可以使用 prtconf 命令来显示有关 IB 设备的常规信息。例如:
$ prtconf pci, instance #0 pci15b3,5a44, instance #0 ibport, instance #253 ibport, instance #254 ibport, instance #255 . . . ib, instance #0 ioc, instance #243 ioc, instance #244 ioc, instance #245 ioc, instance #246 ioc, instance #247 ioc, instance #248 ibgen, instance #249 |
在前面的示例中,pci15b3,5a44 是指 IB HCA。
执行以下步骤可显示特定 IB 设备的信息。
成为超级用户。
显示 IB 光纤结构信息。
例如:
# cfgadm -a Ap_Id Type Receptacle Occupant Condition ib IB-Fabric connected configured ok hca:1730000008070 IB-HCA connected configured ok ib::1730000007F5198 IB-IOC connected configured ok ib::1730000007F5199 IB-IOC connected configured ok ib::1730000008070,0,hnfs IB-HCA_SVC connected configured ok ib::1730000008071,0,sdp IB-PORT connected configured ok ib::1730000008072,0,sdp IB-PORT connected configured ok ib::1730000008071,8001,ipib IB-VPPA connected configured ok ib::1730000008072,8001,ipib IB-VPPA connected configured ok ib::ibgen,0 IB-PSEUDO connected configured ok # |
在前面的示例输出中,组件的描述如下:
标识与端口 2 连接并且绑定至 sdp 服务的 IB 端口设备。
标识使用 p_key 值 0x8001 与端口 2 连接并且绑定至 ibd 服务的 IB VPPA 设备。
标识绑定至 hnfs 服务的 IB HCA_SVC 设备。
标识 IOC 设备。
标识伪设备。
显示特定 IB 设备的信息。
例如,对于 IB VPPA 设备,将显示以下信息:
# cfgadm -al -s "cols=ap_id:info" ib::1730000008072,8001,ipib Ap_Id Information ib::1730000008072,8001,ipib ipib # |
例如,对于 IB HCA 设备,将显示以下信息:
# cfgadm -al -s "cols=ap_id:info" hca::1730000008070 Ap_Id Information hca::1730000008070 VID: 0x15b3, PID: 0x5a44, #ports: 0x2, port1 GUID: 0x1730000008071, port2 GUID: 0x1730000008072 # |
前面的输出显示了端口号和端口的 GUID。