The following procedure uses SCSI disk c1t4d0 in the example of configuring a SCSI device.
Become superuser.
Identify the device to be configured.
# cfgadm -al Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c0::dsk/c0t0d0 disk connected configured unknown c0::rmt/0 tape connected configured unknown c1 scsi-bus connected configured unknown c1::dsk/c1t3d0 disk connected configured unknown c1::dsk/c1t4d0 unavailable connected unconfigured unknown |
Configure the SCSI device.
# cfgadm -c configure c1::dsk/c1t4d0 |
Verify that the SCSI device is configured.
# cfgadm -al Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c0::dsk/c0t0d0 disk connected configured unknown c0::rmt/0 tape connected configured unknown c1 scsi-bus connected configured unknown c1::dsk/c1t3d0 disk connected configured unknown c1::dsk/c1t4d0 disk connected configured unknown |