LED indicator shows state of the Locate LED on the back panel
bp.locate.btn        Monitors the state of the back panel locate button
bp.alert             LED indicator shows state of Alert LED on the back panel

Front Panel Sensors
fp.prsnt             Monitors the presence of the front panel board
fp.ledbd.prsnt       Monitors the presence of the front panel LED board
fp.usbfail           Monitors the front panel USB over current sensor
fp.power             LED indicator shows state of Power LED on the front panel
fp.locate            LED indicator shows state of Locate LED on the front panel
fp.locate.btn        Monitors the state of the front panel locate button
fp.alert             LED indicator shows state of Alert LED on the front panel

I/O Sensors
io.id0.prsnt         Monitors the 2-disk I/O board presence signal
io.id1.prsnt         Monitors the 4-disk I/O board presence signal
io.f0.prsnt          Monitors the physical presence of the rear blower
                     (Sun Fire X4200 chassis only)
io.f0.speed          Monitors the speed of the rear blower 
                     (Sun Fire X4200 chassis only)
io.f0.fail           LED indicator shows state of the I/O fan assembly
io.hdd0.fail         LED indicator shows state of the Hard Disk Drive 0 fault LED
io.hdd1.fail         LED indicator shows state of the Hard Disk Drive 1 fault LED
                     (Unused on the 2-disk Sun Fire X4100)
io.hdd2.fail         LED indicator shows state of the Hard Disk Drive 2 fault LED
                     (Unused on the 2-disk Sun Fire X4100)
io.hdd3.fail         LED indicator shows state of the Hard Disk Drive 3 fault LED
                     (Unused on the 2-disk Sun Fire X4100)

CPU 0 Sensors
p0.fail              LED indicator shows state of the CPU 0 fault LED
                     Illuminated for CPU voltage and temperature events
p0.d0.fail           LED indicator shows state of the CPU 0 DIMM 0 fault LED 
                     Illuminated in response to ECC errors
                     PAIR 0 includes this and p0.d1.fail, both LEDs in the same pair
                     will be illuminated at the same time when one indicates a fault
p0.d1.fail           LED indicator shows state of the CPU 0 DIMM 1 fault LED 
                     Illuminated in response to ECC errors
                     PAIR 0 includes this and p0.d0.fail, both LEDs in the same pair
                     will be illuminated at the same time when one indicates a fault
p0.d2.fail           LED indicator shows state of the CPU 0 DIMM 2 fault LED 
                     Illuminated in response to ECC errors
                     PAIR 1 includes this and p0.d3.fail, both LEDs in the same pair
                     will be illuminated at the same time when one indicates a fault
p0.d3.fail           LED indicator shows state of the CPU 0 DIMM 3 fault LED 
                     Illuminated in response to ECC errors
                     PAIR 1 includes this and p0.d2.fail, both LEDs in the same pair
                     will be illuminated at the same time when one indicates a fault

CPU 1 Sensors
p1.fail              Same as p0.fail, but for CPU 1
p1.d0.fail           Same as p0.d0.fail, but for CPU 1
p1.d1.fail           Same as p0.d1.fail, but for CPU 1
p1.d2.fail           Same as p0.d2.fail, but for CPU 1
p1.d3.fail           Same as p0.d3.fail, but for CPU 1

Power Supply Sensors
ps0.prsnt            Indicates whether Power Supply 0 is present
ps0.vinok            Indicates whether Power Supply 0 is connected to AC power
ps0.pwrok            Indicates whether Power Supply 0 is turned on and powering the system
ps1.prsnt            Indicates whether Power Supply 1 is present
ps1.vinok            Indicates whether Power Supply 1 is turned on and powering the system
ps1.pwrok            Indicates whether Power Supply 1 is turned on and powering the system

Fan Control Temperature Sensors
fp.t_amb             Monitors front panel ambient temperature
p0.t_core            Monitors CPU 0 core temperature
p1.t_core            Monitors CPU 1 core temperature

Other Temperature Sensors
mb.t_amb             Monitors ambient temperature from the internal temperature
                     sensor in the chip on the mainboard
pdb.t_amb            Monitors the ambient temperature of the power distibution board
io.t_amb             Monitors the ambient temperature from near the I/O area in the chassis

