SAY "Calling the peer"
|
Display this message on the screen of the dial-out machine.
|
TIMEOUT 10
|
Set the initial timeout to 10 seconds.
|
ABORT BUSY
|
Abort transmission if the modem receives this message from the opposite
peer.
|
ABORT 'NO CARRIER'
|
Abort transmission if the modem receives this message from the opposite
peer.
|
ABORT ERROR
|
Abort transmission if the modem receives this message from the opposite
peer.
|
REPORT CONNECT
|
Gather the CONNECT string from the modem. Print the
string.
|
"" AT&FB40S83.7=1&K44&J3X7S61.3=1S0=0S2=255
|
The letters in this line have the following meaning:
-
&F – Use factory default
-
B40 – Do asynchronous PPP conversion
-
S83.7=1 – Use data over speech bearer
-
&K44 – Enable CCP compression
-
&J3 – Enable MP
-
X7 – Report DCE side rates
-
S61.3=1 – Use packet fragmentation
-
S0=0 – No auto answer
-
S2=255 – Disable TIES escape
|
OK ATDI18882638234
|
Make an ISDN call. For multilink, the second call is placed to the same
telephone number, which is normally what is required by most ISPs. If the
remote peer requires a different second phone number, append “+nnnn.”. nnnn represents the
second phone number.
|
CONNECT \c
|
Wait for the CONNECT message
from the opposite peer's modem.
|
\r \d\c
|
Wait until the end of the CONNECT message.
|
SAY "Connected; running PPP\n"
|
Display this message on the screen of the dial-out machine.
|