This section provides error messages and possible solutions for troubleshooting SCSI configuration problems. For more information on troubleshooting SCSI configuration problems, see cfgadm(1M).
cfgadm: Component system is busy, try again: failed to offline: device-path Resource Information ------------------ -------------------------- /dev/dsk/c1t0d0s0 mounted filesystem "/file-system" |
You attempted to remove or replace a device with a mounted file system.
Unmount the file system that is listed in the error message and retry the cfgadm operation.
cfgadm: Component system is busy, try again: failed to offline: device-path Resource Information ------------------ -------------------------- /dev/dsk/device-name swap area |
If you use the cfgadm command to remove a system resource, such as a swap device or a dedicated dump device, a similar error message is displayed if the system resource is still active.
Unconfigure the swap areas on the device that is specified and retry the cfgadm operation.
cfgadm: Component system is busy, try again: failed to offline: device-path Resource Information ------------------ -------------------------- /dev/dsk/device-name dump device (swap) |
You attempted to remove or replace a dump device that is configured on a swap area.
Unconfigure the dump device that is configured on the swap area and retry the cfgadm operation.
cfgadm: Component system is busy, try again: failed to offline: device-path Resource Information ------------------ -------------------------- /dev/dsk/device-name dump device (dedicated) |
You attempted to remove or replace a dedicated dump device.
Unconfigure the dedicate dump device and retry the cfgadm operation.