JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Datacenter InfiniBand Switch 36 Topic Set
search filter icon
search icon

Document Information

Using This Documentation

Related Documentation

Documentation, Support, and Training

User's Guide

Installing the Switch

Understanding Switch Specifications

Routing Service Cables

Understanding InfiniBand Cabling

Preparing for Installation

Verify Shipping Carton Contents

Route the InfiniBand Cables

Install the Switch in the Rack

Powering On the Switch

Connecting InfiniBand Cables

Verifying the InfiniBand Fabric

Administering the Switch

Troubleshooting the Switch

Understanding Administrative Commands

Monitoring the Hardware

Monitoring the InfiniBand Fabric

Monitoring the Subnet Manager

Controlling the Hardware

Controlling the InfiniBand Fabric

Controlling the Subnet Manager

Servicing the Switch

Replaceable Components

Servicing Power Supplies

Servicing Fans

Servicing InfiniBand Cables

Servicing the Battery

Firmware Upgrades

Remote Management

Understanding Oracle ILOM on the Switch

Oracle ILOM Overview

Supported Features

Understanding Oracle ILOM Targets

Installing the Oracle ILOM Firmware

Firmware Delivery

Acquire the Oracle ILOM Firmware Version 1.1.3

Install the Oracle ILOM Firmware Version 1.1.3

Administering Oracle ILOM (CLI)

CLI Overview

Accessing Oracle ILOM From the CLI

Switching Between the Oracle ILOM Shell and the Linux Shell

Monitoring Oracle ILOM Targets (CLI)

Controlling Oracle ILOM Targets (CLI)

Upgrading the Switch Firmware Through Oracle ILOM (CLI)

Administering Oracle ILOM (Web)

Web Interface Overview

Access Oracle ILOM From the Web Interface

Monitoring Oracle ILOM Targets (Web)

Controlling Oracle ILOM Targets (Web)

Upgrading the Switch Firmware Through Oracle ILOM (Web)

Using the Fabric Monitor

Access the Fabric Monitor

Fabric Monitor Features

Accessing the Rear Panel Diagram

Accessing Status Pane Information

Control Panel Function

Monitoring Parameters and Status

Administering Oracle ILOM (SNMP)

SNMP Overview

Understanding SNMP Commands

SNMP Commands

V1 and V2c Protocol Command Format

V3 Protocol Command Format

Monitoring Oracle ILOM Targets (SNMP)

Performing Daily Tasks (SNMP)

Display the Date and Time (SNMP)

Display the Time Zone (SNMP)

Display the Aggregate Sensors State (SNMP)

Display Power Supply Status (SNMP)

Display Board-Level Voltages (SNMP)

Display Internal Temperatures (SNMP)

Display Fan Status (SNMP)

Display the Sensor Alarm State (SNMP)

Retrieving Entity Information

Display Oracle ILOM Sessions (SNMP)

Display the Oracle ILOM Event Log (SNMP)

Checking the Status of Services (SNMP)

Display the HTTP Service Status (SNMP)

Display the HTTPS Service Status (SNMP)

Display the SMTP Client Status (SNMP)

Display the NTP State (SNMP)

Display the NTP Servers (SNMP)

Verifying Other Aspects With Oracle ILOM (SNMP)

Display the Alert Properties (SNMP)

Display Oracle ILOM User Accounts (SNMP)

Display the Remote Log Hosts (SNMP)

Display the Network Management Configuration (SNMP)

Display Switch FRU ID (SNMP)

Display Power Supply FRU ID (SNMP)

Display the System Components (SNMP)

Display the Additional System Component Information (SNMP)

Display the Firmware Version (SNMP)

Display System Identifier (SNMP)

Controlling Oracle ILOM Targets (SNMP)

Performing General Tasks (SNMP)

Set the Date and Time (SNMP)

Set the Time Zone (SNMP)

Set the Network Time Protocol State (SNMP)

Set the Network Time Protocol Servers (SNMP)

Clear the Oracle ILOM Event Log (SNMP)

Set the Remote Log Hosts (SNMP)

Configure the SMTP Client (SNMP)

Set the Network Parameters (SNMP)

Set the System Identifier (SNMP)

Performing User Tasks (SNMP)

Add an Oracle ILOM User Account (SNMP)

Delete an Oracle ILOM User Account (SNMP)

Managing Other Aspects With Oracle ILOM (SNMP)

Set the HTTP Service State (SNMP)

Set the HTTPS Service State (SNMP)

