Sun Management Center 4.0 Release Notes

Add-On Config Readers Bugs

es-validate Command Reports Inconsistent Version Numbers Between English and Other Language Installations (6331558)

Localization packages for Entry-Level Platform (ELP), Netra, Desktop/Workstation, and Workgroup Server add-on software are not updated in this release because no change is needed since the two previous releases.

Workaround: None.

PICL Might Not Interpret Some System Configuration Changes on Low-End and Midrange Systems (6243759)

This issue occurs in the ELP, Netra, and Desktop/Workstation config readers.

On Netra 240/440/T4, Sun Blade 100, and Sun Fire V240 servers that use Solaris 10 software, Platform Information and Control Library (PICL) might not interpret some system configuration changes after initialization, such as the bge1-bge3 drivers. The instances for these drivers are reflected in the output of the prtconf -v command but not in the output of the prtpicl -v command.

Workaround: Realign PICL with the prtconf utility by issuing the svcadm restart picl command.