Configures the SIP connection. Not implemented in this release.
none
The following table describes attributes for the sip-link element.
Table 1–196 sip-link Attributes
Attribute |
Default |
Description |
---|---|---|
120 |
(optional) Specifies the number of seconds of inactivity allowed before the connection is closed. |
|
50 |
(optional) Specifies the maximum number of simultaneous write requests or connect requests, or both, that can be waiting to write on a link. |
|
10 |
(optional) Specifies the timeout in milliseconds for a single write operation. Allowed values are between 1 and 50. |
|
25 |
(optional) Specifies the number of retries allowed for a single write operation. Allowed values are between 1 and 25. |
The following table describes properties for the sip-link element.
Table 1–197 sip-link Properties
Property |
Default |
Description |
---|---|---|
5000 |
Specifies the maximum time a thread can wait to get an exclusive lock for a sip link. |