N1 Provisioning Server 3.1, Blades Edition, System Administration Guide

Hardware Abstraction Layer (HAL) Errors (ID 3000 through 3950)


3000
Missing attributes attribute-name
Description:

An attribute, such as an IP address for the server or a password, is missing in the CPDB.

Solution:

Use the device command to add the missing attribute to the CPDB. For details on how to use this command see the device man page.


3100
Network interface can only be configured by root.
Description:

The Network Virtual Interfaces (NVIs) cannot be created because the farm manager is not run as root.

Solution:

Ensure that the user has root access and retry the operation, or reissue the command that previously failed. Refer to the Solaris 8 documentation for details on root access.


3101
Solaris network interface is already in use.
Description:

The NVI intended to be created has already been created. This error can be caused by resources not being cleared up completely after a failed farm operation.

Solution:

Refer to Chapter 7, Troubleshooting for details on how to clear up NVIs and such resources.


3102
ifconfig failed on Solaris
Description:

ifconfig is a standard Solaris command. Failure to issue this command implies some misbehavior in the operating environment.

Solution:

Ensure that the Solaris software has been set up properly.


3103
unknown exit code from ifconfig
Description:

ifconfig is a standard Solaris command. Failure to issue this command implies some misbehavior in the operating environment.

Solution:

Ensure that the Solaris software has been set up properly.


3202
Login/passwd incorrect
Description:

Cannot log into a device, such as a server.

Solution:

Ensure that the user names and passwords on the database are current.


3204
Operation not supported on Solaris
Description:

Internal error.

Solution:

Contact http://sun.com/service/contacting/index.html for assistance.


3300
methodname The MAC address for key not found on device
Description:

The MAC address for the device is missing.

Solution:

This message is associated with the farm's WML. Contact http://sun.com/service/contacting/index.html for assistance.


3500
Warning: Cannot initialize interfaces on ifname (error)
Description:

The system is unable to bring up an interface, such as a card or driver.

Solution:

Contact http://sun.com/service/contacting/index.html for assistance.


3600
SQLException: exception
Description:

Database error.

Solution:

Contact http://sun.com/service/contacting/index.html for assistance.


3700
This feature is not supported.
Description:

Internal error.

Solution:

Contact http://sun.com/service/contacting/index.html for assistance.


3800
Physical Device is either null or not valid
Description:

Internal error.

Solution:

Contact http://sun.com/service/contacting/index.html for assistance.


3900
Invalid Power Controller Port
Description:

Inconsistency with the ports and the power controller specified in the database.

Solution:

Contact http://sun.com/service/contacting/index.html for assistance.


3950
Could not power down the specified port.
Description:

Power controller could not power down the device on a port.

Solution:

Check the physical device and ensure accessibility and its connection to the power controller.