Mainboard Voltage Sensors
mb.v_bat             Monitors the 3V RTC battery on the mainboard
mb.v_+3v3stby        Monitors the 3.3V standby input that powers 
                     the service processor and other standby devices
mb.v_+3v3            Monitors the 3.3V main input that is active when the power is on
mb.v_+5v             Monitors the 5V main input that is active when the power is on
mb.v_+12v            Monitors the 12V main input that is active when the power is on
mb.v_-12v            Monitors the -12V main input that is active when the power is on
mb.+2v5core          Monitors the 2.5V core input that is active when the power is on
mb.+1v8core          Monitors the 1.8V core input that is active when the power is on
mb.+1v2core          Monitors the 1.2V core input that is active when the power is on

CPU 0 Voltage Sensors
p0.v_+1v5            Monitors the CPU 0 1.5V input
p0.v_+2v5core        Monitors the CPU 0 2.5V core input
p0.v_+1v2core        Monitors the CPU 0 1.2V core input

CPU 1 Voltage Sensors
p1.v_+1v5            Monitors the CPU 1 1.5V input 
p1.v_+2v5core        Monitors the CPU 1 2.5V core input
p1.v_+1v2core        Monitors the CPU 1 1.2V core input

Fan Presence Sensors (Sun Fire X4200 chassis only)
ft0.fm0.prsnt        Indicates the presence of Fan Tray 0, Fan Module 0
ft0.fm1.prsnt        Indicates the presence of Fan Tray 0, Fan Module 1
ft0.fm2.prsnt        Indicates the presence of Fan Tray 0, Fan Module 2
ft1.fm0.prsnt        Indicates the presence of Fan Tray 1, Fan Module 0
ft1.fm1.prsnt        Indicates the presence of Fan Tray 1, Fan Module 1
ft1.fm2.prsnt        Indicates the presence of Fan Tray 1, Fan Module 2

Fan Speed Sensors
ft0.fm0.f0.speed     Monitors speed of fan at Fan Tray 0, Fan Module 0, Fan 0
ft0.fm0.f1.speed     Monitors speed of fan at Fan Tray 0, Fan Module 0, Fan 1
                     (Sun Fire X4100 only)
ft0.fm1.f0.speed     Monitors speed of fan at Fan Tray 0, Fan Module 1, Fan 0
ft0.fm1.f1.speed     Monitors speed of fan at Fan Tray 0, Fan Module 1, Fan 1
                     (Sun Fire X4100 only)
ft0.fm2.f0.speed     Monitors speed of fan at Fan Tray 0, Fan Module 2, Fan 0
ft0.fm2.f1.speed     Monitors speed of fan at Fan Tray 0, Fan Module 2, Fan 1
                     (Sun Fire X4100 only)
ft1.fm0.f0.speed     Monitors speed of fan at Fan Tray 1, Fan Module 0, Fan 0
ft1.fm0.f1.speed     Monitors speed of fan at Fan Tray 1, Fan Module 0, Fan 1
                     (Sun Fire X4100 only)
ft1.fm1.f0.speed     Monitors speed of fan at Fan Tray 1, Fan Module 1, Fan 0
ft1.fm1.f1.speed     Monitors speed of fan at Fan Tray 1, Fan Module 1, Fan 1
                     (Sun Fire X4100 only)
ft1.fm2.f0.speed     Monitors speed of fan at Fan Tray 1, Fan Module 2, Fan 0
ft1.fm2.f1.speed     Monitors speed of fan at Fan Tray 1, Fan Module 2, Fan 1
                     (Sun Fire X4100 only)

For Sun Fire X2100 servers, only sensors describing fan speed, voltage, and temperature are used to retrieve data: Here is a list of sensors we monitored:


DDR 2.6V
CPU core Voltage
VCC 3.3V
VCC 5V
VCC 12V
Battery Volt
CPU TEMP
SYS TEMP
CPU FAN
SYSTEM FAN3
SYSTEM FAN1
SYSTEM FAN2