Enable Alerts to Send SNMP Traps (SNMP)

Enable Alerts to Send PETs (SNMP)

Enable Alerts to Send Email Alerts (SNMP)

Modify Alert SNMP Version (SNMP)

Disable Alerts (SNMP)

Administering Hardware (IPMI)

ipmitool Overview

Display the Sensors' State (IPMI)

Display the Sensor Information (IPMI)

Display the System Event Log (IPMI)

Display FRU ID Information (IPMI)

Display Switch Status LED States (IPMI)

Enable the Locator LED (IPMI)

Disable the Locator LED (IPMI)

Understanding Oracle ILOM Commands

cd Command

create Command

delete Command

dump Command

exit Command (ILOM)

help Command (ILOM)

load Command

reset Command

set Command

show Command

version Command (ILOM)

Reference

Understanding Hardware Commands

Linux Shells for Hardware Commands

chassis_led Command

checkboot Command

checkguidfilesftree Command

checkpower Command

checktopomax Command

checkvoltages Command

connector Command

dcsport Command

disablecablelog Command

disablelinklog Command

disablesm Command

disableswitchport Command

enablecablelog Command

enablelinklog Command

enablesm Command

enableswitchport Command

env_test Command

exit Command (Hardware)

generatetopology Command

getfanspeed Command

getmaster Command

getnm2type Command

getportstatus Command

help Command (Hardware)

ibdevreset Command

listlinkup Command

managementreset Command

matchtopology Command

setcontrolledhandover Command

setloghost Command

setmsmlocationmonitor Command

setsmpriority Command

setsubnetprefix Command

showfruinfo Command

showpsufru Command

showsmlog Command

showtemps Command

showtopology Command

showunhealthy Command

smconfigtest Command

version Command (Hardware)

Understanding InfiniBand Commands

Linux Shells for InfiniBand Commands

ibaddr Command

ibcheckerrors Command

ibchecknet Command

ibchecknode Command

ibcheckport Command

ibcheckportstate Command

ibcheckportwidth Command

ibcheckstate Command

ibcheckwidth Command

ibclearcounters Command

ibclearerrors Command

ibdatacounters Command

ibdatacounts Command

ibdiagnet Command

ibdiagpath Command

ibhosts Command

ibnetdiscover Command

ibnetstatus Command

ibnodes Command

ibportstate Command

ibroute Command

ibrouters Command

ibstat Command

ibstatus Command

ibswitches Command

ibsysstat Command

ibtracert Command

perfquery Command

saquery Command

sminfo Command

smpdump Command

smpquery Command

Understanding SNMP MIB OIDs

OID Tables Overview

Understanding the SUN-DCS-MIB MIB OIDs

SUN-HW-TRAP-MIB MIB OIDs

Understanding the SUN-ILOM-CONTROL-MIB MIB OIDs

Understanding the SUN-PLATFORM-MIB MIB OIDs

Understanding the ENTITY-MIB MIB OIDs

Index

Entity Information by Entity Description

In the following table, the entity information is sorted by the entity description. Use this table when you want information about a specific entity.


Note - The Oracle ILOM targets and their respective entity numbers change from firmware revision releases and switch configurations. The entity numbers provided in the following table are for the 1.3.0_1 version of the firmware and a standard configuration of the switch.



Note - Because the load put upon the switch varies within each installation, the temperatures and fan speeds vary with the load. The values provided are for a switch with minimal loading and serve only as a guideline.


