A P P E N D I X  L

Netra SPARC T3-1BA Blade Server Sensor Map and Fault Isolation

This appendix defines the sensors for the Netra SPARC T3-1BA blade server, which is the next generation blade after the Sun Netra CP3260 ATCA blade server.


Netra SPARC T3-1BA Blade Server Sensor List

The sensor numbers and names are reported by the on-board IPMC processor via the ShMM, within the ATCA chassis.


TABLE L-1 Netra SPARC T3-1BA Blade Server Sensor List

Sensor Number

Sensor
Name

Sensor
Type

Sensor
Description

Fault Condition
if Sensor Out of Limit

0

FRU 0 Hot Swap

Discrete (0x6f), "Hot Swap" (0xf0)

Hot swap for blade server FRU

N/A

1

ARTM Hot Swap

Discrete (0x6f), "Hot Swap" (0xf0)

Hotswap for RTM FRU

N/A

2

IPMB Physical

Discrete (0x6f), "IPMB Link" (0xf1)

Link Status of IPMB

No reply from IPMB (A or B). State of IPMB A or B bus is reported by monitoring the READY signal on the IPMB isolator.

3

BMC Watchdog

Discrete (0x6f), "Watchdog 2" (0x23)

Watchdog state of BMC

N/A

4

CPU 0 Temp

Threshold (0x01), "Temperature" (0x01)

Internal die temperature of CPU

If this temperature goes beyond 110C, all power supplies will be shut down and all front panel LEDs are turned off. The blue LED on the RTM remains ON.

5

CPU 1 Temp

Threshold (0x01), "Temperature" (0x01)

Internal die temperature of CPU

If this temperature goes beyond 110C, all power supplies will be shut down and all front panel LEDs are turned off. The blue LED on the RTM remains ON.

6

Vbat

Threshold (0x01), "Voltage" (0x02)

Voltage measurement of 3.0 VBAT/STBY power rail

If this voltage is out of spec or goes to zero, the on blade server battery is bad or missing. The battery is not required for blade server or the ARTM to function correctly. Supplies: 3.3V STBY

7

3.3 V STBY

Threshold (0x01), "Voltage" (0x02)

Voltage measurement of 3.3V STBY power rail

If this voltage is out of spec or goes to zero, blade server and the RTM will not function. Supplies: All I2C devices, IPMC

8

12.0V

Threshold (0x01), "Voltage" (0x02)

Voltage measurement of 12.0V power rail

If this voltage is out of spec or goes to zero, all other power rails will fail (Except STBY). Blade server and the RTM will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: All DC/DC converters

9

5.0V

Threshold (0x01), "Voltage" (0x02)

Voltage measurement of 5.0V power rail

If this voltage is out of spec or goes to zero, most other power rails will fail. Blade server will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: Most DC/DC converters

10

3.3V MAIN

Threshold (0x01), "Voltage" (0x02)

Voltage measurement of 3.3V power rail

If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: Multiple support devices

11

B0 VDD 1.1V

Threshold (0x01), "Voltage" (0x02)

Voltage measurement of VDD 1.1V power rail

If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: multiple support devices, service processor.

12

B1 VDD 1.1V

Threshold (0x01), "Voltage" (0x02)

Voltage measurement of VDD 1.1V power rail

If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: multiple support devices, service processor.

13

B2 VDD 1.1V

Threshold (0x01), "Voltage" (0x02)

Voltage measurement of VDD 1.1V power rail

If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: multiple support devices, service processor.

14

B3 VDD 1.1V

Threshold (0x01), "Voltage" (0x02)

Voltage measurement of VDD 1.1V power rail

If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: multiple support devices, service processor.

15

RF CPU VDD 1.5V

Threshold (0x01), "Voltage" (0x02)

Voltage measurement of VDD 1.5V power rail

If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: Multiple support devices, service processor

16

VTT MO 0.75V

Threshold (0x01), "Voltage" (0x02)

Voltage

 

17

VDD MO 1.5V

Threshold (0x01), "Voltage" (0x02)

Voltage measurement of VDD 1.5V power rail

If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: Multiple support devices, service processor

18

VDD 1.5V

Threshold (0x01), "Voltage" (0x02)

Voltage measurement of VDD 1.5V power rail

If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: Multiple support devices, service processor

19

VDD 2.5V

Threshold (0x01), "Voltage" (0x02)

Voltage measurement of VDD 2.5V power rail

If this voltage is out of spec or goes to zero, many components on blade server will not function. Therefore, blade server will not function. The IPMC will be alive if 3.3V STBY is up. Supplies: Multiple support devices, service processor

20

Version change

Discrete (0x6f), "reserved" (0x2b)

Firmware update event

IPMC reports event after the FW update/cold reset.

21

System event

Discrete (0x6f, “System Event” (0x12)

Tracks IPMC resets.

Every time IPMC takes a reset, an event is sent to Shelf manager. This sensor supports SOL based NetConsole use.

22

P48V alarm

Discrete (0x6f, “System Event” (0x12)

Monitors the 48V rails.

Monitors the 48V rails and reports the state via state bits. IPMC shall directly read Power Module’s voltage registers to determine presence of power rails. If a voltage less than 38 volts, rail is considered to be absent.

  • 0x1 (Bit 0 set) Both rails absent.
  • 0x2 (Bit 1 set) Only Rail A is present.
  • 0x4 (Bit 2 set) Only Rail B is present.
  • 0x8 (Bit 3 set) Both Rail A and B are present.

23

Sys fw progress

Discrete (0x6f), "System Firmware Progress" (0x0f),

Monitors the system firmware progress states.

This sensor monitors the firmware progress. The system firmware sends the firmware progress events to the system event log by way of the IPMC.

24

Graceful reboot

Discrete (0x6f) "OEM reserved" (0xc0)

Monitors the state of aa graceful reboot.

This sensor logs events into the system event log when a graceful reboot timer starts, stops, or expires.

25

Slot power

Threshold (0x01), "Voltage" (0x02)

Tracks the power being consumed by the slot.

This sensor is for information purposes and does not generate any events. The nominal value range for this sensor is from 5 Watts to ~300 Watts. The nominal value is set at 150 Watts. This is not indicative of a typical usage. Power usage shall depend upon the state of the blade and state of the OS running.

26

Thermal trip

Discrete (0x6f, “System Event” (0x12)

Reports upper non-recoverable (UNC) threshold violation events.

This sensor sends event notice if UNC threshold is reached.