0
|
FRU 0 Hot Swap
|
Discrete (0x6f), "Hot Swap" (0xf0)
|
Hot Swap Event for CP3060 FRU
|
Monitors FRU states as described in the ATCA spec
|
1
|
RTM HotSwap
|
Discrete (0x6f), "Hot Swap" (0xf0)
|
Hot Swap Event for RTM FRU
|
Monitors FRU states as described in the ATCA spec
|
2
|
Hotswap AMC 0
|
Discrete (0x6f), "Hot Swap" (0xf0)
|
Hot Swap Event for AMC FRU
|
Monitors FRU states as described in the ATCA spec
|
3
|
IPMB Physical
|
Discrete (0x6f), "IPMB Link" (0xf1)
|
Link Status of IPMB
|
State of IPMB A or B bus is reported by monitoring the READY signal on the IPMB isolator.
|
4
|
BMC Watchdog
|
Discrete (0x6f), "Watchdog 2" (0x23)
|
Watchdog state of BMC
|
N/A
|
5
|
CPU Temp1
|
Threshold (0x01), "Temperature" (0x01)
|
Internal die temperature of CPU
|
Power supplies/blade server shall be shut down
|
6
|
CPU Temp2
|
Threshold (0x01), "Temperature" (0x01)
|
Internal die temperature of CPU
|
Power supplies/blade server shall be shut down
|
7
|
Board Temp
|
Threshold (0x01), "Temperature" (0x01)
|
Blade server temperature: Ambient @ ADM1026
|
Power supplies/blade server shall be shut down
|
8
|
12.0V
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 12.0V power rail
|
If this voltage is out of spec or goes to zero, all other power rails will fail (Except STBY). CP3060 and the RTM will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: All DC/DC converters
|
9
|
5.0V
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 5.0V power rail
|
If this voltage is out of spec or goes to zero, most other power rails will fail. CP3060 will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: Most DC/DC converters
|
10
|
3.3V
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 3.3V power rail
|
If this voltage is out of spec or goes to zero, many components on CP3060 will not function. Therefore, CP3060 will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: Multiple support devices
|
11
|
3.3V STBY
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 3.3V STBY power rail
|
If this voltage is out of spec or goes to zero, CP3060 and the RTM will not function. The IPMC will also not function . Supplies: All I2C devices, IPMC domain
|
12
|
2.5V STBY
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 2.5V STBY power rail
|
If this voltage is out of spec or goes to zero, CP3060 and the RTM will not function. The IPMC will also not function . Supplies: IPMC domain
|
13
|
1.0V
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 1.0V power rail
|
If this voltage is out of spec or goes to zero, many components on CP3060 will not function. Therefore, CP3060 will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: Multiple support devices, Service Processor
|
14
|
1.2V CPU
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 1.2V CPU power rail
|
If this voltage is out of spec or goes to zero, the CPU or HOST will not function. If all other power rails are up, the Service processor and IPMC will still function. Supplies: CPU core
|
15
|
1.2V
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 1.2V power rail
|
If this voltage is out of spec or goes to zero, many components on CP3060 will not function. Therefore, CP3060 will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: Multiple support devices, Service Processor
|
16
|
1.5V
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 1.5V power rail
|
If this voltage is out of spec or goes to zero, many components on CP3060 will not function. Therefore, CP3060 will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: Multiple support devices
|
17
|
0.9V VTTL
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 0.9V VTTL power rail
|
If this voltage is out of spec or goes to zero, the CPU or HOST will not function. If all other power rails are up, the Service processor and IPMC will still function. Supplies: DDR DIMMs.
|
18
|
0.9V VTTR
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 0.9V VTTR power rail
|
If this voltage is out of spec or goes to zero, the CPU or HOST will not function. If all other power rails are up, the Service processor and IPMC will still function. Supplies: DDR DIMMs.
|
19
|
1.8V DDR2L
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 1.8V DDR2L power rail
|
If this voltage is out of spec or goes to zero, the CPU or HOST will not function. If all other power rails are up, the Service processor and IPMC will still function. Supplies: DDR DIMMs.
|
20
|
1.8V DDR2R
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 1.8V DDR2R power rail
|
If this voltage is out of spec or goes to zero, the CPU or HOST will not function. If all other power rails are up, the Service processor and IPMC will still function. Supplies: DDR DIMMs., multiple support devices
|
21
|
2.5V
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of VDD 2.5V power rail
|
If this voltage is out of spec or goes to zero, many components on CP3060 will not function. Therefore, CP3060 will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: Multiple support devices, Service Processor
|
22
|
1.2V STBY
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of 1.2V STBY power rail
|
If this voltage is out of spec or goes to zero, CP3060 and the RTM will not function. The IPMC will also not function . Supplies: All I2C devices, IPMC domain
|
23
|
AMC 12V
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of AMC 12V power rail
|
If this voltage is out of spec or goes to zero, the AMC slot will not function. If this voltage is zero and CP3060 is functioning correctly, this implies the IPMC has not enabled the AMC slot.
|
24
|
AMC 3.3V
|
Threshold (0x01), "Voltage" (0x02)
|
Voltage measurement of AMC 3.3V power rail
|
If this voltage is out of spec or goes to zero, the AMC slot will not function. If this voltage is zero and CP3060 is functioning correctly, this implies the IPMC has not enabled the AMC slot.
|
25
|
RTM Presence
|
Discrete (0x6f), "Entity Presence" (0x25)
|
Presence of RTM
|
Indicates if an RTM is connected to CP3060
|
26
|
Version change
|
Discrete (0x6f), "reserved" (0x2b)
|
Firmware update event
|
Reports event after the FW update/cold reset
|