Entity Description
Oracle ILOM Target
Entity No.
Target Type
Typical Value
1.8 VDC state
/SYS/MB/V_1.8VOK
14
Aggregate Sensor
1 (Deasserted)
1.8 VDC voltage
/SYS/MB/V_1.8V
13
Voltage Sensor
1784
12 VDC voltage
/SYS/MB/V_12V
7
Voltage Sensor
11965
2.5 VDC state
/SYS/MB/V_2.5VOK
12
Aggregate Sensor
1 (Deasserted)
2.5 VDC voltage
/SYS/MB/V_2.5V
11
Voltage Sensor
2527
3.3 VDC main voltage
/SYS/MB/V_3.3VMain
4
Voltage Sensor
3249
3.3 VDC standby voltage
/SYS/MB/V_3.3VStby
6
Voltage Sensor
3385
3.3 VDC state
/SYS/MB/V_3.3VMainOK
5
Aggregate Sensor
1 (Deasserted)
5 VDC state
/SYS/MB/V_5VOK
9
Aggregate Sensor
1 (Deasserted)
5 VDC voltage
/SYS/MB/V_5V
8
Voltage Sensor
5044
Administrative Linux shell
/SYS/Fabric_Mgmt
23
Container
N/A
Attention LED
/SYS/I_ATTENTION
52
Indicator
Off
Battery voltage
/SYS/MB/V_BAT
10
Voltage Sensor
3213
Change in cable connectivity state
/SYS/CABLE_CONN_STAT
33
Aggregate Sensor
1 (Deasserted)
Comprehensive Linux shell
/SYS/Platform_CLI
24
Container
N/A
Cooling redundancy state
/SYS/COOLING_REDUN
32
Aggregate Sensor
1 (Deasserted)
ECB voltage state
/SYS/MB/V_ECB
3
Aggregate Sensor
1 (Deasserted)
Fan 1 container
/SYS/FAN1
42
Rear Fan Module
N/A
Fan 1 present
/SYS/FAN1/PRSNT
43
Presence Sensor
2 (Asserted)
Fan 1 speed
/SYS/FAN1/TACH
44
Speed Sensor
12208
Fan 2 container
/SYS/FAN2
45
Rear Fan Module
N/A
Fan 2 present
/SYS/FAN2/PRSNT
46
Presence Sensor
2 (Asserted)
Fan 2 speed
/SYS/FAN2/TACH
47
Speed Sensor
11881
Fan 3 container
/SYS/FAN3
48
Rear Fan Module
N/A
Fan 3 present
/SYS/FAN3/PRSNT
49
Presence Sensor
2 (Asserted)
Fan 3 speed
/SYS/FAN3/TACH
50
Speed Sensor
12099
Front temperature
/SYS/MB/T_FRONT
18
Temperature Sensor
28
I4 1.2 VDC state
/SYS/MB/V_I41.2VOK
16
Aggregate Sensor
1 (Deasserted)
I4 1.2 VDC voltage
/SYS/MB/V_I41.2V
15
Voltage Sensor
1216
I4 boot state
/SYS/MB/BOOT_I4A
20
Fault Sensor
1 (Deasserted)
I4 temperature
/SYS/MB/T_I4A
21
Temperature Sensor
37
Locator LED
/SYS/I_LOCATOR
53
Indicator
Off
Monitoring Linux shell
/SYS/Switch_Diag
22
Container
N/A
Motherboard container
/SYS/MB
2
Motherboard
N/A
Overall cable connectivity state
/SYS/CABLE_ATTN
30
Aggregate Sensor
1 (Deasserted)
Overall cooling state
/SYS/COOLING_ATTN
28
Aggregate Sensor
1 (Deasserted)
Overall I4 state
/SYS/IBDEV_ATTN
29
Aggregate Sensor
1 (Deasserted)
Overall power state
/SYS/POWER_ATTN
26
Aggregate Sensor
1 (Deasserted)
Overall switch state
/SYS/CHASSIS_STATUS
25
Aggregate Sensor
1 (Deasserted)
Overall temperature state
/SYS/TEMP_ATTN
27
Aggregate Sensor
1 (Deasserted)
Power LED
/SYS/I_POWER
51
Indicator
On
Power redundancy state
/SYS/POWER_REDUN
31
Aggregate Sensor
1 (Deasserted)
Power supply 0 AC present
/SYS/PSU0/AC_PRESENT
37
Fault Sensor
2 (Asserted)
Power supply 0 container
/SYS/PSU0
34
Power Supply FRU
N/A
Power supply 0 fault
/SYS/PSU0/ALERT
36
Fault Sensor
1 (Deasserted)
Power supply 0 present
/SYS/PSU0/PRSNT
35
Presence Sensor
2 (Asserted)
Power supply 1 AC present
/SYS/PSU1/AC_PRESENT
41
Fault Sensor
2 (Asserted)
Power supply 1 container
/SYS/PSU1
38
Power Supply FRU
N/A
Power supply 1 fault
/SYS/PSU1/ALERT
40
Fault Sensor
1 (Deasserted)
Power supply 1 present
/SYS/PSU1/PRSNT
39
Presence Sensor
2 (Asserted)
Rear temperatures
/SYS/MB/T_BACK
17
Temperature Sensor
30
SP temperature
/SYS/MB/T_SP
19
Temperature Sensor
40
Switch container
/SYS
1
Sun Datacenter InfiniBand Switch 36
N/A
Related Information