This section describes known firmware update issues.
Dual-core Sun Fire V20z and Sun Fire V40z servers require a 2.3.x and greater firmware revision. N1 System Manager does not prevent you from deploying firmware revisions below 2.3.x. Deploying firmware revisions below 2.3.x may result in issues with the server's service processor.
Workaround: Double check the firmware revision before updating.
If the ftp service is not enabled on the management server, firmware updates on ALOM-based servers fail with the following error message in the job output:
An exception occurred trying to update server-name. Please refer to the log file for more information. |